North America: 1-800-272-5273 Europe: 32-11-300868 Asia: 886-2-2523-6368 Japan: 03-3980-2212
CYBERGATE
™
356
Note: For Mechanical Dimensions See Pages 408-415
DESCRIPTION
Clare’s CYG21XX Series DAA modules provide a
complete telephone line interface circuit in a small
1.07" x 1.07" x 0.4" package. The modules provide a
fast and cost effective solution for designs that
require an interface to the telephone line. The
CYG2100 is designed to meet PTT and safety
regulations in 13 countries.
The CYG2110 and CYG2120 are designed to meet PTT
regulations in France and Spain, respectively.
■
Low distortion transformer signal coupling
(0.01% max)
■
Complete ring detector circuit
■
Low power hookswitch
■
Electronic inductor/gyrator circuit
■
Surge protection
■
V.32 bis /V.34 compatible
■
PTT and safety regulations in 15 countries
■
PC board mountable
■
FCC Compatible
■
UL recognized file #: E174201
■
BSI certified:
■
BS EN 60950: 1992 Certificate # 8123
■
BABT recognized; listing pending
■
Home medical devices
■
Plant monitoring equipment
■
Security/alarm systems
■
Utility meters
■
Modems
■
Voicemail systems
■
Vending machines
■
Elevator control boxes
■
Network routers
■
PBX Systems
■
PC mother boards
■
Telephony applications
■
Digital telephone answering machines
CYG2100/CYG2110/CYG2120
APPLICATIONSFEATURES
APPROVALS
Parameter Min Typ Max Units
Isolation Voltage - - 1500 V
RMS
Operational Temperature 0 - 70
°
C
Storage Temperature 0 - 100
°
C
Relative Humidity 10 - 85 %
(Non-Condensing)
Soldering Temperature - - 260
°
C
Tip/Ring Load Current
(continuous) - - 120 mA
Hookswitch LED Drive Current - - 50 mA
Hookswitch LED Reverse Voltage - - 5 V
Ring Detect Phototransistor
Voltage V
CC
--20V
RATINGS (@ 25˚ C)