4
P O W E R T R A N S F O R M E R S
All Primaries 50/60 Hz.
Single Secondary
Insulation DIMENSIONS-INCHES
STANCOR Test
PART Primary Secondary RMS Termination Case Mounting Weight Agency
✳
Sec. NUMBER Volts Volts Amps. Style Volts Pri. Sec. H W D MW MD (lbs.) Certification
A P-8666 117 24.0 C.T. 12.0 NV 1500 Leads Leads 4.63 3.75 4.63 3.00 3.19 11.2
P-6469 117 25.2 1.00 A 1500 Leads Leads 2.00 3.25 2.13 2.81 - 1.40 -
P-8707 230 25.2 1.00 A 1500 Leads Leads 2.00 3.25 2.13 2.81 - 1.40 -
P-8180 117 25.2 C.T. 1.00 A 1500 Leads Leads 2.00 3.25 2.25 2.81 - 1.40 -
B P-8357 117 25.2 C.T. 2.00 A 1500 Leads Leads 2.63 4.00 2.25 3.56 - 2.20
P-8574 115/230 25.2 C.T. 2.00 A 1500 Leads Leads 2.63 4.00 2.25 3.56 - 2.20
P-8388 117 25.2 C.T. 2.80 A 1500 Leads Leads 2.63 4.00 2.25 3.56 - 2.20 -
P-8607‡ 117 26.0 C.T. 0.25 A 2500 Leads Leads 1.75 2.88 1.75 2.38 - 0.70 -
C P-8609 117 26.8 C.T. 1.00 A 1500 Leads Leads 2.00 3.25 2.13 2.81 - 1.30 -
P-8601 117 28.0 C.T. 0.175 A 1500 Leads Leads 1.38 2.38 1.50 2.00 - 0.35 -
P-8602 117 28.0 C.T. 0.30 A 1500 Leads Leads 1.75 2.88 1.63 2.38 - 0.60 -
P-8667 117 28.0 C.T. 1.00 A 1500 Leads Leads 2.00 3.25 2.13 2.81 - 1.40 -
D P-8668 117 28.0 C.T. 2.00 NV 1500 Leads Leads 3.13 2.50 2.50 2.00 2.19 2.90 -
P-8669 117 28.0 C.T. 4.00 NV 1500 Leads Leads 3.88 3.19 3.25 2.50 2.50 5.30 -
P-8670 117 28.0 C.T. 6.00 NV 1500 Leads Leads 4.25 3.44 3.50 2.75 2.63 7.00 -
P-8611 117 36.0 C.T. 0.135 A 1500 Leads Leads 1.38 2.38 1.38 2.00 - 0.35 -
E P-8612 117 36.0 C.T. 0.30 A 1500 Leads Leads 1.75 2.88 1.63 2.38 - 0.60 -
P-8613 117 36.0 C.T. 0.55 A 1500 Leads Leads 2.00 3.25 1.88 2.81 - 1.00 -
P-8671 117 36.0 C.T. 1.00 A 1500 Leads Leads 2.38 3.75 2.25 3.13 - 2.00 -
P-8672 117 36.0 C.T. 2.00 NV 1500 Leads Leads 3.50 2.81 2.75 2.25 2.13 3.50 -
F P-8673 117 36.0 C.T. 4.00 NV 1500 Leads Leads 4.19 3.50 2.88 2.75 2.38 6.00 -
P-8674 117 36.0 C.T. 6.00 NV 1500 Leads Leads 4.25 3.75 3.06 3.00 2.47 8.30 -
P-8542 115/230 40.0 C.T. 0.25 A 2500 Leads Leads 1.75 2.88 1.63 2.38 - 0.80 -
P-8566 115 40.0 C.T. 4.00 NV 1500 Leads Leads 3.81 3.19 3.50 2.50 2.88 6.40 -
P-8605‡‡ 117 48.0 C.T. 1.00 A 2500 Leads Leads 2.63 4.00 2.38 3.56 - 2.30 -
‡ Primary Tapped to Provide Secondary Voltages of 24.5 C.T., 27.5 C.T. or 29.0 C.T.
‡ ‡ Primary Tapped to Provide Secondary Voltages of 45 C.T., 48 C.T. 51 C.T. or 54 C.T.
Style A Style NV Style C
✳ Agency Certification Note: UL Recognized (File E68100, Guide #XPTQ2)
STANCOR Insulation DIMENSIONS-INCHES
PART Primary Secondary Test Termination Case Mounting Weight Agency
Sec. NUMBER Volts Volts Amps Style RMS Volts Primary Secondary H W D MW MD (lbs.) Certif.
G P-8684** 115 18.0 C.T. 1.00 NH 1500 Lugs Lugs 2.56 3.00 2.50 2.50 2.00 2.3 -
18.0 C.T. 1.00
** For 60 Hz. only
Single Primary, D u a l S e c o n d a r y