Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

AC Input, Single Output Model Selection -
180W WITH 300 LFM FORCED-AIR COOLING
MODEL
OUTPUT ADJUSTMENT MAXIMUM OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %p-p (NOTE 2) ACCURACY
MPU150-S259 12V 11.6V to 16V 15A (Note 3) 0.1% 1% 1% 11.97V to 12.03V
MPU150-S262 24V 22.8V to 29.2V 7.5A (Note 3) 0.1% 1% 1% 23.95V to 24.05V
MPU150-S261 48V 45V to 56V 3.75A (Note 3) 0.1% 1% 1% 47.9V to 48.1V
AC Input, Multiple Output Model Selection -
150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY
+3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V
MPU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V
+12V Fixed 2A 0.4% 3% 1% 11.76V to 12.24V
+5V 5.0V to 5.5V 17.5A 0.4% 1% 1% 4.98V to 5.02V
MPU150-3524 +12V 10.8V to 13.2V 4A 0.4% 3% 1% 11.94V to 12.06V
+24V Fixed 2A 0.4% 3% 1% 23.52V to 24.48V
+5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V
MPU150-4000
+12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V
+2.5V 2.25V to 3.0V 30A (Note 4) 0.8% 2% 2% 2.49V to 2.51V
MPU150-4230
+3.3V 3.15V to 3.8V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 4A (Note 5) 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A (Note 5) 0.4% 1% 1% 4.98V to 5.0V
+3.3V 3.15V to 3.80V 30A (Note 4) 0.6% 1.5% 1% 3.28V to 3.32V
MPU150-4350
+5V 5.0V to 5.5V 15A (Note 4) 0.4% 1% 1% 5.00V to 5.04V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
+5V 5.0V to 5.5V 30A (Note 4) 0.4% 1% 1% 4.98V to 5.02V
MPU150-4530
+3.3V 3.15V to 3.60V 15A (Note 4) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A (Note 5) 0.4% 7% 1% 11.94V to 12.06V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 4) Total current between V1 and V2 is 30A, maximum rating.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5) Total current between V3 and V4 is 5A, maximum rating.
3) Total power of 180 Watts.
MPU150/MDU150 Series Data Sheet
JUN 08, 2006 revised to JUL 14, 2006 Page 1 of 6 www.power-one.com
The innovative MPU products incorporate Power Factor Correction (PFC) with a low-profile package designed to meet
1U height constraints. The MPU150-4530 and MPU150-4350 provide high current +3.3V and +5V on a single platform
to support mixed-mode, high-speed digital circuitry. Power-One’s unique dual converter architecture combines high
reliability with exceptional regulation.
All multiple output models feature remote sense on outputs V1 and V2 to provide independent compensation of output
cable losses. Other standard features include independent current sharing on V1 and V2, thermal shutdown, and
remote inhibit. Airflow of 300 linear feet per minute (LFM) is required to deliver the full power density of 3.0 watts per
cubic inch.
The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.
Description
Features
RoHS lead free solder and lead solder exempted products
are available
Power Factor Correction (PFC) meets EN61000-3-2
Low-profile height fits 1U constraints
Dual main outputs provide 3.3V and 5V for mixed mode
applications
Single wire current sense on outputs V1 and V2
Remote sense on outputs V1 and V2
Overtemperature, overload, and overvoltage protection
Available with metric or SAE mountings
Greater than 340,000 Hours MTBF
MDU150 models have 48VDC input
Model numbers highlighted in yellow or shaded are not recommended for new designs. See MPU200 for new designs.
MPU150/MDU150 Series Data Sheet
JUN 08, 2006 revised to JUL 14, 2006 Page 2 of 6 www.power-one.com
Ordering Information:
OPTIONS SUFFIXES TO ADD TO PART NUMBER
Metric Mounting Add “M” as a suffix to the model number to order chassis with M4 x 0.7 mounting inserts. Metric mounting
inserts are standard for single-output models MPU150-S259, MPU150-S261, and MPU150-S262.
RoHS lead solder exemption No RoHS suffix character required.
RoHS compliant for all 6 substances Add “G” as the last character of the part number.
DC Input Model Selection -
150W WITH 300 LFM FORCED-AIR COOLING
ISOLATED V3 AND V4 CAN BE USED AS POSITIVE OR NEGATIVE OUTPUTS
MODEL
OUTPUT ADJUSTMENT OUTPUT LINE LOAD RIPPLE & NOISE INITIAL SETTING
VOLTAGE RANGE CURRENT (NOTE 1) REGULATION REGULATION %Pk-Pk (NOTE 2) ACCURACY
+3.3V 3.15V to 3.80V 35A 0.6% 1.5% 1.5% 3.28V to 3.32V
MDU150-3300 +5V 5.0V to 5.5V 20A 0.4% 3% 1% 4.98V to 5.02V
+12V N/A 2A 0.4% 3% 1% 11.76V to 12.24V
+5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V
MDU150-4000
+12V 10.8V to 13.2V 8A 0.4% 1% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A 0.4% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5V 2A 0.4% 1% 1% 4.98V to 5.02V
+2.5V 2.25V to 3.0V 30A (Note 3) 2% 2% 2% 2.49V to 2.51V
MDU150-4230
+3.3V 3.15V to 3.8V 15A (Note 3) 1.5% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 3A 1% 1% 1% 11.94V to 12.06V
5V 5.0V to 5.5 V 2A 1% 1% 1% 4.98V to 5.0V
+3.3V 3.15V to 3.8V 30A (Note 5) 1.5% 1.5% 1% 3.28V to 3.32V
MDU150-4350
+5V 5.0V to 5.5V 15A (Note 5) 1% 1% 1% 5.00V to 5.04V
12V 10.8V to 13.2V 3A (Note 4) 7% 7% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A (Note 4) 7% 7% 1% 11.94V to 12.06V
+5V 5.0V to 5.5V 30A (Note 3) 0.4% 1% 1% 4.98V to 5.02V
MDU150-4530
+3.3V 3.15V to 3.60V 15A (Note 3) 0.6% 1.5% 1.5% 3.28V to 3.32V
12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V
12V 10.8V to 13.2V 3A (Note 4) 0.4% 7% 1% 11.94V to 12.06V
NOTES: 1) Output currents ratings are expressed with 300 LFM forced air. 4) Total current between V3 and V4 is 5A, maximum rating.
2) Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. 5) Total current between V1 and V2 is 40A, maximum rating.
3) Total current between V1 and V2 is 30A, maximum rating.
MPU150 Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Continuous input range. 85 264 VAC
Input Frequency AC input. 47 63 Hz
Hold-up Time After last AC line peak at 150 watts. MPU150-4350 17.5 ms
All other models 20
Input Current 85 VAC at full rated load. MPU150 3.0 ARMS
Input Protection Non-user serviceable internally located AC input line fuse.
Inrush Surge Current Internally limited by thermistor. Vin = 230 VAC, one cycle, 25°C. 35 APK
Power Factor Per EN61000-3-2. 0.95 W/VA
Operating Frequency Switching frequency of main output transformer. 100 120
Switching frequency of secondary transformer. 65 90 kHz
Switching frequency of Power Factor Correction circuit. 60
MDU150 Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - DC Continuous input range. 36 75 VDC
Brown Out Protection Lowest DC input voltage that regulation is maintained with full rated loads. 34 VDC
Hold-up Time At 150 watts, over DC input range. 20 ms
Input Current 36 VDC at full rated load. 6.4 ARMS
Input Protection Non-user serviceable internally located AC input line fuse.
Operating Frequency Switching frequency of main output transformer. 100
kHz
Switching frequency of secondary transformer. 70
Inrush Current Consult factory.
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Efficiency Full Rated Load, 110 VAC. Varies with distribution of loads among outputs. 65 75 %
Minimum Load, V1 Minimum load required to maintain regulation on, Triple output models V1 4
A
V2 at maximum load. Quad output models V1 3
Minimum load required on single output models. Single output models V1 0
Minimum Load, V3 Minimum load required to maintain regulation on Quad output models V3 0.3
A
V4 at maximum load. Triple output models V3 0
Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts
Output Power With 300 LFM forced air cooling. (Note 1) 150 Watts
Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 3 5 %
Regulation Varies by output. Total regulation includes: line changes over the specified.
See Model Selection Charts
input range, changes in load starting at 20% load and changing to 100% load.
Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change,
500 µs
5% max. deviation.
Turn-on Delay Time required for initial output voltage stabilization. 2 s
Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 50 ms
NOTES: 1) This product is not rated for convection applications.
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection Latch style overvoltage protection. Available on 2.5V output, V1 3.0 3.25
V1, V2, all models, and V3 on all models except 3.3V output, V1 4.1 4.65
MPU150-3300. 3.3V output, V2 3.8 4.2
5V output, V1, V2 6.0 6.4
12V output, V2 14 16 V
12V output, V3 14 19
MPU150-4350G 3.3V output, V1 4.3 4.65
MPU150-S259 V1 17.0 20.5
MPU150-S262 V1 32.0 38.0
MPU150-S261 V1 58.0 62.7
Overload Protection Fully protected against output overload and short circuit. Automatic recovery upon removal of overload condition.
Overtemperature Protection System shutdown due to excessive internal temperature, automatic reset.
Output Good Signal, TTL compatible signal available for V1. Pull-up resistor is 10k. Signal 3.3V 3.16 3.25
Low to High Transition is high when output is above the specified limits. Signal shall remain low 5V 4.75 4.90
for 20 milliseconds following loss of Output Good. MPU150-S259 12V 10.5 11.9 V
MPU150-S262 24V 21.5 23.5
MPU150-S261 48V 43.0 47.0
Input Power Fail Warning TTL compatible logic signal. Time before regulation dropout due to loss of input
5ms
power. May be used as independent PSOK signal in redundant applications.
Current Share Accuracy of shared current with up to 6 parallel units. Single wire current share 10 %
on V1 and V2 with return via -Sense return.
Remote Sense Available on V1 and V2. Total voltage compensation for cable losses with
500 mV
respect to the main output.
Inhibit Output voltage is inhibited by application of an external high (5V) signal.
MPU150/MDU150 Series Data Sheet
JUN 08, 2006 revised to JUL 14, 2006 Page 3 of 6 www.power-one.com
12NEXT