SBR140S3
1A SBR
®
Super Barrier Rectifier
Features Mechanical Data
• Low Forward Voltage Drop
Case Material: Molded Plastic, “Green” Molding
Compound.
• UL Flammability Classification Rating 94V-0
• Moisture Sensitivity: Level 1 per J-STD-020C
• Terminals: Matte Tin Finish annealed over
Alloy 42 leadframe. Solderable per MIL-STD-202,
Method 208
• Marking: See Page 3
• Ordering Information: See Page 3
NEW PRODUCT
• Low Reverse Leakage
• Excellent High Temperature Stability
• Patented Super Barrier Rectifier Technology
• Super Barrier Design
• Soft, fast switching capability
• 150ºC Operating Junction Temperature
• Molded Plastic SOD-323
• Lead Free/RoHS Compliant (Note 1)
• “Green” Device (Note 3)
Maximum Ratings @ T
A
= 25ºC unless otherwise specified
Single phase, half wave, 60Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
Characteristic Symbol Value Unit
Peak Repetitive Reverse Voltage
Working Peak Reverse Voltage
DC Blocking Voltage
V
RRM
V
RWM
V
RM
40
V
RMS Reverse Voltage
V
R(RMS)
28
V
Average Rectified Output Current T
C
=65°C
I
O
1
A
Non-Repetitive Peak Forward Surge Current
8.3ms Single Half Sine-Wave Superimposed on Rated Load
I
FSM
20 A
Maximum Thermal Resistance
Thermal Resistance Junction to Ambient (Note 2)
Thermal Resistance Junction to Ambient (Note 5)
R
θ
JA
R
θ
jA
473
407
°C/W
Operating and Storage Temperature Range
T
j
, T
STG
-65 to +150 ºC
Electrical Characteristics @ T
A
= 25ºC unless otherwise specified
Characteristic Symbol
Min Typ Max Unit
Test Condition
Reverse Breakdown Voltage (Note 4)
V
(BR)R
40 - - V
I
R
= 200 µA
Forward Voltage Drop
V
F
-
0.41
0.35
0.46
0.42
0.45
0.38
0.49
0.45
V
I
F
= 700mA, T
j
= 25ºC
I
F
= 700mA, T
j
= 150ºC
I
F
= 1A, T
j
= 25ºC
I
F
= 1A, T
j
= 150ºC
Leakage Current (Note 4)
I
R
-
8
3
10
4
15
9
30
12
µA
mA
µA
mA
V
R
= 10V, T
j
= 25 ºC
V
R
= 10V, T
j
= 150 ºC
V
R
= 40V, T
j
= 25 ºC
V
R
= 40V, T
j
= 150 ºC
Notes:
1. RoHS revision 13.2.2003. High temperature solder exemption applied, see EU Directive Annex Note 7.
2. FR-4 PCB, 2 oz. Copper, minimum recommended pad layout per http://www.diodes.com/datasheets/ap02001.pdf.
3. Diodes Inc.’s “Green” policy can be found on our website at http://www.diodes.com/products/lead_free/index.php.
4. Short duration pulse test used to minimize self-heating effect.
5. Polymide PCB, 2 oz. Copper, minimum recommended pad layout pad layout per http://www.diodes.com/datasheets/ap02001.pdf.
________
SBR is a registered trademark of Diodes Incorporated.
SBR140 Rev. 2 - 2 1 of 3
www.diodes.com
June 2007
© Diodes Incorporated