222
MODULES
4000 Series
10W-33KV SINGLE OUTPUT DC/DC INDUSTRIAL
Features
• 0 to 100% adjustability.
• Voltage programmable.
• Voltage monitor.
• Remote on/off control.
• EMI/RFI shielding.
• Short circuit, reverse polarity protection.
• Arc protection.
Specifications
INPUT
Voltage +24Vdc (+20% to -5%).
OUTPUT
Power 10W.
Voltage See table.
Current See table.
Ripple See table.
Analog control 0 to 10 Volts = 0 to 100% output.
Voltage monitor 0 to 10 Volts = 0 to 100% output..
On/Off control On = 0 Volts or N.C.
Off = 5 Volts
Reference output 10 Volts (±0.5%).
ENVIRONMENTAL
Operating temperature –10°C to +60°C.
GENERAL
Dimensions 104 x 78.7 x 35.56 mm (4010 to 4200).
104 x 91.4 x 35.56 mm (4300 to 4330).
Weight 675g.
Packaging Fully encapsulated.
Case material Black anodised aluminum.
Input connector Molex 09-50-3071 (supplied).
Molex pins 08-50-0106 (supplied).
High voltage leads 30KV 22AWG (4010 to 4200).
40KV 20AWG (4300 to 4330).
OPTIONS
Negative output voltage Put “N” after model (eg 4300N).
PIN# FUNCTION
1 On/Off control
2 Ground/case
3 +24Volt input
4 10 Volt reference output
5 Programming voltage
6 Internal potentiometer
7 Voltage monitor
MODEL
NUMBER
OUTPUT OUTPUT*1
RIPPLE
VOLTAGE CURRENT
4010 0 to 1,000V 10mA 0.1%
4020 0 to 2,000V 5mA 0.1%
4030 0 to 3,000V 3.3mA 0.2%
4050 0 to 5,000V 2mA 0.1%
4070 0 to 7,000V 1.4mA 0.1%
4100 0 to 10,000V 1mA 0.1%
4120 0 to 12,000V 0.8mA 0.1%
4150 0 to 15,000V 0.67mA 0.1%
4200 0 to 20,000V 0.5mA 0.2%
4300*
2
0 to 30,000V 0.33mA 0.4%
4330*
2
0 to 33,000V 0.30mA 0.2%
Note: 1. At maximum rated output voltage.
2. No voltage monitor.
PROGRAMMING
VOLTAGE Apply 0-10V to pin 5 for 0-100% output.
RESISTANCE
Connect potentiometer to pin 4 (reference voltage),
connect wiper arm to pin 5, and connect
potentiometer to the ground.
MANUAL Connect pin 6 to pin 5, turn front panel pot for voltage
adjust.
Selection Tables