Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

S2EB-L2-24V

Part # S2EB-L2-24V
Description RELAY GEN PURPOSE 4PST 4A 24V
Category RELAY
Availability In Stock
Qty 15
Qty Price
1 - 3 $15.55310
4 - 6 $12.37178
7 - 9 $11.66482
10 - 12 $10.84004
13 + $9.66177
Manufacturer Available Qty
Aromat
  • Shipping Freelance Stock: 15
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

219
S-RELAYS
4 AMP POLARIZED HIGH
DENSITY RELAY WITH HIGH
SENSITIVITY
mm inch
28.0
1.102
12.0
.472
10.4
.409
FEATURES
• A variety of contact arrangements 2
Form A 2 Form B, 3 Form A 1 Form B,
4 Form A
• Latching types available
• High sensitivity in small size 100 mW
pick-up and 200 mW nominal operating
power
• High shock and vibration resistance
Shock: 50 G Vibration: 10 to 55 Hz at
double amplitude of 3 mm .118 inch
Wide switching range From 100
µ
A
100 mV DC to 4 A 250 V AC
• Low thermal electromotive force Ap-
prox. 3
µ
V
• Dual-In-Line packaging arrangement
• Amber types available
SPECIFICATIONS
Contacts
Coil (polarized) (at 20
°
C 68
°
F)
Characteristics (at 25
°
C 77
°
F 50% Relative humidity)
Arrangement
2 Form A 2 Form B,
3 Form A 1 Form B,
4 Form A
Initial contact resistance, max.
(By voltage drop 6 V DC 1 A)
50 m
Initial contact pressure Approx. 12 g .42 oz
Contact material Gold clad silver alloy
Electrostatic capacitance Approx. 3pF
Thermal electromotive force
(at nominal coil voltage)
Approx. 3
µ
V
Rating
(resistive)
Nominal switching capacity 4 A 250 V AC, 3 A 30 V DC
Maximum switching power 1,000 VA, 90 W
Maximum switching voltage
250 V AC, 30 V DC
(48 VDC at less than 0.5 A)
Max. switching current 4 A (AC), 3 A (DC)
Min. switching capacity**
1
100
µ
A 100 m V DC
Expected
life (min.
operations)
Mechanical (at 50 cps) 10
8
Electrical
(at 20 cpm)
4 A 250 V AC 10
5
3 A 30 V DC 2
×
10
5
Single side
stable
Minimum operating power Approx. 100 mW
Nominal operating power Approx. 200 mW
Latching
Minimum set and reset Approx. 100 mW
Nominal set and reset Approx. 200 mW
Max. operating speed
20 cpm for maximum load,
50 cps for low-level load
(1 mA 1 V DC)
Initial insulation resistance*
1
10,000 M
at 500 V DC
Initial
breakdown
voltage*
2
Between open contacts 750 Vrms
Between contact sets 1,000 Vrms
Between contacts and
coil
1,500 Vrms
Operate time*
3
(at nominal voltage)(at 20
°
C)
Max. 15 ms (Approx. 8 ms)
Release time (without diode)*
3
(at nominal voltage)(at 20
°
C)
Max. 10 ms (Approx. 5 ms)
Set time*
3
(latching)
(at nominal voltage)(at 20
°
C)
Max. 15 ms (Approx. 8 ms)
Reset time*
3
(latching)
(at nominal voltage)(at 20
°
C)
Max. 15 ms (Approx. 8 ms)
Initial contact bounce, max. 1 ms
Temperature rise
(at nominal voltage)(at 20
°
C)
Max. 35
°
C with nominal coil
voltage and at maximum
switching current
Shock resistance
Functional*
4
Min. 490 m/s
2
{50 G}
Destructive*
5
Min. 980 m/s
2
{100 G}
Vibration resistance
Functional*
6
176.4 m/s
2
{18 G}, 10 to 55 Hz
at double amplitude of 3 mm
Destructive
235.2 m/s
2
{24 G}, 10 to 55 Hz
at double amplitude of 4 mm
Conditions for operation,
transport and storage*
7
(Not freezing and condens-
ing at low temperature)
Ambient
temp.
–40
°
C to +65
°
C
–40
°
F to +149
°
F
Humidity 5 to 85% R.H.
Unit weight Approx. 8 g .28 oz
Notes:
**
1
This value can change due to the switching frequency, environmental conditions,
and desired reliability level, therefore it is recommended to check this with the ac-
tual load.
Remarks
* Specifications will vary with foreign standards certification ratings.
*
1
Measurement at same location as "Initial breakdown voltage "section
*
2
Detection current: 10mA
*
3
Excluding contact bounce time
*
4
Half-wave pulse of sine wave: 11ms; detection time: 10
µ
s
*
5
Half-wave pulse of sine wave: 6ms
*
6
Detection time: 10
µ
s
*
7
Refer to 5. Conditions for operation, transport and storage mentioned in
AMBIENT ENVIRONMENT (Page 61).
TYPICAL APPLICATIONS
Telecommunications equipment, data processing equipment,
facsimiles, alarm equipment, measuring equipment.
S
220
Ex.
Contact arrangement Classification of type
2: 2 Form A 2 Form B
3: 3 Form A 1 Form B
4: 4 Form A
EB: Amber sealed type
Operating function
Nil: Single side stable
L2: 2 coil latching
Coil voltage (DC)
3, 5, 6, 12, 24, 48 V
S 2 EB L2 48V
(Notes) 1. Standard packing Carton: 50 pcs. Case: 500 pcs.
2. 1 coil latching also available as option. Contact our sales office for details.
3. UL/CSA approved type is standard.
TYPES AND COIL DATA at 20
°
C 68
°
F
Single side stable
2 coil latching
Note: Insert 2, 3 or 4 in
for contact form reguired.
Type
Nominal
voltage,
V DC
Pick-up
voltage,
V DC (max.)
Drop-out
voltage,
V DC (min.)
Nominal
operating
current,
mA
Coil resistance,
(
±
10%)
Inductance,
mH
Nominal
operating
power,
mW
Maximum
allowable
voltage,
V DC (40
°
C)
S
EB-3V 3 2.1 0.3 66.7 45 23 200 5.5
S
EB-5V 5 3.5 0.5 38.5 130 65 192 9.0
S
EB-6V 6 4.2 0.6 33.3 180 93 200 11.0
S
EB-12V 12 8.4 1.2 16.7 720 370 200 22.0
S
EB-24V 24 16.8 2.4 8.4 2,850 1,427 202 44.0
S
EB-48V 48 33.6 4.8 5.6 8,500 3,410 271 75.0
Type
Nominal voltage,
V DC
Set and reset
voltage,
V DC (max.)
Nominal operating
current,
mA
Coil resistance,
(
±
10%)
Inductance,
mH
Nominal
operating
power,
mW
Maximum
allowable
voltage,
V DC (40
°
C)Coil I Coil II Coil I Coil II
S
EB-L2-3V 3 2.1 66.7 45 45 10 10 200 5.5
S
EB-L2-5V 5 3.5 38.5 130 130 31 31 192 9.0
S
EB-L2-6V 6 4.2 33.7 180 180 40 40 200 11.0
S
EB-L2-12V 12 8.4 16.7 720 720 170 170 200 22.0
S
EB-L2-24V 24 16.8 8.4 2,850 2,850 680 680 202 44.0
S
EB-L2-48V 48 33.6 7.4 6,500 6,500 1,250 1,250 355 65.0
DIMENSIONS
General tolerance:
±
0.3
±
.012
PC board pattern (Copper-side view)
Tolerance:
±
0.1
±
.003
10±0.5
.394±0.02
12
.472
7.62
.300
123456
12 11 10 9 8 7
3
.118
1
.039
4
.157
0.4
.016
1.4
.055
1.0
.039
5.08
.200
0.5
.020
0.5
.020
7.62
.300
28±0.5
1.102±0.02
12
.472
2.54
.100
2.54
.100
12-1.3 DIA.
.047-.051 DIA.
mm inch
Schematic
(Bottom view)
Single side stable
Deenergized position
2a2b 3a1b 4a
123456
12 11 10 9 8 7
-
+
123456
12 11 10 9 8 7
-
+
123456
12 11 10 9 8 7
-
+
2 coil latching
Diagram shows the "reset"
position when terminals 6
and 7 are energized.
Energize terminals 1 and
12 to transfer contacts.
2a2b 3a1b 4a
123456
12 11 10 9 8 7
Set Reset
-
+
-
+
-
Set Reset
+
123456
12 11 10 9 8 7
-
+
-
Set Reset
+
123456
12 11 10 9 8 7
-
+
ORDERING INFORMATION
S
221
REFERENCE DATA
1. Maximum switching power 2. Life curve 3. Contact reliability
Condition: 1V DC, 1mA
Detection level 10
Tasted Sample: S4EB-24V, 10pcs
100
1,000
10
0.1 1 10
Contact current, A
Contact voltage, V
DC resistive load
AC resistive load
1,000
500
100
50
30
10
012345
Contact current, A
Life, ×10
4
125 V AC
(cosϕ = 1.0)
250 V AC
(cosϕ = 1.0)
99.9
99.0
95.0
0.1
1.0 10.0
0.2
0.5
1.0
2.0
5.0
10.0
30.0
50.0
70.0
No. of operations, ×10
7
m = 1.6
µ: 79 million time
σ: 51 million time
95% reliability limit:
14.6 million times
(weibul probability paper)
4.-(1) Coil temperature rise
Tested Sample: S4EB-24V, 4 Form A
4.-(2) Coil temperature rise
Tested Sample: S4EB-24V, 4 Form A
5.-(1) Operate and release time
(Single side stable type)
Tested Sample: S4EB-24V, 10pcs
4A
0A
100
0.2 0.4 0.6 0.8 1.0 1.2
90
80
70
60
50
40
30
20
10
0
Coil operating power, W
Temperature rise, °C
100
123456
90
80
70
60
50
40
30
20
10
0
Coil operating
power, 0.2 W
Contact current, A
Temperature rise, °C
Min.
Max.
Min.
Max.
Min.
Max.
80 100 120 140
20
18
16
14
12
10
8
6
4
2
0
Coil applied voltage, %V
Operate/release time, ms
Release time (with diode)
Operate time
Release time
5.-(2) Operate time (2 coil latching type)
Tested Sample: S2EB-L2-12V
Min.
Min.
Max.
Max.
20
80 100 120 140
18
16
14
12
10
8
6
4
2
Coil applied voltage, %V
Operate/release time, ms
(with diode)
(without diode)
6. Influence of adjacent mounting
510
–30
0
+30
510
–30
0
+30
(1) (2) (3)
(1) & (3) relays
are energized
Rate of change, %
Rate of change, %
Single side stable 2 coil latching
Drop-out voltage
Pick-up voltage
Pick-up voltage
Inter-relay distance, mm Inter-relay distance, mm
Note: When installing an S-relay near another, and there is no effect
from an external magnetic field, be sure to leave at least 10 mm
.394 inch between relays in order to acheive the performance
listed in the catalog.
7. Thermal electromotive force
200
2 4 6 8 10 12
100
Minute
NR-H
NF relay
S relay
Thermal electromotive force, µV
8. Effect from an external magnetic field
0
0
50 100
–30
+30
50 100
–30
+30
Rate of change, %Rate of change, %
G
G
Pick-up voltage
Pick-up voltage
Drop-out voltage
Single side stable
2 coil latching
φ
50 100
–30
–30
0
+30
50 100
0
+30
Rate of change, %Rate of change, %
G
G
Pick-up voltage
Pick-up voltage
Drop-out voltage
Single side stable
2 coil latching
φ
12NEXT