32 Snap Action Switch D2F
Specifications
■ Characteristics
Note: 1. Data shown are of initial value.
2. The dielectric strength shown in the table indicates a value for models with a separator.
3. For pin plunger models, the values are measured at the free position and total travel position. For the lever models, they are measured
at the total travel position.
■ Ratings
Note: 1. When using an inductive load or motor load, consult OMRON.
2.
The ratings apply under the following test conditions: Ambient Temperature = 20±2°C, Ambient Humidity = 65±5%, Operating frequency = 30 operations/min.
■ Approvals
UL Recognized, CSA Certified
Note: The rated values approved by each of the safety standards
(e.g.UL,CSA) may be different from the performance character-
istics individually defined in this catalog.
■ Contact Specifications
Note: Minimum applicable loads are indicated by N standard
reference values. This value represents the failure rate at a
60% (λ
60
) reliability level (JIS C5003).
The equation λ
60
=0.5 x 10
-6
/operations indicates that a failure
rate of 1/2,000,000 operations can be expected at a reliability
level of 60%.
Operating speed 1 to 500 mm/second (pin plunger models)
Operating frequency Mechanical: 200 operations per minute max.
Electrical: 30 operations per minute max.
Contact resistance General Purpose: 30 mΩ max. (Standard force versions)
50 mΩ max. (Low force versions)
Microload: 100 mΩ max.
Insulation resistance 100 MΩ min. at 500 VDC
Dielectric strength (See note 2) 600 VAC, 50/60 Hz for 1 minute between terminals of same polarity
1,500 VAC, 50/60 Hz for 1 minute between current-carrying metal parts and ground, and between each
terminal and non-current-carrying metal parts
Vibration resistance (See note 3) Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Shock resistance (See note 3)
Destruction: 1,000 m/s
2
(approx. 100G) max.
Malfunction: 300 m/s
2
(approx. 30 g min.) max.
Degree of protection IEC IP40
Degree of protection against
electric shock
Class I
Proof tracking index (PTI) 175
Ambient operating temperature -25° to 65°C (at 60% RH) with no icing
Ambient operating Humidity 85% max. (for 5° to 35°C)
Service life
(Consult Omron for test conditions)
Mechanical: 1 million operations min. at 60 operations/minute.
Electrical: 30,000 operations min. at 30 operations/minute.
Weight Approx. 0.5 g (pin plunger models)
Rated Voltage Resistive load
Microvoltage/current (D2F-01 models) General-purpose (D2F models)
Low force Standard Low force Standard
125 VAC ——1 A 3 A
30 VDC 0.1 A 0.1 A 0.5 A 2 A
Rated voltage
D2F
D2F-01
Standard
Force
Low Force
125 VAC 3 A 1A - - -
30 VDC 2 A 0.5 A 0.1 A
Item D2F D2F-01
Specification Crossbar
Material Silver alloy Gold alloy
Gap
(Standard value)
0.25 mm
Minimum Applicable Load
(See note)
100 mA at 5 VDC 1 mA at 5VDC