DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

FEATURES:
Compact 300W with 1U height Power Density: 12.5 watts/cu in
Safety Approvals to IEC/EN/UL60601-1 3rd Edition
Power Factor Corrected to EN61000-3-2 class D
Peak Power 600W within 500uS Duty Duration
Variable Fan Speed & Low Acoustical Noise
High Quality & Reliable Component Usage
Output Voltages from 12 ~ 52Vdc
3 - Mechanical Options
Full Range AC Input
PRODUCT SPECIFICATIONS:
Input Voltage: 90-264Vac full range, 47~63Hz.
Input Current: 5A at 90Vac.
Inrush Current: Max. 70A@230Vac & 35A@115Vac; cold start.
PFC: Power Factor Correction pass EN61000-3-2 class D.
Transient Response: Returns to within 1% in less than 2.5mS for a
50% load change and the peak transient does not excess 5%.
Overshoot: Turn-on & off overshoot < 5% over nominal voltage.
Efficiency: 86% typical @ 230V and full load.
Turn On Delay: 1 second maximum at 230 Vac.
Hold Up Time: 16mS min @ 120Vac. at 80% of full load.
Adjustability: Output user adjustable +/-5% minimum.
Fan Drive: 12VDC/300mA offering to drive an external fan.
Fan Fail (FF) Alarm: Designated as FF on pin 3 of CN3 is a open
collector output rated for 28VDC/5mA sink current maximum, it will
go high when a fan failure is detected.
Remote On-Off: Designated as INH on pin4 of CN3, requires a low
signal to inhibit output.
Power Supply On: Green LED designated as LED1 on the PCB.
Power Good: PG on CN3 goes high 100-500mS after DC regulation
and low at least 1mS before loss of regulation (Open collector).
Input Fusing Protection: Dual T5A/250V fuses inserted in primary.
Over-Power Protection: 110~140% of I-Max; Auto-recovery.
Short Circuit Protection: Trip without damage and auto-recovery.
Switching Frequency: PFC 50K~70K Hz; PWM 65K~75K Hz.
Over Voltage Protection: Unit latching down when output exceed
130% and recycle AC input to reset.
Over-Temperature Protection: Unit protected of excessive
operating ambient 110±5 , and automatic recovery.
Operating Temperature: 0 to 70 ambient, de-rating at 2.5% per
degree from 50 to 70.
Vibration: 5 ~ 50 Hz, acceleration ±7.35 m/s*s on X,Y and Z Axis.
Storage Temperature: -20 to 85 .
Operating Humidity: 5% to 90% RH, Non-condensing.
Storage Humidity: 5% to 95% RH, Non-condensing.
EMC: EN60601-1-2 class B conducted / radiated; EN61000-3-2,3;
IEC61000-4-2, 3, 4, 5, 6, 8, 11.
Safety Regulation: EN/ IEC/ UL60601-1 3
rd
edition.
Leakage Current: < 300uA @ 264Vac.
HI-POT Test: 1500 VAC input line to chassis (10mA DC cut off
current); Isolating 4000VAC primary to secondary windings;
Primary to core 1500VAC. All for 3 sec.
Grounding Test: Apply 25 A from ground pin of the three prong
plug to the far most earth. Max allowable resistance 0.1 ohm.
Warranty: 2 years.
MTBF: 100000 Hrs (according to MIL-HBK-217F) at 30 .
Cooling:
U Type: U-Chassis @300W max. with 25CFM forced airflow; 150W
convection.
E Type: Enclosed with rear side built-in fan @300W max.
F Type: U-Chassis with top built-in fan @300W max.
Enclosure:
U Type: 5(L) x 3.2(W) x 1.5(H) inches.
E Type: 6.5(L) x 3.2(W) x 1.6(H) inches.
F Type: 5(L) x 3.2(W) x 2(H)inches.
Burn in: 45 +/- 5 degree C for 1 hour @230Vac with full load.
Weight: Maximum U-Type weight is 500g.
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.
ULTRA LEVEL TECH CO., LTD.
We Supply the Power Customers Need ISO9001
http://www.ultralevel.com.tw Tel:+886-2-29180118 Fax:+886-2-29181465
CB
E Type (Enclosed with end built-in fan):
3.2(W) x 6.5(L) x 1.6(H) inches
U Type (U-Chassis only):
3.2(W) x 5(L )x 1.5(H) inches.
F Type (U-Chassis with top built-in fan ):
3.2(W) x 5(L) x 2(H) inches.
OUTPUT VOLTAGE / POWER RATING CHART: Measured at output power connector.
Note:
* PRL1103 series are designated as PRL1103x-y where x can be E (Enclosed Type with rear side built-in fan) or F (U-Chassis Type with top
side built-in fan) or U (U-Chassis), y can be 12, 15, 24, 36, 48.
* U Type: U-Chassis @300W max. with min. 25CFM forced airflow; 150W under convection cooling.
* E Type: Enclosed with rear side built-in fan @300W max.
* F Type: U-Chassis with top built-in fan @300W max.
* All output range are covered in agencies certification and the preset voltage will be set as standard models if any request is not preset
output then should contact us in advance.
* Ripple and noise is measured from 10KHZ to 20MHz bandwidth at output with parallel 0.1µF ceramic and 22µF electrolytic capacitors.
* Providing peak power to 600W within 500uS for all models, longer duty duration need contact manufacture.
* 1% minimum load is required to maintain the ripple and regulation.
* Output is fully isolated.
Input Connector (CN1):
U and F Type: Mating JST Part No. VHR-5N or equivalent (5pin, 3 used), or Terminal Block: Howder M3 screws 3 pin 6.35mm center Part No.
HD-601-3P; PCB Labeling: L=Line; N=Neutral; G=Chassis Ground .
E Type: IEC320 snap-in mounting type or Terminal Block: Howder HD-602-3P.
Output Connector (CN2):
Mating JST Part No. VHR-6N
Terminal block-Dinkle P830N, M5 screws.
Output Pin Assignment:
(See table in right).
Mounting Inserts:
6Paces M3. Maximum Penetration 3.8mm sees outline drawing for location.
Logic signal connector (CN3):
Mating JST XHP-4 or equivalent (CHYAO SHIUNN JS-2001-04);
Mating Pins: JST SXH-002T-P0.6 FOR AWG 30 to 26.
Fan driver connector (FAN1):
Mating connector is JST P/N XHP-3 (3 pins 0.98 pitch) or equivalent (CHYAO SHIUNN JS-2001-03).
Dinkle Molex
V+: Pin 2 V+: Pin 4 ~ 6
V-: Pin 1 V-: Pin 1 ~ 3
OUTLINE DRAWING:
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.
Model
Output
Range
Preset
Voltage
Max. Output Power
Regulation
Ripple
& Noise
Type U & E & F
(Forced fan flow)
Type U
(Convection)
PRL1103x-12 12 ~ 13.8V 12 V 300W 150W +/- 1% 1%
PRL1103x-15 14 ~ 16V 15 V 300W 150W +/- 1% 1%
PRL1103x-24 23 ~ 28V 24V 300W 150W +/- 1% 1%
PRL1103x-36 35 ~ 43V 36V 300W 150W +/- 1% 1%
PRL1103x-48 44 ~ 52V 48V 300W 150W +/- 1% 1%
ULTRA LEVEL TECH CO., LTD.
We Supply the Power Customers Need ISO9001
http://www.ultralevel.com.tw Tel:+886-2-29180118 Fax:+886-2-29181465
Copy Right Ultra Level Tech Co., Ltd 2015, All Right Reserved. Specifications subject to change without notice.
ULTRA LEVEL TECH CO., LTD.
We Supply the Power Customers Need ISO9001
http://www.ultralevel.com.tw Tel:+886-2-29180118 Fax:+886-2-29181465
U Type (U-Chassis only): 5(L) x 3.2(W) x 1.5(H) inches; Weight: 500g.
E Type (Enclosed with Rear Side built-in Fan): 6.5(L) x 3.2(W) x 1.6(H)inches; Weight: 650g.
81.28 [3.20]
165.10 [6.50]
114.30 [4.50] 6.35 [0.25]
68.58 [2.70] 44.52 [1.75]
64.77 [2.55]
8.26 [0.32]
40.64 [1.60]
19.05 [0.75]
12NEXT

Freelance Electronics
13197 Sandoval Street
Santa Fe Springs, CA 90670

Hours of Operation
Monday-Friday 7:30am-4:30pm PST
(Deadline for next day shipment 2:00pm PST)

Trustworthy Standards Serving the Electronic Components
Industry since 1986

Government Cage code#-1V4R6
Duns Number# 788130532
Certified Small Disadvantaged Business