961-800-526-2324 • www.us.tdk-lambda.com/lp/ Disclaimer: us.tdk-lambda.com/lp/legal.htm
MTW Series
Features
u 26mm height
u 3 year Warranty
u Peak Load capable
u Light weight
u Output 1 isolated from outputs 2 & 3
u No minimum load
15W to 60W Low Profi le Triple Output Power Supplies
MTW15-51212 MTW30-51212 MTW60-51212
Model MTW15-51515 MTW30-51515 MTW60-51515
Input Voltage Range V 85 - 265VAC (47 - 440Hz)
Input Current Typ (1) A 0.42 / 0.25 0.8 / 0.4 1.4 / 0.8
Inrush Current (1) A 25 / 50 20 / 40 20 / 40
Leakage Current (240VAC, 60Hz) mA 0.75mA Max
Max Output Power W 16 30 60
17.5 33 62.5
Effi ciency (Typ) % 71 76 76
Hold Up Time (1) ms 20 / 150 20 / 140 10 / 20
Output Voltage Adjustment (3) - V1: 5 to 5.25V V1: 5 to 5.2V V1: 4.5 to 5.5V
Overcurrent Protection - Yes, automatic recovery. Hiccup style on MTW30 & 60
Overvoltage Protection V V1: Zener Clamp V1: Zener Clamp V1 & V2: Zener Clamp
Operating Temperature - -20°C start up. -10 to +60°C, derating linearily to 70% load above 50°C
Storage Temperature - -30 to +75°C
Humidity (Non condensing) - 10 - 90%RH (Operating & storage) at 35°C
Cooling - Convection
Withstand Voltage - Input to ground 2kVAC, Input to output 3kVAC, Output to ground 500VAC
Vibration (non operating) - 5 - 10Hz: 10mm amplitude, 10 - 200Hz: 2G (19.6m/s
2
)10m sweep time, 3 axis, 1 hour each
Shock - Acceleration: 60G (588m/s
2
) Half sine wave, 6 - 16ms pulse duration, 3x each direction
Safety Agency Approvals - UL60950-1, CSA C22.2 No 60950-1 (C-UL), EN60950-1
Immunity - EN61000-4-2 (Lv 4), -3, -4 (Lv 3), -5 (Lv 4), -6 (Lv 3), -8 (Lv 4), -11
Conducted EMI - FCC-Class B, EN55011-B, EN55022-B
Weight (Typ) g 150 210 330
Size (WxHxL) mm 50 x 26 x 127 65 x 26 x 140 83 x 26 x 185
Warranty yrs Three Years
Specifi cations
Notes:
(1) 100/240VAC
(2) Output V1 is isolated from outputs V2 & V3
(3) Option /V suffi x
Key Market Segments & Applications