Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

0031.1673

Part # 0031.1673
Description FEU SOCKET 5X20/6.3X32 IP 40- Bulk
Category Microcircuit
Availability In Stock
Qty 195
Qty Price
1 - 40 $1.27768
41 - 81 $1.01634
82 - 122 $0.95826
123 - 163 $0.89050
164 + $0.79371
Manufacturer Available Qty
SCHURTER
Date Code: 0819
  • Shipping Freelance Stock: 195
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

SCHURTER AG Switzerland,
(+)++41-41 369 31 11 Fax (+)++41- 41 369 34 03 E-mail: contact@schurter.ch Internet: http.//www.schurter.ch
175
FUSEHOLDERS / SICHERUNGSHALTER 5 x 20 mm
for /
für
Order No./ Packaging /
Bestell-Nr. Verpackung
0031.8221
Fuseholder, black / packaged loose, 100 pieces /
G-Sicherungshalter, schwarz lose geschüttet à 100 Stück
0031.8222
Fuseholder, black / blister tray, 500 pieces /
G-Sicherungshalter, schwarz Flachmagazin à 500 Stück
0853.0551
Cover / Technical data see page 196 /
Abdeckhaube max. 1,6 W Technische Daten siehe Seite 196
Technical data
Rated voltage: 250 V
Rated current: 10 A
Rated power acceptance at ambient
air temperature T
a
23 °C:
without cover: 2,5 W
with cover: 2 W
Power acceptance at higher T
a
:
see derating curves
Take note of the information
on pages 139–143
Allowable ambient air temperatures
T
a
: –25 to +85 °C
Contact resistance: 5 m
Dielectric strength: > 3 kV, 50 Hz,
1 Min.*
Impuls withstand voltage
Û
1,2/50
: > 12 kV*
Insulation resistance
(500 V DC/1 Min.): > 10 M
Overvoltage category: I to III
Pollution degree: 1 to 3
Clearance and creepage distances:
> 4 mm*
Resistance to vibration:
Frequency range 10–500 Hz, cross-
over frequency 60 Hz,
< 60 Hz constant amplitude
of 0,75 mm,
> 60 Hz constant acceleration of 10 g,
according to IEC 60068-2-6, test Fc
Climatic category GPF according
to DIN 40040
Solderability: 235 °C/2 sec., accor-
ding to IEC 60068-2-58, test Td
Resistance to soldering heat:
260 °C/10 sec., according to
IEC 60068-2-20,test Tb
Materials:
socket: thermoplastic, UL 94V-0,
comparative tracking index CTI 250
clips: copper-alloy, tin-plated
* between live parts of different potentials
Technische Daten
Nennspannung: 250 V
Nennstrom: 10 A
Nenn-Leistungsaufnahme bei Um-
gebungstemperatur T
u
23 °C:
ohne Abdeckhaube: 2,5 W
mit Abdeckhaube: 2 W
Zul. Leistungsaufnahme bei höheren
T
u
: siehe Derating-Kurven
Beachten Sie die Informationen
auf Seiten 139–143
Zulässige Umgebungstemperaturen
T
u
: –25 bis +85 °C
Durchgangswiderstand: 5 m
Spannungsfestigkeit: > 3 kV, 50 Hz,
1 Min.*
Steh-Stossspannungsfestigkeit
Û
1,2/50
: > 12 kV*
Isolationswiderstand
(500 V DC/1 Min.): > 10 M
Überspannungskategorie: I bis III
Verschmutzungsgrad: 1 bis 3
Luft- und Kriechabstände:
> 4 mm*
Vibrationsfestigkeit:
Frequenzbereich 10–500 Hz,
Übergangsfrequenz 60 Hz,
< 60 Hz konstante Amplitude von
0,75 mm,
> 60 Hz konstante Beschleunigung
von 10 g, nach IEC 60068-2-6, Test Fc
Klimakategorie GPF nach
DIN 40040
Lötbarkeit: 235 °C/2 Sek., nach
IEC 60068-2-58, Test Td
Lötwärmebeständigkeit:
260 °C/10 Sek., nach IEC 60068-2-20,
Test Tb
Werkstoffe:
Sockel: Thermoplast, UL 94V-0
Kriechstromindex CTI 250
Clips: Kupferlegierung, verzinnt
* zwischen unter Spannung stehenden Teilen mit
unterschiedlichem Potential
low profile fuse block with insulation
walls
kleine Bauhöhe, Sockel mit hoch-
gezogenen Isolierwänden
Fuseholder
open design
Type OGN
for PCB
surface mounting
suitable for reflow and
vapour-phase soldering
G-Sicherungshalter
offene Bauart
Typ OGN
für Leiterplatten
Oberflächenmontage
geeignet für Reflow- und Dampf-
phasenlötung
Cover / Abdeckhaube
0853.0551
0031.8221/22
max. dimensions for removal of cover/
max. Mass beim Entfernen der Abdeckhaube
Approvals / Approbationen
SEV (10 A/250 V) UL (10 A/250 V)
VDE (10 A/250 V) CSA (10 A/250 V)
SEMKO (10 A/250 V)
Standards / Normen
IEC 60127-6 (formerly / früher IEC 257)
EN 60127-6 (formerly / früher EN 60257),
UL 512, CSA C22.2-39
Cover / Abdeckhaube
Solder pads /
Anschlussflächen
Blister tray package Flachmagazin-Verpackung
0.00
0.50
1.00
1.50
2.00
2.50
20 30 40 50 60 70 80 90
I << In
I = 0.7 In
I = 1.0 In
Ambient air temperature T
a
°C
Umgebungstemperatur T
u
°C
Admissible power acceptance in Watt /
zulässige Leistungsaufnahme in Watt
0.00
0.50
1.00
1.50
2.00
20 30 40 50 60 70 80 90
I << In
I = 0.7 In
I = 1.0 In
Derating curves / Derating-Kurven
without cover / ohne Abdeckhaube
with cover / mit Abdeckhaube
50 75 100
SCHURTER AG Switzerland,
(+)++41- 41 369 31 11 Fax (+)++41- 41 369 34 03 E-mail: contact@schurter.ch Internet: http.//www.schurter.ch
176
FUSEHOLDERS / SICHERUNGSHALTER 5 x 20/6,3 x 32 mm
for /
für
Fuseholder
Type FEU
panel mount, front side
fixing nut fastening
shocksafe category PC2
G-Sicherungshalter
Typ FEU
für Plattenmontage, von Frontseite,
Schraubbefestigung
Berührungsschutz Kategorie PC2
recessed fuse carrier /
zurückversetzte Renkverschlusskappe
for / für 5 x 20 mm
0031.1673 0031.1681
0031.1663
for / für 6,3 x 32 mm
0031.1661/0031.1666
solder terminals, tin-plated /
Lötanschlüsse, verzinnt
Panel mounting holes / Durchbrüche in Montageplatte
Panel thickness /
Plattendicke
Fixing nut, SW 14 /
Befestigungsmutter, SW 14
0031.1673
0031.1681
Order No./ Socket and fuse carrier must be ordered separately / suitable for fuse-links /
Bestell-Nr. Sockel und Renkverschlusskappe separat bestellen geeignet für G-Sicherungseinsätze
0031.1673 Socket, black / Sockel, schwarz
0031.1681
Socket, black, for recessed fuse carrier / 5 x 20 and / und 6,3 x 32 mm
Sockel, schwarz, für zurückversetzte Kappe
0031.1661 Fuse carrier, bayonet, black / Renkverschlusskappe, schwarz 6,3 x 32 mm
0031.1663 Fuse carrier, bayonet, black / Renkverschlusskappe, schwarz 5 x 20 mm
0031.1666 Fuse carrier, bayonet, grey / Renkverschlusskappe, grau 6,3 x 32 mm
Accessoires see page 196 / Zubehör siehe Seite 196
bayonet type fuse carrier, slotted
the FEU-version with recessed
fuse carrier meets tool-only
accessibility requirements of
medical equipment
standards
solder terminals, tin plated
degree of protection IP 40 from front
side, according to IEC 60529
suitable for equipment with protection
classes I and II according to IEC 60536
Renkverschlusskappe mit Schlitz
die FEU-Version mit zurückversetzter
Renkverschlusskappe erfüllt die Forde-
rungen betreffend Zugänglichkeit ver-
schiedener Normen medizinischer
Geräte
Lötanschlüsse verzinnt
Schutzgrad IP40 von Frontseite, nach
IEC 60529
geeignet für Geräte der Schutzklassen
I und II nach IEC 60536
Technical data
Rated voltage: 250 V
Rated current: 10 A
Rated power acceptance at ambient
air temperature T
a
23 °C
for fuse links
5 x 20: 4 W/6,3 x 32: 4 W
Power acceptance at higher T
a
:
see derating curves
Take note of the information
on pages 139–143
Allowable ambient air temperatures
T
a
for accessible parts:
–25 to +85 °C
Contact resistance: 5 m
Dielectric strength: > 4 kV, 50 Hz,
1 Min.*
Insulation resistance (500 V DC/1 Min):
> 10
3
M
Torque/Fixing nut:
max. 1,2 Nm
* between metal mounting plate and live parts
Technische Daten
Nennspannung: 250 V
Nennstrom: 10 A
Nenn-Leistungsaufnahme bei Um-
gebungstemperatur T
u
23 °C
für G-Sicherungseinsätze
5 x 20: 4 W/6,3 x 32: 4 W
Zul. Leistungsaufnahme bei höheren
T
u
: siehe Derating-Kurven
Beachten Sie die Informationen
auf Seiten 139–143
Zulässige Umgebungstemperaturen
T
u
für berührbare Teile:
–25 bis +85 °C
Durchgangswiderstand: 5 m
Spannungsfestigkeit: > 4 kV, 50 Hz,
1 Min.*
Isolationswiderstand (500 V DC/1 Min.):
> 10
3
M
Anzugsdrehmoment der Mutter:
max. 1,2 Nm
* zwischen Metall-Montageplatte und unter
Spannung stehenden Teilen
Approvals, Patents / Approbationen, Patente
SEV (10 A/250 V)* UL (20 A/250 V)
VDE (10 A/250 V)* CSA (16 A/250 V)
SEMKO (10 A/250 V)* CS Australia (10 A/250 V)
FIMKO (6,3 A/250 V)*
* only for / nur für 0031.1673/1661/1663/1666
Patents in U.S. (No. 4,072,385) and in further countries /
Patente in US (Nr. 4,072,385) und weiteren Ländern
VDE
Standards / Normen
IEC 60127-6 (formerly / früher IEC 257),
EN 60127-6 (formerly / früher EN 60257),
UL 512, CSA C22.2-39
MEDICAL GRADE
Ambient air temperature T
a
°C
Umgebungstemperatur T
u
°C
Admissible power acceptance
in Watt /
zulässige Leistungsaufnahme
in Watt
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
20 30 40 50 60 70 80 90
I << In
I = 0.7 In
I = 1.0 In
Derating curve / Derating-Kurve
for / für 5x20 mm
and / und 6,3x32 mm
50 75 100
SCHURTER AG Switzerland,
(+)++41-41 369 31 11 Fax (+)++41- 41 369 34 03 E-mail: contact@schurter.ch Internet: http.//www.schurter.ch
177
FUSEHOLDERS / SICHERUNGSHALTER 5 x 20/6,3 x 32 mm
for /
für
Fuseholder
Type FEU
panel mount, front side
fixing nut fastening
shocksafe category PC2
G-Sicherungshalter
Typ FEU
für Plattenmontage, von Frontseite,
Schraubbefestigung
Berührungsschutz Kategorie PC2
for / für 5 x 20 mm
0031.1653
0031.1663
for / für 6,3 x 32 mm
0031.1661/1666
solder terminals, tin-plated /
Lötanschlüsse, verzinnt
Panel mounting holes / Durchbrüche in Montageplatte
Panel thickness /
Plattendicke
Fixing nut, SW 14 /
Befestigungsmutter, SW 14
Order No./ Socket and fuse carrier must be ordered separately / suitable for fuse-links /
Bestell-Nr. Sockel und Renkverschlusskappe separat bestellen geeignet für G-Sicherungseinsätze
0031.1653
Socket, black /
5 x 20 and / und 6,3 x 32 mm
Sockel, schwarz
0031.1661
Fuse carrier, bayonet, black /
6,3 x 32 mm
Renkverschlusskappe, schwarz
0031.1663
Fuse carrier, bayonet, black /
5 x 20 mm
Renkverschlusskappe, schwarz
0031.1666
Fuse carrier, bayonet, grey /
6,3 x 32 mm
Renkverschlusskappe, grau
Accessoires see page 196 / Zubehör siehe Seite 196
bayonet type fuse carrier, slotted
solder terminals, tin plated
degree of protection IP 40 from front
side, according to IEC 60529
suitable for equipment with protection
classes I and II according to IEC 60536
Renkverschlusskappe mit Schlitz
Lötanschlüsse, verzinnt
Schutzgrad IP40 von Frontseite,
nach IEC 60529
geeignet für Geräte der Schutzklassen
I und II nach IEC 60536
Technical data
Rated voltage: 250 V
Rated current: 10 A
Rated power acceptance at ambient
air temperature T
a
23 °C
for fuse links
5 x 20: 4 W/6,3 x 32: 4 W
Power acceptance at higher T
a
:
see derating curves
Take note of the information
on pages 139–143
Allowable ambient air temperatures
T
a
for accessible parts:
–25 to +85 °C
Contact resistance: 5 m
Dielectric strength: > 4 kV, 50 Hz,
1 Min.*
Insulation resistance (500 V DC/1 Min):
> 10
3
M
Torque/Fixing nut:
max. 1,2 Nm
* between metal mounting plate and live parts
Technische Daten
Nennspannung: 250 V
Nennstrom: 10 A
Nenn-Leistungsaufnahme bei Um-
gebungstemperatur T
u
23 °C
für G-Sicherungseinsätze
5 x 20: 4 W/6,3 x 32: 4 W
Zul. Leistungsaufnahme bei höheren
T
u
: siehe Derating-Kurven
Beachten Sie die Informationen
auf Seiten 139–143
Zulässige Umgebungstemperaturen
T
u
für berührbare Teile:
–25 bis +85 °C
Durchgangswiderstand: 5 m
Spannungsfestigkeit: > 4 kV, 50 Hz,
1 Min.*
Isolationswiderstand (500 V DC/1 Min.):
> 10
3
M
Anzugsdrehmoment der Mutter:
max. 1,2 Nm
* zwischen Metall-Montageplatte und
unter Spannung stehenden Teilen
Approvals, Patents / Approbationen, Patente
SEV (10 A/250 V) UL (20 A/250 V)
VDE (10 A/250 V) CSA (16 A/250 V)
SEMKO (10 A/250 V) CS Australia (10 A/250 V)
Patents in U.S. (No. 4,072,385) and in further countries /
Patente in US (Nr. 4,072,385) und weiteren Ländern
VDE
Standards / Normen
IEC 60127-6 (formerly / früher IEC 257),
EN 60127-6 (formerly / früher EN 60257),
UL 512, CSA C22.2-39
Ambient air temperature T
a
°C
Umgebungstemperatur T
u
°C
Admissible power acceptance
in Watt /
zulässige Leistungsaufnahme
in Watt
0.00
0.50
1.00
1.50
2.00
2.50
3.00
3.50
20 30 40 50 60 70 80 90
I << In
I = 0.7 In
I = 1.0 In
Derating curve / Derating-Kurve
for / für 5x20 mm
and / und 6,3x32 mm
50 75 100