Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

412D-5

Part # 412D-5
Description
Category RELAY
Availability Out of Stock
Qty 0
Qty Price
1 + $50.08900



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

©2003 TELEDYNE RELAYS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 412 Page 1
www.teledynerelays.com
412/1203/Q1
ESTABLISHED RELIABILITY
SERIES
412
ESTABLISHED RELIABILITY
TO-5 RELAYS
DPDT
DESCRIPTION
The TO-5 relay, originally conceived and developed by Teledyne, has become
one of the industr
y standards for low-level switching from dry circuit to 1
ampere. Designed expressly for high-density PC board mounting, its small size
and low coil power dissipation make the 412 relay one of the most versatile
ultraminiature relays available.
The following unique construction features and manufacturing techniques
provide excellent resistance to environmental extremes and overall high
reliability.
All welded construction.
Unique uni-frame design, providing high magnetic efficiency and
mechanical rigidity.
High force/mass ratios for resistance to shock and vibration.
Advanced cleaning techniques provide maximum assurance of internal
cleanliness.
Precious metal alloy contact material with gold plating assures excellent
high current and dry circuit switching capabilities.
The Series 412D and 412DD relays have internal discrete silicon diodes for
coil suppression and polarity reversal protection. The hybrid 412T relay
features an internal silicon suppression diode and transistor driver. This hybrid
package reduces required PC board floor space by reducing the number of
external components needed to drive the relay.
By virtue of its inherently low intercontact capacitance and contact circuit
losses, the 412 relay has proven to be an excellent ultraminiature RF switch
for frequency ranges well into the UHF spectrum. A typical RF application for
the TO-5 relay is in handheld radio transceivers, wherein the combined
features of good RF performance, small size, low coil power dissipation and
high reliability make it a preferred method of T-R switching (see Figure 1).
INTERNAL CONSTRUCTION
SERIES
DESIGNATION
RELAY TYPE
412 DPDT basic relay
412D DPDT relay with internal diode for coil suppression
412DD
DPDT relay with internal diodes for coil transient suppression and polarity
reversal protection
412T
DPDT relay with internal transistor driver and coil transient suppression
diode
UPPER
STATIONARY
CONTACT
LOWER
STATIONARY
CONTACT
MOVING
CONTACT
UNI-FRAME
ARMATURE
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
–65°C to +125°C
Vibration
(General Note 1)
30 g’s to 3000 Hz
Shock
(General Note 1)
75 g’s,
6 msec, half-sine
Acceleration 50 g’s
Enclosure Hermetically sealed
Weight 0.09 oz. (2.55g) max.
412 Page 2 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE ©2003 TELEDYNE RELAYS
www.teledynerelays.com
412/1203/Q1
ESTABLISHED RELIABILITY
SERIES 412
GENERAL ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Notes 2 & 3)
DETAILED ELECTRICAL SPECIFICATIONS (–65°C to +125°C unless otherwise noted) (Note 3)
Contact Arrangement 2 Form C (DPDT)
Rated Duty Continuous
Contact Resistance 0.1 ohm max. before life; 0.2 ohm max. after life at 1A/28Vdc (measured 1/8" from header)
Contact Load Ratings (DC)
(See Fig. 2 for other DC
resistive voltage/current ratings)
Resistive: 1 Amp/28Vdc
Inductive: 200 mA/28Vdc (320 mH)
Lamp: 100 mA/28Vdc
Low Level: 10 to 50 μA/10 to 50mV
Contact Load Ratings (AC)
Resistive: 250 mA/115Vac, 60 and 400 Hz (Case not grounded)
100 mA/115Vac, 60 and 400 Hz (Case grounded)
Contact Life Ratings
10,000,000 cycles (typical) at low level
1,000,000 cycles (typical) at 0.5A/28Vdc resistive
100,000 cycles min. at all other loads specified above
Contact Overload Rating 2A/28Vdc Resistive (100 cycles min.)
Contact Carry Rating Contact factory
Coil Operating Power 450 milliwatts typical at nominal rated voltage @ 25°C
Operate Time 2.0 msec max. at nominal rated coil voltage
Release Time 412 Series: 1.5 msec max. 412D, 412DD Series: 4.0 msec max. 412T Series: 7.5 msec max.
Contact Bounce 1.5 msec max.
Intercontact Capacitance 0.4 pf typical
Insulation Resistance 10,000 megohms min. between mutually isolated terminals
Dielectric Strength Atmospheric pressure: 500 Vrms/60Hz 70,000 ft.: 125 Vrms/60Hz
Negative Coil Transient (Vdc) 412D, 412DD, 412T 1.0 max
Diode P.I.V. (Vdc) 412D, 412DD, 412T 100 min.
412T
Transistor
Characteristics
Base Turn Off Voltage (Vdc) 0.3 min.
Emitter-base breakdown Voltage (BVEBO) (@25°C) (Vdc) 6.0 min.
Collector-base breakdown Voltage (BVEBO) (@25°C & lc = 100 μA) (Vdc) 75 min.
BASE PART
NUMBERS
(See Note 10 for full P/N example)
412-5
412D-5
412DD-5
412T-5
412-6
412D-6
412DD-6
412T-6
412-9
412D-9
412DD-9
412T-9
412-12
412D-12
412DD-12
412T-12
412-18
412D-18
412DD-18
412T-18
412-26
412D-26
412DD-26
412T-26
Coil Voltage (Vdc)
Nom. 5.0 6.0 9.0 12.0 18.0 26.5
Max. 5.8 8.0 12.0 16.0 24.0 32.0
Coil Resistance
(Ohms ±10% @25°C)
412, 412D, 412T (Note 4) 50 98 220 390 880 1560
412DD (Note 4) 39 78 220 390 880 1560
Coil Current (mAdc @25°C)
(412DD Series)
Min. 93.2 58.3 33.0 25.6 17.5 14.8
Max. 128.2 78.3 42.9 32.8 22.1 18.5
Coil Current (mAdc @25°C)
(412T Series)
(Note 7)
Min. 82.2 52.9 35.3 26.6 17.9 14.7
Max. 112.1 69.9 47.4 35.8 24.0 19.8
Pick-up Voltage (Vdc, Max.)
412, 412D 3.5 4.5 6.8 9.0 13.5 18.0
412DD 3.9 5.2 7.8 10.0 14.5 19.0
412T (Note 7) 3.5 4.5 6.8 9.0 13.5 18.0
Base Current to Turn On (mAdc, Max.) (412T Series) (Note 7) 3.00 2.04 1.36 1.03 0.68 0.50
Drop-out Voltage (Vdc)
412, 412D, 412T
Min. 0.14 0.18 0.35 0.41 0.59 0.89
Max. 2.3 3.2 4.9 6.5 10.0 13.0
412DD
Min. 0.6 0.7 0.8 0.9 1.1 1.4
Max. 2.8 3.4 5.3 6.5 10.0 13.0
PERFORMANCE CURVES
(NOTE 2)
0
.1
.2
.3
.4
10
20
30
40
50
60
70
.01 0.5 .1 .5 1.0
FREQUENCY (GHz)
TYPICAL RF PERFORMANCE
INSERTION LOSS
RETURN
LOSS
(VSWR)
ISOLATION ACROSS CONTACTS
ISOLATION ACROSS POLES
1.92
1.22
1.07
1.02
1.01
1.00
1.00
VSWR
300
250
200
150
100
50
0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
LOAD CURRENT (AMPS DC)
TYPICAL DC CONTACT RATING (RESISTIVE)
LOAD VOLTAGE (VDC)
FIGURE 1
FIGURE 2
dB
©2003 TELEDYNE RELAYS SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE 412 Page 3
www.teledynerelays.com
412/1203/Q1
ESTABLISHED RELIABILITY
DIMENSIONS ARE SHOWN IN INCHES (MILLIMETERS)
.370
(9.40)
DIA. MAX.
.335
(8.51)
DIA. MAX.
.270 (6.86) MAX.
+.002 (.05)
.017 (.43)
–.001 (.03)
DIA.
TRANSISTOR BASE
CONNECTION FOR
412T ONLY
10
5
19
46
82
37
WIRE LEAD: .75 (19.05) MIN.
PIN: .187 (4.75) ±.010 (.25)
(See Note 6)
TERMINAL LOCATIONS AND PIN NUMBERING (REF. ONLY)
(Viewed from Terminals)
.035 (.89)
± .010 (0.25)
.031 (.79)
± .003 (0.08)
36°±3°
TYP.
.200 (5.08)
± .010 (.25) DIA.
OUTLINE DIMENSIONS
GENERAL NOTES
1. Relay contacts will exhibit no chatter in excess of 10 μsec or transfer in excess of
1 μsec.
2. “Typical” characteristics are based on available data and are best estimates. No
on-going verification tests are performed.
3. Unless otherwise specified, parameters are initial values.
4. For reference only. Coil resistance not directly measurable at relay terminals due
to internal series semiconductor. 412DD and 412T only.
5. Unless otherwise specified, relays will be supplied with either gold-plated or
solder-coated leads.
6. The slash and characters appearing after the slash are not marked on the relay.
7. Limit Base Emitter current to 15 mAdc.
8. Applicable to all coil voltages. See Base current to turn on.
9. Screened HI-REL versions available. Contact factory.
10.
412 412DD
412D 412T
Vcc Vr
Notes:
Logic 1 activates the relay.
Logic 0 de-activates the relay.
Vcc = logic bias power.
Vr = coil energization voltage.
Pin 10
Pin 9
Pin 1
Logic element
1 = 0.50 to 3.00mA
0 = 0.3Vdc min.
SCHEMATIC DIAGRAMS
TYPICAL LOGIC INTERFACE
(See Note 8)
Teledyne Part Numbering System for
T
2
R
®
Established Reliability Relay
ER 412 Y M - 26 A / S Q
Established Reliability
Designator
Pad Option
(See Appendix)
Relay Series
Optional Ground Pin
(See Appendix)
Q= Solder-Coated Leads
G= Gold-Plated Leads
(Notes 5 and 6)
S= .187" leads
(Note 6)
Coil Voltage
Screening and Reliability
Level
Teledyne Part Numbering System for Military Qualified (JAN) Relays
J 412 Y M - 26 P L
Military (JAN)
Designator
Spreader Option
(See Appendix)
Relay Series
Optional Ground Pin
(See Appendix)
Terminal Variant
P = 0.187"
Coil Voltage
Screening and Reliability
Level
SCHEMATICS ARE VIEWED
FROM TERMINALS
SERIES 412
12NEXT