DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

145
TF-RELAYS
SMALL POLARIZED RELAY
WITH HIGH SENSITIVITY
TESTING
mm inch
7.8
.307
9
.354
14
.551
FEATURES
• High sensitivity:
80 mW Nominal operating power (Single
side stable 3-12 V type)
• Surge voltage withstand: 1500 V FCC
Part 68
• Minimal magnetic interference allows
high density mounting
• Sealed construction allows automatic
cleaning
• Self-clinching terminal also available
SPECIFICATIONS
Contact
Note:
1This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the ac-
tual load.
Characteristics
Remarks
* Specifications will vary with foreign standards certification ratings.
*1
Measurement at same location as "Initial breakdown voltage" section.
*2
By resistive method, nominal voltage applied to the coil; contact carrying current:
1 A.
*3
Nominal voltage applied to the coil, excluding contact bounce time.
*4
Nominal voltage applied to the coil, excluding contact bounce time without diode.
*5
Half-wave pulse of sine wave: 11 ms; detection time: 10
µ
s.
*6
Half-wave pulse of sine wave: 6 ms.
*7
Detection time: 10
µ
s.
*8
Refer to 4. Conditions for operation, transport and storage mentioned in Cautions
for use (Page 178).
Arrangement 2 Form C
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m
Contact material Gold-clad silver
Rating
Nominal switching
capacity (resistive load)
1 A 30 V DC, 0.5 A 125 V AC
Max. switching power
(resistive load)
30 W, 62.5 VA
Max. switching voltage 110 V DC, 125 V AC
Max. switching current 1 A
Min. switching capacity
1 10
µ
A 10 mV DC
Nominal
operating
power
Single side stable
80 mW (3 to 12 V DC)
140 mW (24 V DC)
260 mW (48 V DC)
1 coil latching
55 mW (3 to 12 V DC)
100 mW (24 V DC)
2 coil latching
110 mW (3 to 12 V DC)
200 mW (24 V DC)
Expected
life (min.
operations)
Mechanical (at 180 cpm) 10
8
Electrical (at 20 cpm)
1 A 30 V DC resistive load
2
×
10
5
0.5 A 125 V AC resistive load
10
5
Initial insulation resistance*
1
Min. 1,000 M
(at 500 V DC)
Initial
breakdown
voltage
Between open
contacts
750 Vrms for 1 min.
(Detection current: 10 mA)
Between contact and
coil
1,000 Vrms for 1 min.
(Detection current: 10 mA)
Between contact sets
1,000 Vrms for 1 min.
(Detection current: 10 mA)
FCC surge voltage between open
contacts
1,500 V
Temperature rise*
2
(at 20
°
C) Max. 50
°
C
Operate time [Set time]*
3
(at 20
°
C)
Max. 4 ms (Approx. 2 ms)
[Max. 4 ms (Approx. 2 ms)]
Release time [Reset time]*
4
(at 20
°
C)
Max. 4 ms (Approx. 1 ms)
[Max. 4 ms (Approx. 2 ms)]
Shock resistance
Functional*
5
Min. 490 m/s
2
{50 G}
Destructive*
6
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
7
176.4 m/s
2
{18G}, 10 to 55 Hz
at double amplitude of 3 mm
Destructive
294 m/s
2
{30G}, 10 to 55 Hz
at double amplitude of 5 mm
Conditions for oper-
ation, transport and
storage*
8
(Not freezing and
condensing at low
temperature)
Ambient
temperature
–40
°
C to +70
°
C
–40
°
F to +158
°
F
Humidity 5 to 85% R.H.
Unit weight Approx. 2 g .071 oz
ORDERING INFORMATION
Ex. TF 2 L H 3V
Contact arrangement Operating function Terminal shape Coil voltage(DC)
2:2 Form C Nil: Standard PC board terminal
H: Self-clinching terminal
Nil: Single side stable
L: 1 coil latching
L2: 2 coil latching
3,4.5,5,6,9,12,
24,48
*
V
*
48 V coil type: Single side stable only
Note: AgPd stationary contact types available for high resistance against contact sticking.
When ordering, please add suffix“-3”like TF2-12V-3.
TF
146
TYPES AND COIL DATA (at 20
°
C 68
°
F)
1. Single side stable
2. 1 Coil latching
3. 2 Coil latching
Notes:
1. Specified value of the pick-up, drop-out, set and reset voltage is with the condition of square wave coil pulse.
2. Standard packing: Tube: 50 pcs.; Case; 1,000 pcs.
3. In case of 5 V drive circuit, it is recommended to use 4.5 V type relay.
4. AgPd stationary contact types available for high resistance against contact sticking. When ordering, please add suffix "-3" like TF2-12V-3.
Part No.
Nominal
voltage,
V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Nominal
operating
current,
mA (
±
10%)
Coil
resistance,
(
±
10%)
Nominal
operating
power,
mW
Max.
allowable
voltage,
V DC
Standard PC
board terminal
Self-clinching
terminal
TF2-3 V TF2-H-3 V 3 2.25 0.3 26.7 112.5 80 4.5
TF2-4.5 V TF2-H-4.5 V 4.5 3.38 0.45 17.8 253 80 6.7
TF2-5 V TF2-H-5 V 5 3.75 0.5 16 312.5 80 7.5
TF2-6 V TF2-H-6 V 6 4.5 0.6 13.3 450 80 9
TF2-9 V TF2-H-9 V 9 6.75 0.9 8.9 1,012.5 80 13.5
TF2-12 V TF2-H-12 V 12 9 1.2 6.7 1,800 80 18
TF2-24 V TF2-H-24 V 24 18 2.4 5.8 4,100 140 36
TF2-48 V TF2-H-48 V 48 36 4.8 5.4 8,860 260 57.6
Part No.
Nominal
voltage,
V DC
Set voltage,
V DC (max.)
Reset voltage,
V DC (max.)
Nominal
operating
current,
mA (
±
10%)
Coil
resistance,
(
±
10%)
Nominal
operating
power,
mW
Max.
allowable
voltage,
V DC
Standard PC
board terminal
Self-clinching
terminal
TF2-L-3 V TF2-L-H-3 V 3 2.25 2.25 18.3 163.6 55 4.5
TF2-L-4.5 V TF2-L-H-4.5 V 4.5 3.38 3.38 12.2 368.2 55 6.7
TF2-L-5 V TF2-L-H-5 V 5 3.75 3.75 11 454.5 55 7.5
TF2-L-6 V TF2-L-H-6 V 6 4.5 4.5 9.2 654.5 55 9
TF2-L-9 V TF2-L-H-9 V 9 6.75 6.75 6.1 1,472 55 13.5
TF2-L-12 V TF2-L-H-12 V 12 9 9 4.6 2,618 55 18
TF2-L-24 V TF2-L-H-24 V 24 18 18 4.2 5,760 100 36
Part No.
Nominal
voltage,
V DC
Set voltage,
V DC (max.)
Reset voltage,
V DC (max.)
Nominal
operating
current,
mA (
±
10%)
Coil
resistance,
(
±
10%)
Nominal
operating
power,
mW
Max.
allowable
voltage,
V DC
Standard PC
board terminal
Self-clinching
terminal
TF2-L2-3 V TF2-L2-H-3 V 3 2.25 2.25 36.7 81.8 110 4.5
TF2-L2-4.5 V TF2-L2-H-4.5 V 4.5 3.38 3.38 24.4 184.1 110 6.7
TF2-L2-5 V TF2-L2-H-5 V 5 3.75 3.75 22 227.3 110 7.5
TF2-L2-6 V TF2-L2-H-6 V 6 4.5 4.5 18.3 327.3 110 9
TF2-L2-9 V TF2-L2-H-9 V 9 6.75 6.75 12.2 736.4 110 13.5
TF2-L2-12 V TF2-L2-H-12 V 12 9 9 9.2 1,309 110 18
TF2-L2-24 V TF2-L2-H-24 V 24 18 18 8.3 2,880 200 36
DIMENSIONS
mm inch
Standard PC board terminal
Self-clinching terminal
General tolerance:
±
0.3
±
.012
14
.551
7.8
.307
7.1
.280
9
.354
7.62
.300
3.5
.138
2.54
.100
0.5
.020
0.25
.010
7.8
.307
7.1
.280
7.62
.300
3.5
.138
2.54
.100
0.5
.020
0.25
.010
PC board pattern
(Copper-side view)
10.16
.400
7.62
.300
2.54
.100
2.54
.100
10-1.0 dia
10-.039 dia
Tolerance:
±
0.1
±
.004
Schematic (Bottom view)
Single side stable
(Deenergized condition)
1-coil latching
(Reset condition)
2-coil latching
(Reset condition)
Direction indication*
10 9 8 7 6
1 2 3 4 5
+
Direction indication*
+
10 9 8 7 6
1 2 3 4 5
Direction indication*
+
+
10 9 8 7 6
1 2 3 4 5
*Orientation stripe typical-located on top of relay.
TF
147
REFERENCE DATA
1. Maximum switching capacity 2. Life curve 3. Mechanical life
Tested sample: TF2-12V, 10 pcs.
30 100 200
1.0
0.5
0.4
0.3
0.2
Switching voltage,V
Switching current, A
DC load (cosϕ=1)
AC load (cosϕ=1)
Switching current, A
No. of operations, ×10
4
0 0.5 1.0
100
10
30 V DC resistive load
125 V AC resistive load
Max.
Min.
Max.
Min.
No. of operations, ×10
4
10 100 1,000 10,000
Ratio against the rated voltage %V
0
10
20
30
40
50
60
70
80
90
100
Pick-up voltage
Drop-out voltage
4.-(1) Electrical life (DC load)
Tested sample: TF2-12V, 6 pcs.
Condition: 1 A 30 V DC resistive load, 20 cpm
Change of pick-up and drop-out voltage Change of contact resistance
4.-(2) Electrical life (AC load)
Tested sample: TF2-12V, 6 pcs
Condition: 0.5 A 125 V AC resistive load, 20 cpm
Change of pick-up and drop-out voltage
Max.
Min.
Max.
Min.
No. of operations, ×10
4
Ratio against the rated voltage, %V
0510
10
20
30
40
50
60
70
80
90
100
15 20
Pick-up voltage
Drop-out voltage
No. of operations, ×10
4
Contact resistance, m
Max.
Min.
0510
10
20
30
40
50
60
70
80
90
100
15 20
Ratio against the rated voltage, %V
Max.
Min.
Max.
Min.
No. of operations, ×10
4
05
10
20
30
40
50
60
70
80
90
100
10
Pick-up voltage
Drop-out voltage
Change of contact resistance
5. Coil temperature rise
Tested sample: TF2-xxV
Measured portion: Inside the coil
Ambient temperature: 30
°
C 86
°
F
6. Operate/release time characteristics
Tested sample: TF2-12V, 5 pcs.
No. of operations, ×10
4
Contact resistance, m
Max.
Min.
05
10
20
30
40
50
60
70
80
90
100
10
Temperature rise, °C
Coil applied voltage, %V
Nominal coil voltage
1 A
1 A
0 A
0 100 110 120 130 140 150
10
20
30
40
50
60
70
1 A
3-12 V DC
24 V DC
48 V DC
Coil applied voltage, %V
0 80 90 100 110 120
Operate/release time, ms
1
2
3
4
5
6
Max.
Min.
Max.
Min.
Operate time
Release time
7. Set/reset time characteristics
Tested sample: TF2-L2-12V, 5 pcs.
8. Distribution of pick-up and drop-out voltage
Tested sample: TF2-12V, 50 pcs.
9. Distribution of set and reset voltage
Tested sample: TF2-L2-12V, 20 pcs.
Coil applied voltage, %V
0 80 90 100 110 120
1
2
3
4
5
6
Set/reset time, ms
Max.
Min.
Set time
Reset time
010
10
20
30
20 30 40 50 60 70 80 90 100
Quantity
Ratio against the rated voltage, %V
Drop-out
voltage
Pick-up
voltage
20100
5
10
30 40 50 60 70 80 90 100
Quantity
Ratio against the rated voltage, %V
Set voltage
Reset voltage
12NEXT