www.perkinelmer.com/opto
USA:
PerkinElmer Optoelectronics
44370 Christy St.
Fremont, CA 94538
Phone: (510) 979-6500
Fax: (510) 687-1140
Toll Free: (800) 775-6786
Europe:
PerkinElmer Optoelectronics GmbH
Wenzel-Jaksch-Str. 31
65199 Wiesbaden
Germany
Phone: +49 611 492 0
Fax: +49 611 492 369
Asia:
PerkinElmer Optoelectronics
47 Ayer Rajah Crescent #06-12
Singapore 139947
Phone: +65 775 2022
Fax: +65 775 1008
Description Nominal Range
Power 300 watts 175-305 watts
Current 22 amps (DC) 13-23 amps (DC)
Operating Voltage 13.5 volts (DC) 11.5-15 volts (DC)
Ignition Voltage 23 kilovolts (recommended minimum)
Temperature 150º C (maximum)
Lifetime* 1000 hours (500 hour warranty)
* End of lamp life is defined as 50% of initial output.
Operational Specifications
Output at Nominal Power
PE300B-10F and PE300B-10UV
Physical Specifications
Description Specification
Arc Gap .038 inch (0.96mm)
Reflector Geometry Ellipsoidal 1= X
2
/M
2
+Y
2
/N
2
Weight 150 grams
Window Diameter 1 inch (25.4 mm)
Focused Output
F= UV Filtered Output/ UV = UV Enhanced Output
Description PE300B-10F
Radiant Output* 65 watts
UV Output* 3.3 watts
IR Output* 32 watts
Visible Output* 6500 Lumens
Color Temperature 5900 Kelvin
Peak Instabilities 4%
Spot Size at Crossover .09” at 50% pts
Spot Size at Crossover .23” at 10% pts
*These values indicate total output in all directions.
Wavelengths = UV<390nm, IR>770nm, Visible 390nm to 770nm.
** Beam Geometry defined as half angle at 10% PTS after 01/100/1000 hours.
Notes
1. Lamp must not be operated with window facing upwards within
45º of vertical.
2. Seal temperature must not exceed 150º C.
3. Current/power regulated power supplies and PerkinElmer lamp
housing units are recommended.
4. Lamp must be operated within recommended current and power
range. Over powering may lead to arc instability, hard starting
and premature aging.
5. Hot mirror assembly is available for IR filtering.
6. CERMAX lamps are much safer lamps to use than their quartz
xenon arc lamp equivalents. However, caution must be practiced
when operating lamps because they are under high pressure,
require high voltage, reach temperatures up to 200º C, and their
IR and UV radiation can cause skin burns and eye damage.
Read hazard sheet included with each lamp shipment.
Dimensions
Dimensions in parentheses are in millimeters.
200 300 400 500 600 700 800 900 1000 1100