S1A/B - S1M/B
Document number: DS16003 Rev. 22 - 2
2 of 4
www.diodes.com
October 2011
© Diodes Incorporated
S1A/B - S1M/B
Maximum Ratings @T
A
= 25°C unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitance load, derate current by 20%.
Characteristic Symbol
S1
A/AB
S1
B/BB
S1
D/DB
S1
G/GB
S1
J/JB
S1
K/KB
S1
M/MB
Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
R
50 100 200 400 600 800 1000 V
RMS Reverse Voltage
V
R
RMS
35 70 140 280 420 560 700 V
Average Rectified Output Current @ T
T
= 100°C I
O
1.0 A
Non-Repetitive Peak Forward Surge Current
8.3ms Single half sine-wave superimposed on rated load
I
FSM
30 A
Thermal Characteristics
Characteristic Symbol Value Unit
Typical Thermal Resistance, Junction to Terminal (Note 4)
R
JT
30
°C/W
Operating and Storage Temperature Range
T
J,
T
STG
-65 to +150
°C
Electrical Characteristics @T
A
= 25°C unless otherwise specified
Characteristic Symbol Min Typ Max Unit
Forward Voltage @ I
F
= 1.0A V
FM
- - 1.1 V
Peak Reverse Leakage Current @ T
A
= 25°C
at Rated DC Blocking Voltage @ T
A
= 125°C
I
RM
-
-
-
-
5.0
100
μA
Reverse Recovery Time (Note 5)
t
r
- 1.8 3.0
μs
Typical Total Capacitance (Note 6)
C
T
- 10 -
pF
Notes: 4. Thermal resistance junction to terminal, unit mounted on PC board with 5.0 mm
2
(0.013 mm thick) copper pads as heat sink.
5. Measured with I
F
= 0.5A, I
R
= 1.0A, I
RR
= 0.25A.
6. Measured at 1.0MHz and applied reverse voltage of 4.0V DC.
0
0.2
0.4
0.6
0.8
1.0
40 60 80 100 120 140 160 180
T , TERMINAL TEMPERATURE ( C)
Fig. 1 Forward Current Derating Curve
T
°
I, AVE
A
E F
WA
D
E
(A)
F
Resistive or
inductive load
0.4 0.8
0.01
0.1
10
V , INSTANTANEOUS FORWARD VOLTAGE (V)
Fig. 2 Typical Forward Characteristics
F
I , INS
AN
ANE
S F
WA
D
EN
(A)
F
1.0
01.61.2