Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

SFP650-12BG

Part # SFP650-12BG
Description AC/DC Power Supply Single12V 53.3A 650W 30-Pin
Category POWER SUPPLY
Availability Out of Stock
Qty 0
Qty Price
1 + $238.11390



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

FEB 21, 2007 Page 1 of 9 www.power-one.com
SFP650-12BG AC-DC Front-End Data Sheet
12V Output, 650 Watts
Description
The SFP650-12BG is a 650-watt, power factor corrected (PFC) front-end which provides a 12 VDC output for
datacom and other distributed power applications. Its compact size enables mounting in both 1U and 2U height
racks. High efficiencies, advanced thermal management techniques, and an internal fan increase reliability over a
broad range of operating conditions. Internal ORing diodes facilitate use in hot-swap, redundant configurations.
Status is provided with front panel LEDs, logic signals, and via the I
2
C management interface bus. In addition, the
I
2
C bus can enable the power supply and control fan speed.
The SFP650-12BG meets international safety requirements and is CE marked to the Low Voltage Directive (LVD).
Model Selection
Model
Nominal
Output Voltage
(VDC)
Adjustment
Range (VDC)
Maximum
Output Current
(Amps)
Regulation
%
Ripple &
Noise @
20 MHz BW
(mV)
SFP650-12BG
12
3.3 (Standby)
N/A
N/A
53.3
3
±3
±3
100
100
Applications
Datacom
Distributed power systems
Features
Ideal server form factor optimizes, space,
efficiency, and load variations
High efficiency maximized between
30-80% load conditions
Unconditionally stable under any load
condition
NEBS level 3 compliance
(GR-63, -78, -1089)
Wide range DC-input model available
(SFD550-12BG)
Wide input voltage range (90-264 VAC)
with PFC
1U or 2U height configurations
Active current share with ORing FET
I
2
C interface status and control
Standby voltage of 3.3 VDC @ 3 A
Overtemperature, overload, and overvoltage
protection
Status LEDs: AC OK, DC OK, and
Overtemperature
FEB 21, 2007 Page 2 of 9 www.power-one.com
SFP650-12BG AC-DC Front-End Data Sheet
12V Output, 650 Watts
Input Specifications
Parameter Conditions/Description Min. Nom. Max. Units
AC Input Voltage Single-phase continuous input range. 90 264 VAC
Input Frequency AC input. 47 63 Hz
Hold-up Time After last AC line peak at full power.
At 115 VAC.
20
ms
Input Current At full-rated load. At 90 VAC. 6 A rms
Inrush Surge Current Excluding Xcap. Vin = 264 VAC. 25 ºC 15 A pk
Power Factor Per EN61000-3-2 > 0.95 W/VA
Output Specifications
Parameter Conditions/Description Min. Nom. Max. Units
Efficiency Full rated load at 220 VAC input. 89
%
Minimum Load Minimum loading required to maintain
regulation.
0 A
Output Power 650 W
Overshoot Output voltage overshoot at turn-on. < 5 %
Transient Response Maximum recovery time to within 1% of initial
set point due to a 25% load change, 1A/µs.
12V output:
Standby output:
Maximum deviation: 12V output:
Standby output:
5
5
3
3
ms
ms
%
%
Turn-On Delay
with PS_ON signal
Time required for initial output voltage
stabilization after application of AC input or
ON/OFF signal.
1500 ms
Output Regulation See Model Selection data on page 1.
FEB 21, 2007 Page 3 of 9 www.power-one.com
SFP650-12BG AC-DC Front-End Data Sheet
12V Output, 650 Watts
Interface Signals and Internal Protection
1
Parameter Conditions/Description Min. Nom. Max. Units
Overvoltage Protection Latch-style overvoltage protection. 15
4.3
V
Overcurrent Protection Current limit (Latching Mode). 12V output:
Standby output:
38.4
3.2
47.6
6
A
Short-Circuit
Protection
Latching Mode.
Overtemperature/
Fan Failure Warning
12V output will shut down in the event of an
overtemperature condition or blocked fan rotor.
OT setpoint is 62 ±3 ºC. Supply's fan and Vaux
are active. Power supply will recover when OT
condition is removed. Amber OT LED will turn
ON to indicate fault condition.
PS_KILL Output enable. Pulled low on conjunction with PS_ON being pulled low allows V1 to be activated.
+12V Current Share 0 to 8V signal used for active current sharing.
Write Protect For factory use only.
PS A0 I
2
C Address.
SDA I
2
C Data line (3.3V).
SCL I
2
C Clock line (3.3V).
Tach Two pulses per fan revolution.
AC_OK/H High signal indicates AC is within PSU limits.
Present/L 100 Ohm resistor internally connected to RTN allowing the PSU to be detected on insertion.
Alert/L Low signal indicates PSU fan is running below speed or an overtemperature limit was exceeded.
PWROK/H High signal indicates both outputs are within regulation limits.
1
Refer to product specification for internal pull up impedances and timing of these signals.
123NEXT