Bezeichnung :
description :
XS
A 15,5 max. mm
B 7,5 max. mm
C 10,0 ± 0,5 mm
D 4,5 ± 0,5 mm
E 17,5 max. mm
F 2,5 ± 0,5 mm
Wert / value Einheit / unit tol.
Leerlauf-Induktivität /
inductance
DC-Widerstand /
DC-resistance
Nennstrom /
nominal current
Nennspannung/
nominal voltage
33%
+25°C
1500 V, 50 Hz
5mA, 2 sec.
MST Version 1
05-12-27
Name Änderung / modification Datum / date
Würth Elektronik
..................................................................................
UL94V-2
Abstandhalter / spacer:
Freigabe erteilt / general release:
Kunde / customer
UL94V-0
Kleber / glue:
It is recommended that the temperature of the part does
..................................................................................
C
Schaltbild / schematic:
B
Elektrische Eigenschaften / electrical properties:
F Werkstoffe & Zulassungen / material & approvals
G
Eigenschaften / general specifications:
D
Prüfgeräte / test equipment:
I
DC
max.
±30%
http://www.we-online.com
Datum / date
..................................................................................
Unterschrift / signature
Kontrolliert / approved
D-74638 Waldenburg · Max-Eyth-Strasse 1 -3 · Germany · Telefon (+49) (0) 7942 - 945 - 0 · Telefax (+49) (0) 7942 - 945 - 400
Geprüft / checked
Class F Betriebstemp. / operating temperature: -40°C - + 125°C
Spezifikation für Freigabe / specification for release
DATUM / DATE : 2005-12-27
max.
V
AC
250
mΩ
3,0
Kunde / customer :
STROMKOMP. DROSSEL WE-CMB "NiZn"
COMMON MODE CHOKE WE-CMB "NiZn"
Artikelnummer / part number :
744841330
A
Mechanische Abmessungen / dimensions:
10 kHz / 5mA
@ 25°C
µH
L
O
30
R
DC
26
Übertemperatur / temperature rise: < 55 K
A
FLUKE PM 6306 für/for L
0
/L
N
U
N
E
Testbedingungen / test conditions:
typ.
Luftfeuchtigkeit / humidity:
not exceed 125°C under worst case operating conditions.
HP 34401 A für/for I
N
und/and R
DC
Klimabeständigkeit/ climatic class: 40/125/21Sockel / base: UL94V-0
Draht / wire:
Umgebungstemperatur / temperature:
Prüfspannung / testing voltage
N1
3
4
N2
C
E
B
A
1 2
4
RoHS
compliant
LF
This electronic component is designed and developed with the intention for use in general electronics equipments. Before incorporating the components into any equipments in the
field such as aerospace, aviation, nuclear control, submarine, transportation, (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public
information network etc. where higher safety and reliability are especially required or if there is possibility of direct damage or injury to human body. In addition, even electronic
component in general electronic equipments, when used in electrical circuits that require high safety, reliability functions or performance, the sufficient reliability evaluation-check for
the safety must be performed before use. It is essential to give consideration when to install a protective circuit at the design stage.
SEITE 1 VON 1