Absolute Maximum Ratings (Note 1)
Supply Voltage (V
CC
) −0.5V to +7.0V
DC Input Diode Current (I
IK
)
V
I
=
−0.5V −20 mA
V
I
=
V
CC
+ 0.5V +20 mA
DC Input Voltage (V
I
) −0.5V to V
CC
+ 0.5V
DC Output Diode Current (I
OK
)
V
O
=
−0.5V −20 mA
V
O
=
V
CC
+ 0.5V +20 mA
DC Output Voltage (V
O
) −0.5V to to V
CC
+ 0.5V
DC Output Source
or Sink Current (I
O
)
±
50 mA
DC V
CC
or Ground Current
(I
CC
or I
GND
)
±
200 mA
Storage Temperature (T
STG
) −65˚C to +150˚C
DC Latch-Up Source or
Sink Current
±
100 mA
Recommended Operating
Conditions
(Note 2)
Supply Voltage (V
CC
)
LVQ 2.0V to 3.6V
Input Voltage (V
I
) 0VtoV
CC
Output Voltage (V
O
) 0VtoV
CC
Operating Temperature (T
A
)
74LVQ −40˚C to +85˚C
Minimum Input Edge Rate (∆V/∆t)
V
IN
from 0.8V to 2.0V
V
CC
@
3.0V 125 mV/ns
Note 1: The “Absolute Maximum Ratings” are those values beyond which
the safety of the device cannot be guaranteed. The device should not be op-
erated at these limits. The parametric values defined in the Electrical Charac-
teristics tables are not guaranteed at the absolute maximum ratings. The
“Recommended Operating Conditions” table will define the conditions for ac-
tual device operation.
Note 2: Unused inputs must be held HIGH or LOW. They may not float.
DC Electrical Characteristics
Symbol Parameter
V
CC
(V)
T
A
=
+25˚C T
A
=
−40˚C to +85˚C Units Conditions
Typ Guaranteed Limits
V
IH
Minimum High Level
Input Voltage
3.0 1.5 2.0 2.0 V V
OUT
=
0.1V
or V
CC
− 0.1V
V
IL
Maximum Low Level
Input Voltage
3.0 1.5 0.8 0.8 V V
OUT
=
0.1V
or V
CC
− 0.1V
V
OH
Minimum High Level
Output Voltage
3.0 2.99 2.9 2.9 V I
OUT
=
−50 µA
3.0 2.58 2.48 V V
IN
=
V
IL
or V
IH
(Note 3)
I
OH
=
−12 mA
V
OL
Maximum Low Level
Output Voltage
3.0 0.002 0.1 0.1 V I
OUT
=
50 µA
3.0 0.36 0.44 V V
IN
=
V
IL
or V
IH
(Note 3)
I
OL
=
12 mA
I
IN
Maximum Input
Leakage Current
3.6
±
0.1
±
1.0 µA V
I
=
V
CC
, GND
I
OLD
Minimum Dynamic (Note 4)
Output Current
3.6 36 mA V
OLD
=
0.8V Max (Note 5)
I
OHD
3.6 −25 mA V
OHD
=
2.0V Min (Note 5)
I
CC
Maximum Quiescent
Supply Current
3.6 2.0 20.0 µA V
IN
=
V
CC
or GND
V
OLP
Quiet Output
Maximum Dynamic V
OL
3.3 0.5 0.8 V (Notes 6, 7)
V
OLV
Quiet Output
Minimum Dynamic V
OL
3.3 −0.5 −0.8
V
(Notes 6, 7)
V
IHD
Maximum High Level
Dynamic Input Voltage
3.3 1.9 2.0 V (Notes 6, 8)
V
ILD
Maximum Low Level
Dynamic Input Voltage
3.3 1.8 0.8 V (Notes 6, 8)
Note 3: All outputs loaded; thresholds on input associated with output under test.
Note 4: Maximum test duration 2.0 ms, one output loaded at a time.
Note 5: Incident wave switching on transmission lines with impedances as low as 75Ω for commercial temperature range is guaranteed for 74LVQ.
Note 6: Worst case package.
Note 7: Max number of outputs defined as (n). Data inputs are driven 0V to 3.3V; one output at GND.
Note 8: Max number of Data Inputs (n) switching. (n − 1) inputs switching 0V to 3.3V. Input-under-test switching: 3.3V to threshold (V
ILD
), 0V to threshold (V
IHD
),
f
=
1 MHz.
www.fairchildsemi.com 2