DELTA 06AR2D

Cross Number:

Item Description: SINGLE 250V 6A IEC SNAP-IN N/A-LUG - Trays

Qty Price
1 + $12.00000



Other Cross Reference

Manufacturer Date Code Qty Available Qty
DELTA 9937
  • Freelance Stock: 1
    Ships Immediately





Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

C2:0.1uF
C3:0.1uF
SW1
F
L
Cy
C1 R C2 C3
L
G
E
N
N
I
FIG. A
L1
Cy
G'
L2
A
N'
D
O
L
AR3/4 ONLY
AR1/4 WITHOUT POWER SW
L'
FIG. B
AR3D ONLY
R
F
SW1
L
Cy
C1
L
C3C2
G
E
N
N
I
Cy
L1
G'
D
A
O
N'
L2
L
L'
1. AR series is designed as a high performance, two-stage filter for
low impedance load with better noise attenuation than AK series
in low frequency applications such as switching power supplies.
2. Fuse holder designed for one IEC 5x20mm fuse. Safety interlock
prevents fuse removal with line plug inserted (Use only with 250V
fuse).
3. All part numbers are UL recognized, CSA certified and VDE
approved.
4. Switch electrical lifetime: 10,000 cycles.
Maximum inrush current: 50A.
1. Maximum leakage current each
line-to-ground @ 115VAC 60Hz: 0.25mA
@ 250VAC 50Hz: 0.45mA
2. Hipot rating (one minute)
line-to-ground: 2250VDC
line-to-line: 1450VDC
3. Operating frequency: 50/60Hz
4. Rated voltage: 115/250VAC
4-3
SERIES
SPECIFICATIONS
POWER ENTRY MODULE EMI FILTERS
INTRODUCTIONS
ELECTRICAL SCHEMATIC
PART NO. C1 (uF) L1 (mH) L2 (mH) Cy (pF) R ( )
03AR1/2/3 0.1 1.5 9
2200 1M
03AR2D/3D 0.033 9 1.5
06AR1/2/3 0.1 0.7 2.5
06AR2D/3D 0.015 2.5 0.7 3300 2.2M
06AR4 0.1 0.7 2.5
COMPONENTS
CURRENT FREQUENCY-MHz
RATING .15 .50 1.0 5.0 10 30
03AR 40 60 60 45 40 30
06AR 34 55 56 40 35 25
06AR2D,3D 34 60 60 45 40 30
03AR 6 45 55 50 45 40
06AR 5 25 60 50 45 35
06AR2D,3D 10 10 50 50 45 40
COMMON MODE (L-G) IN 50 OHM SYSTEM
DIFFERENTIAL MODE (L-L) IN 50 OHM SYSTEM
MINIMUM INSERTION LOSS IN dB
1. Single-pole UL, CSA & VDE approved, VDE-6A at 250VAC.
2. Double-pole UL, CSA & VDE approved, VDE-4A at 250VAC.
Electrical lifetime: 10,000 cycles.
Maximum inrush current: 50A.
3. Voltage selector SW -UL, CSA & VDE approved
Current rating: 10A at 125VAC; 5A at 250VAC.
DELTA PART NO. AR1 AR2 AR2D AR3 AR3D AR4
115VAC 6A 6A 6A 6A 6A 6A
RATED CURRENT
250VAC 6A 6A 4A 6A 4A 6A
IEC CONNECTOR
FUSE HOLDER
1212
POWER SWITCH SP DP SP DP
333
VOLTAGE SELECTOR SW REAR REAR REAR
ELECTRICAL SCHEMATIC FIG. A FIG. A FIG. B FIG. A FIG. B FIG. A
TYPE & RATED CURRENT
D
V
E
POWER ENTRY MODULE FILTERS
66.0
1.0
R0.04Max.
27.0
2.6 0.003
1.063 0.003
Suggested thickness of mounting
panel is from 0.04 to 0.07 inch
suggest mounting cutout
INCH
UNIT:
mm
AR1
AR3, AR3D
AR4(without power switch)
AR2, AR2D
2.24
56.9
2.57
65.3
1.15
29.2
N
G
L
67.3
2.65
55.1
2.17
1.059
26.9
G
2.60
66.0
115V
1.15
29.2
N L
G
67.3
2.65
I
O
16.5
0.65
G
1.059
26.9
26.9
1.059
L
G
N
G
29.2
1.15
N
O
L
I
2.65
67.3
2.38
55.1
60.5
2.17
65.3
2.57
4-4
MECHANICAL CONSTRUCTION
POWER ENTRY MODULE FILTERS

Freelance Electronics
13197 Sandoval Street
Santa Fe Springs, CA 90670

Hours of Operation
Monday-Friday 7:30am-4:30pm PST
(Deadline for next day shipment 2:00pm PST)

Trustworthy Standards Serving the Electronic Components
Industry since 1986

Government Cage code#-1V4R6
Duns Number# 788130532
Certified Small Disadvantaged Business