68
Dimensions are in inches and millimeters unless otherwise specified. Values in italics
are metric equivalents. Dimensions are shown for reference purposes only.
Specifications subject to change.
Corcom Product Guide
Catalog: 1654001
Issue Date: 06.2011
For email, phone or live chat, please go to
te.com/help
corcom.com
Multipurpose Power Line RFI Filter for Emission Control
S Series
S Series
Maximum leakage current each Line to Ground:
3 & 20A
60A
@120 VAC 60 Hz: .4 mA .75 mA
@250 VAC 50 Hz: .7 mA 1.25 mA
Hipot rating (one minute):
Line to Ground: 2250 VDC
Line to Line: 1450 VDC
Rated Voltage (max): 250 VAC
Operating Frequency: 50/60 Hz
Rated Current: 3 to 60A
Operating Ambient Temperature Range
(at rated current I
r
): -10°C to +40°C
In an ambient temperature (T
a
) higher than +40°C
the maximum operating current (I
o
) is calculated as
follows: I
o
= I
r
(85-Ta)/45
• C
ombines Line to
Ground interference rejection
filters with additional circuitry to reduce Line to
Line noise and transients
• Designed for use when equipment impedance at
RF frequencies is high
• Effective for use with switch-mode power supplies
• Effective when used to control emissions in
equipment using SCR and T2L circuits for
compliance with FCC Part 15, Subpart J and
EN55022, Level A, down to 150kHz
Ordering Information
20 V S 6
Input / Output Style
1 – .250 [6.3] spade terminals
6 – Threaded bolt
S
Series
Leakage current designation
V – Standard
C
urrent Rating
3, 6, 10, 20 or 60A
Specifications
UL Recognized
CSA Certified
VDE Approved
Available Part Numbers
3VS1
3VS1 20VS1
6VS1 20VS6
10VS1 60VS6
20VS1
Electrical Schematics
3, 6, 10VS
20VS
60VS