Specifications and characteristics in brief
Rated voltage V
R
Surge voltage V
S
160 ... 350 V DC
1.1 V
R
Rated capacitance C
R
Capacitance tolerance
3.3 ... 220 µF
±20% M
Dissipation factor tan δ
(20 °C, 120 Hz)
V
R
≤ 250 V DC: tan δ = 0.20
V
R
≥ 350 V DC: tan δ = 0.25
Leakage current I
leak
(20 °C, 5 min)
Self-inductance ESL Diameter (mm) ≤ 12.5 16 18
ESL (nH) 20 26 34
Useful life
125 °C, V
R
, I
AC,R
> 2000 h
Requirements ∆C/C ≤ ±35% of initial value
tan δ ≤ 3 times initial specified limit
I
leak
≤ initial specified limit
Voltage endurance test
125 °C, V
R
2000 h
Post test requirements ∆C/C ≤ ±30% of initial value
tan δ ≤ 2 times initial specified limit
I
leak
≤ initial specified limit
Vibration resistance test To IEC 60068-2-6, test Fc:
Displacement amplitude 0.75 mm, frequency range 10 ... 2000 Hz,
acceleration max. 20 g, duration 3 × 2 h.
Capacitor rigidly clamped by the aluminum case.
IEC climatic category To IEC 60068-1:
V
R
≤ 250 V: 40/125/56 (40 °C/+125 °C/56 days damp heat test)
V
R
≥ 350 V: 25/125/56 (25 °C/+125 °C/56 days damp heat test)
Sectional specification IEC 60384-4
B43866
Up to 125 °C
Page 3 of 24Please read Cautions and warnings and