Part # VCT60US15
Description AC/DC CONVERTER 15V 60W
Category MODULE
Availability Out of Stock
Qty 0
Qty Price
1 + $20.76218



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

AC-DC
Specification
60 Watts
Low Cost
Single Outputs from 5 V to 30 V
P
eak Load Capability
Convection-cooled
<0.5 W No Load Input Power
2”x 4”Package
Fits 1U Applications
VCT Series
Input
Input Voltage 85-264 VAC
Input Frequency 47-63 Hz
Input Current 1.7 A max at 115 VAC, 0.85 A max at
230 VAC
Inrush Current 80 A typ. at 230 VAC, cold start at 25 °C
Earth Leakage Current 500 µA at 264 VAC / 60 Hz
Power Factor EN61000-3-2, class A
No Load Input Power <0.5 W
Input Protection Internal T3.15A/250 V fuse in line
Output
Output Voltage See table
Output Voltage Trim None
Initial Set Accuracy ±2% at 50 % load
Minimum Load No minimum load requirement
Start Up Delay 2 s max
Start Up Rise Time 8 ms typical
Hold Up Time 8 ms typical at full load and 115 VAC
Line Regulation ±0.5% max
Load Regulation ±1.0% max (see note 1)
Transient Response 4% maximum deviation, recovering to less
than 1% within 500 µs for 50% step load
Ripple & Noise 1% max pk-pk (see note 2)
Overvoltage Protection See table
Overload Protection 133-166%
Short Circuit Protection Trip and restart (hiccup mode)
Temperature 0.02% / ˚C
Coefficient
xppower.com
General
Efficiency See table
Isolation 3000 VAC Input to Output
1500 VAC Input to Ground
500 VDC Output to Ground
Switching Frequency 60 kHz ±10 kHz
MTBF >700 kHrs to Bell Core iss. 6
Environmental
Operating Temperature -10 ˚C to +70 ˚C derate from 100% load
at 50 ˚C to 50% load at 70 ˚C
Cooling Natural convection
Operating Humidity 5% to 90% RH, non condensing
Operating Altitude 3000 m
Storage Temperature -20 ˚C to +85 ˚C
Shock IEC68-2-6, 30 g, 11 mins half sine, 3 times
in each of 6 axes
Vibration IEC68-2-27, 10-500Hz, 2 g 10 mins /
sweep. 60 mins for each of 3 axes
EMC & Safety
Emissions EN55022, level B conducted & radiated
Harmonic Currents EN61000-3-2 class A
Voltage Flicker EN61000-3-3
ESD Immunity EN61000-4-2, level 3, Perf Criteria A
Radiated Immunity EN61000-4-3, 10 V/m, Perf Criteria A
EFT/Burst EN61000-4-4, level 3, Perf Criteria A
Surge EN61000-4-5, installation class 3,
Perf Criteria A
Conducted Immunity EN61000-4-6, 10 V, Perf Criteria A
Dips & Interruptions EN61000-4-11, 30% 10 ms,
60%, 100 ms, 100%, 5000 ms
Perf Criteria A, B, B
Safety Approvals UL60950-1, IEC60950-1, EN60950-1
B R A N D
16-Aug-16
AC-DC
VCT60
Models and Ratings
Output Voltage
(6)
Output Current
OVP Setting
(5)
Efficiency
(4)
Model Number
Nominal Peak
(3)
5.0 V 8.00 A 10.0 A 7.0 V 82% VCT40US05
12.0 V 5.00 A 6.3 A 13.0 V 87% VCT60US12
15.0 V 4.00 A 5.0 A 17.0 V 87% VCT60US15
24.0 V 2.50 A 3.1 A 29.0 V 88% VCT60US24
Mechanical Details
1
. Load regulation is measured from 60% to full load and from 60% to 20% load (60% ±40% full load).
2. Measured at the output connector with a 0.1 µF ceramic capacitor and a 10 µF electrolytic capacitor.
3. Peak load lasting <30 s with a maximum duty cycle of 10%, average output power not to exceed nominal.
4
. Average of efficiencies measured at 25%, 50%, 75% & 100% load and 230 VAC input.
5. Typical trip point.
6. Other voltages between 5 V and 30 V available on request, contact sales for details.
1. All dimensions shown in inches (mm).
2. Weight 0.29 lbs (130 g) approx
3. Tolerance: x.xx = ±0.04 (x.x = ±0.1); x.xxx = ±0.2 (x.xx = ±0.5)
Notes
Notes
Ø0.13 (3.5)-4 Places
0.06 (1.6) PCB Thickness
0.09 (2.5) Lead Length
4.0 (101.6)
0.78
(20.0)
0.94
(24.1)
2.0
(50.8)
0.12 (3.2)
3.75 (95.3)
0.12
(3.1)
1.75
(44.5)
1
4
2
1
Input Connector
Pin 1 Neutral
Pin 2 Live
Output Connector
1 +Vout
2 +Vout
3 -Vout
4 -Vout
Mates with: Molex Housing
09-50-3031 and Molex Series
2878 crimp terminals.
Mounting holes marked with
must be connected to
safety earth
Mates with: Molex Housing
09-50-3041 and Molex Series
2878 crimp terminals.