Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

782XBXM4L-24D

Part # 782XBXM4L-24D
Description
Category RELAY
Availability Out of Stock
Qty 0
Qty Price
1 + $9.30430
Manufacturer Available Qty
  • Out Of Stock



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
DIN ADAPTER
16-781C
FLANGE ADAPTER
16-781C1
700 SERIES ICE CUBE POWER RELAYS
781
SPDT
15 AMPS
782
SPDT
20 AMPS
DPDT
15 AMPS
783
3PDT
15 AMPS
784
4PDT
15 AMPS
FLANGE ADAPTER
16-782C1
DIN ADAPTER
16-782C
FLANGE ADAPTER
16-783C1
DIN ADAPTER
16-783C
FLANGE ADAPTER
16-784C1
DIN ADAPTER
16-784C
UL Recognized
File No. E43641
C US
40787
FEATURES
BENEFITS
FLAG INDICATOR:
BI - POLAR L.E.D.
STATUS LAMP:
COLOR CODED
PUSH BUTTON:
LOCK-DOWN DOOR:
FINGER - GRIP COVER:
WHITE PLASTIC
I.D. TAG/WRITE LABEL:
COVER ADAPTERS:
SHOWS RELAY STATUS IN MANUAL OR
POWERED CONDITION.
ALLOWS FOR REVERSE POLARITY APPLICATIONS,
SHOWS COIL "ON" OR "OFF" STATUS.
IDEAL IN LOW LIGHT CONDITIONS.
IDENTIFIES AC COILS WITH RED OR DC COILS WITH BLUE
PUSH BUTTONS. ALLOWS FOR MANUAL OPERATION OF
RELAY WITHOUT THE NEED FOR COIL POWER. IDEAL FOR
FIELD SERVICE PERSONNEL TO TEST CONTROL CIRCUITS.
WHEN ACTIVATED, HOLDS PUSH BUTTON
AND CONTACTS IN THE OPERATE POSITION.
EXCELLENT FOR ANALYZING CIRCUIT PROBLEMS.
ALLOWS OPERATOR TO REMOVE RELAYS FROM
SOCKETS MORE EASILY THAN
CONVENTIONAL RELAYS.
USED FOR IDENTIFICATION OF RELAYS
IN MULTI-RELAY CIRCUITS.
DIN RAIL ADAPTER OR TOP/BOTTOM FLANGE
ADAPTER, ALLOWS THE 700 RELAYS TO
BE DIRECT MOUNTED TO A DIN RAIL OR PANEL.
MANUFACTURED
UNDER
ISO 9002
& QS 9000
COMPLIES WITH REQUIREMENTS OF
IEC STANDARDS 947-4-1 AND
947-5-1 LOW VOLTAGE DIRECTIVE
IEC = INTERNATIONAL
ELECTROTECHNICAL COMMISSION
CE TESTING AND EVALUATION
PERFORMED BY THE UNDERWRITERS
LABORATORIES AS A THIRD PARTY
PARTICIPANT
*
*
*
LISTED 367G
IND. CONT. EQ.
C US
WHEN USED WITH
SOCKETS:
781:70-781D-1
782:70-782D-1
70-459-1
70-461-1
783:70-783D-1
784:70-784D-1
CURRENT LIMITED
TO RATING OF
RELAY OR SOCKET
WHICHEVER IS LESS
OPTIONAL ADAPTERS ORDERED SEPARATELY
1...12
9/04
1...13
9/04
GENER
GENER
AL SPECIFIC
AL SPECIFIC
A
A
TIONS (@
TIONS (@
25
25
ºC
ºC
)
)
85
80
10
10
110
15
0.9
0.7
Class B (130 ºC)
2.55
2.3
Continuous
Silver alloy,
gold flashed
15
277
15 / 0.5
28 / 220
10 @ 240
1/2 @ 120 V
1 @ 250 V
B300
AC15
3600
360
100 @ 5 VDC
or 0.5 W
20
20
2500
1500
100 @ 500
10-55 Hz, 6 gs,1mm
double amplitude
10
-40
+70
-40
+70
-40
+105
15 A: 100,000
20 A: 50,000
10,000,000
Any
Molded plastic
Polycarbonate
40
0.187, 0.1, 0.08 x 0.020
(4.47, 2.54, 2.03 x 0.508)
29
COIL
COIL
Pull-in Voltage AC (50/60 Hz):<
Pull-in Voltage DC:
<
Dropout Voltage AC (50/60 Hz):>
Dropout Voltage DC:>
Maximum Voltage:
Resistance:
Coil Power AC (60 Hz):
Coil Power DC:
Insulation System Per UL Standard 1446:
Maximum Coil Dissipation, AC (60 Hz):
Maximum Coil Dissipation, DC:
Duty:
CONT
CONT
A
A
CTS
CTS
Contact Material:
Contact Rating AC Amperes (AC1):
Contact Rating AC Voltage:
Contact Rating DC Amperes (DC1):
Contact Rating DC Voltage:
General Purpose Rating (75%-80% pf):
Horse Power (AC):
Horse Power (AC):
Pilot Duty (60 Hz):
Utilization Category:
VA Rating Make:
VA Rating Break:
Minimum Recommended Load:
TIMING
Operate Time:
Release Time:
DIELECTRIC S
DIELECTRIC S
TRENGTH
TRENGTH
Coil to Contacts:
Across Open Contacts:
Pole to Pole:
Insulation Resistance:
VIBR
VIBR
A
A
TION RESIS
TION RESIS
T
T
ANCE
ANCE
Functional:
SHOCK RESIS
SHOCK RESIS
T
T
ANCE
ANCE
Functional:
TEMPER
TEMPER
A
A
TURE
TURE
Operating, AC Lower:
Operating, AC Upper:
Operating, DC Lower:
Operating, DC Upper:
Storage, Lower:
Storage, Upper:
LIFE EXPECT
LIFE EXPECT
ANC
ANC
Y
Y
Electrical @ Rated Load (AC1):
Mechanical @ no Load :
MISCELLANEOUS
Operating Position:
Insulation Material:
Enclosure Material:
Cover Protection Category:
Terminals:
Weight:
UNITS
UNITS
% of nominal
% of nominal
% of nominal
% of nominal
% of nominal
% ±
VA
W
VA
W
A
V
A
V
A @ V
HP
HP
IEC
VA
VA
ma
ms
ms
V rms
V rms
V rms
megohms
minimum @ VDC
gs
gs
ºC
ºC
ºC
ºC
ºC
ºC
operations
operations
94V-0
94V-0
IP
Inch (mm)
grams
781XAX
781XAX
782XAX
782XAX
783
783
784
784
782XBX
782XBX
85
80
10
10
110
15
1. 2
0.9
Class B (130 ºC)
2.55
2.3
Continuous
Silver alloy,
gold flashed
20
277
20 / 0.5
28 / 220
1/2 @ 120 V
1 @ 250 V
B300
AC15
3600
360
100 @ 5 VDC
or 0.5 W
20
20
2500
1500
100 @ 500
10-55 Hz, 6gs 1mm
double amplitude
10
-40
+70
-40
+70
-40
+105
100,000
10,000,000
Any
Molded plastic
Polycarbonate
40
0.187, 0.08 x 0.020
(4.47, 2.03 x 0.508)
36
85
80
10
10
110
15
1. 2
0.9
Class B (130 ºC)
2.55
2.3
Continuous
Silver alloy,
gold flashed
15 / 12
120 / 277
12 / 0.5
28 / 220
1/2 @ 120 V
1 @ 250 V
B300
AC15
3600
360
100 @ 5 VDC
or 0.5 W
25
20
2500
1000
2500
100 @ 500
10-55 Hz, 6gs 1mm
double amplitude
10
-40
+70
-40
+70
-40
+105
200,000
10,000,000
Any
Molded plastic
Polycarbonate
40
0.187, 0.08 x 0.020
(4.47, 2.03 x 0.508)
36
85
80
10
10
110
15
1. 5
2
Class B (130 ºC)
3
2.3
Continuous
Silver alloy,
gold flashed
15 / 12
120 / 277
15 / 0.5
28 / 220
1/2 @ 120 V
3/4 @ 250 V
B300
AC15
3600
360
100 @ 5 VDC
or 0.5 W
20
20
2500
1000
2500
100 @ 500
10-55 Hz, 6gs1mm
double amplitude
10
-40
+70
-40
+70
-40
+105
150,000
10,000,000
Any
Molded plastic
Polycarbonate
40
0.187, 0.08 x 0.020
(4.47, 2.03 x 0.508)
80
85
80
10
10
110
15
1. 5
1. 7
Class B (130 ºC)
3
3.4
Continuous
Silver alloy,
gold flashed
15 / 12
120 / 277
15/ 0.5
28 / 220
1/2 @ 120 V
3/4 @ 250 V
B300
AC15
3600
360
100 @ 5 VDC
or 0.5 W
25
20
2500
1000
2500
100 @ 500
10-55 Hz, 6gs 1mm
double amplitude
10
-40
+70
-40
+70
-40
+105
150,000
10,000,000
Any
Molded plastic
Polycarbonate
40
0.187, 0.08 x 0.020
(4.47, 2.03 x 0.508)
60
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
700 SERIES ICE CUBE POWER RELAYS
OUTLINE DIMENSIONS
DIMENSIONS SHOWN IN INCHES & (MILLIMETERS).
782/78 - 2 POLE ICE CUBE POWER RELAYS
782XBXM4L-24A
782XBXM4L-120A
782XBXM4L-220/230A
782XBXM4L-240A
782XBXM4L-12D
782XBXM4L-24D
782XBXM4L-110D
9.6 W
180 W
4,430 W
15,000 W
15,700 W
40 W
160 W
650 W
2600 W
11,000 W
180 W
4,430 W
40 W
160 W
650 W
NOMINAL
INPUT
VOLTAGE
NOMINAL
RESISTANCE
(OHMS)
NEW PART NUMBER SUPERCEDES
NOTE: CLASS 782C IS AN ENHANCED VERSION OF THE 78, IT HAS SUPERIOR RATINGS,
A FLAG INDICATOR, & DISPLAYS BOTH PART NUMBERS.
W78ARCSX-7
W78ARCSX-9
W78ARCSX-11
W78ARCSX-12
W78RCSX-6
W78RCSX-7
W78RCSX-8
W78RCSX-9
W78RCSX-10
W78ARPCX-3
W78ARPCX-6
W78RPCX-1
W78RPCX-2
W78RPCX-3
782XBXC-6A
782XBXC-24A
782XBXC-120A
782XBXC-240A
782XBXC-6D
782XBXC-12D
782XBXC-24D
782XBXC-48D
782XBXC-110D
782XBXCT-24A
782XBXCT-120A
782XBXCT-6D
782XBXCT-12D
782XBXCT-24D
STANDARD PART NUMBERS
FULL
FEATURED
PLAIN COVER
WITH FLAG
SOLDER/PLUG -IN, 15 AMP
PRINTED CIRCUIT, 15 AMP
DPDT, 15 AMPS
WIRING DIAGRAM
(VIEWED FROM PIN END)
1
4
5
8
9
13
14
12
(42)
(44)
(41)
(A2)
(12)
(11)
(A1)
(14)
(14)
ALTERNATE NEMA
OR IEC ( ) NUMBERS
VIEWED FROM
PIN SIDE
COIL MEASURED @ 25ºC
QUICK CONNECT
SOLDER / PLUG-IN TERMINALS
Orange Flag
Indicator
1.54 MAX.
(39.1)
0.83 MAX.
(21.0)
1.10 MAX.
(27.9)
PRINTED CIRCUIT
TERMINALS
1.40 MAX.
(35.5)
Class 782
Plain Cover With Flag
Frosted Panel
Clear
Window
Push Button &
Lock-Down Door
Orange Flag
Indicator
Plastic
I.D Tag/Write Label
Green BI-Polar
L. E. D. Status Lamp
Standard
Cover
Standard
Cover
1
6
2
5
3
4
78
PRINTED CIRCUIT
MOUNTING HOLE
LAYOUT
( TOP VIEW )
0.39
(9.91)
0.28
(7.11)
0.52
(13.2)
0.70
(17.7)
0.56
(14.2)
0.10 (2.54) DIA.
8 Holes
Mating Sockets
70-782D-1, 70-459-1: SCREW/DIN
70-402-1: PRINTED CIRCUIT
70-401-1: SOLDER TERMINAL
See section 7
782 XBX
M4L -120A
CLASS:
CONTACT CONFIGURATION:
DPDT: XBX
OPTIONAL PLAIN COVER:
CODE C
TERMINAL STYLE:
QUICK CONNECT
SOLDER/
PLUG-IN TERMINALS: NO CODE
PRINTED CIRCUIT TERMINALS:
CODE T
FULL FEATURED VERSION:
PUSH BUTTON &
LOCK-DOWN DOOR: CODE M4
BI - POLAR L.E.D. STATUS LAMP: CODE L
OPTIONAL FULL FEATURED DELETION:
PUSH BUTTON WITHOUT
LOCK-DOWN DOOR: CODE M
OPTIONAL PLAIN COVER FEATURES:
PUSH BUTTON WITHOUT
LOCK-DOWN DOOR: CODE M
POLARIZED L.E.D. STATUS LAMP: CODE L
(OBSERVE POLARITY )
COIL VOLTAGE:
6, 12, 24, 120, 220/230, 240 ADD A FOR AC COILS
6, 12, 24 ,48, 110 ADD D FOR DC COILS
ORDERING CODE
ORDERING CODE
6 VAC, 50/60Hz
24 VAC, 50/60Hz
110/120 VAC, 50/60Hz
220/230 VAC, 50/60Hz
240 VAC, 50/60Hz
6 VDC
12 VDC
24 VDC
48 VDC
110/125 VDC
24 VAC, 50/60Hz
110/120 VAC, 50/60Hz
6 VDC
12 VDC
24 VDC
1.06
(26.9)
1...16
9/04
PHONE: (843) 393-5778 FAX: (843) 393-4123 EMAIL: info@magnecraft.com
DUAL MARKED
12NEXT