Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

5EFM4S

Part # 5EFM4S
Description
Category MODULE
Availability Out of Stock
Qty 0
Qty Price
1 + $15.11980



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

124
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics
Specifications subject
Germany: 49-89-6089-0
are metric equivalents. to change.
M Series
M Series
CORCOM Product Guide
The M series power entry modules offer the most choices
of power entry components and filtering options to fit a
specific need. The fully configured M series expands the
options of a manufacturer whose products are marketed
worldwide. One component, fully assembled and tested,
provides the capability of interfacing a multi-voltage power
supply to any common voltage or fusing scheme in the
world, without modification.
The IEC connector provides an internationally accepted
power entry termination, which can be used with a variety
of line cords.
The selectable fuseholder allows use of single or dual
European fuses, or a single North American fuse.
The optional DPST on/off switch breaks both sides of the
line and is labeled with the international I/O markings.
The optional voltage selector provides a convenient
means to change transformer primary connection,
and it is available in both 2-voltage and 4-voltage
configurations.
The series is available with four filter circuits to meet a
variety of applications, and convenient connections are
provided on unfiltered models to allow wiring of a
separate RFI filter.
The M series is a family of components offering greater
flexibility and cost-effectiveness in the selection of primary
power components. Wiring to the modules is accom-
plished via .110” terminals for labor savings and
convenience.
Four filter circuits provide a choice of attenuation tailored to
specific categories of susceptibility and emissions needs.
HM Models – This medical filter provides susceptibility
protection without the leakage current associated with
line-to-ground capacitors. Designed to allow equipment
to meet UL544 for patient care and non-patient care
equipment, the HM filter has a maximum leakage current
of 2 µA at 120 VAC 60 Hz. See Appendix C for more
information on medical applications and UL
standards.
FM Models – General purpose RFI filter designed for sus-
ceptibility applications, effectively providing RFI control of
line-to-ground noise. The design is compact and meets
the very low leakage current requirements of VDE portable
equipment as well as (120 Volt) UL544 non-patient medical
equipment.
XM Models – High performance RFI filter designed to bring
most digital equipment (including switching power
supplies) into compliance with FCC Part 15J, Class B
conducted emissions limits.
ZM Models – Premium RFI filter designed to bring most
digital equipment (including switching power supplies) into
compliance with EN55022, Level B (as well as FCC Part
15J, Class B) conducted emissions limits.
XM/ZM
V
M
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications
UL Recognized
CSA Certified
VDE Approved
Fuse Installation Instructions
1. Remove power cord.
2. Pry door open at socket.
3. Lift and swing door into socket.
4. Lift fuse holder out of housing.
5. Install one (1) AG fuse or two (2) metric fuses*.
6.
Replace fuse
holder into housing.
7.
Swing and snap door back in place.
*Install fuses on one side only, do not install both AG and metric fuses at the
same time.
125
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics
Specifications subject
Germany: 49-89-6089-0
are metric equivalents. to change.
Power Entry Modules
CORCOM Product Guide
M Series
Fuse Options
European Fusing Arrangement**
North American Fusing Arrangement**
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
**Install fuses on one side only. Do Not install both AG and Metric fuses at
the same time.
Voltage Selection
To change selected voltage: open cover, using small
blade screwdriver or similar tool; set aside cover/fuse
block assembly; pull voltage selector card straight out of
housing, using indicator pin; orient selector card so that
desired voltage is readable at the bottom; orient indicator
pin to point up when desired voltage is readable at bottom
(note that when indicator pin is fixed, successive voltages
are selected by rotating the card 90° clockwise); insert
voltage selector card into housing,
printed side of card
facing forward toward IEC connector and edge containing
the desired voltage first;
replace cover, and verify that
indicator pin shows the desired voltage.
Voltage Selector Card Orientation
00
00
22
22
22
11
11
44
33
00
00
00
00
44
22
22
11
33
00
00
00
00
22
22
11
11
44
33
00
00
00
00
22
22
22
11
44
33
100V
120V
230V 240V
00
22
00
00
11
Removing the Fuse Holder
A
A
S
ection A-A
"X"
Lift Up
1. Insert a pocket screwdriver at point “X” as shown.
Gently lift UP until the entire door lifts up approximately
1/4" (minimum).
2. Once lifted, the door will pivot on it’s hinges and
expose the fuse holder.
3. When the fuse holder is installed in the single fuse
position, apply the screwdriver as shown and gently
pry up. Use screwdriver as shown, do not use fingers.
When the fuse holder is installed in the dual fuse
position, it will normally release as soon as the
door is opened.
126
Catalog 1654001 Dimensions are in inches and Dimensions are shown for USA Cust. Svc.: 1-800-468-2023 www.corcom.com
Revised 05-07 millimeters unless otherwise reference purposes only. CORCOM Prods: 1-847-680-7400 www.tycoelectronics.com
specified. Values in italics
Specifications subject
Germany: 49-89-6089-0
are metric equivalents. to change.
CORCOM Product Guide
M Series
Power Entry Module with Optional RFI Power Line Filters for General and
Medical Applications (Continued)
Electrical Schematics – Unfiltered Models
VM (1-Voltage)
K
L
GG
Neutral
Hot
P
ower On/Off
Note 3
N
ote 2
C
ustomer
T
ransformer Primaries
L
K
1
20V
VM (2-Voltage)
B
D
E
F
A
C
D
E
F
HB
J
G
N
eutral
Hot
P
ower On/Off
Note 3
Note 2
Note 1
Note 1
Note 4
1
20V
240V
Customer
Transformer Primaries
LL
KK
C
F
A
120V
120V
120V
120V
VM (4-Voltage)
A
C
D
E
F
A
C
D
E
F
H
B
J
G
Neutral
Hot
Power On/Off
Note 3
Note 2
Note 1
Note 1
120V
100V
230V
240V
Customer
Transformer Primaries
L
K
20V
100V
120V
Note 1: Jumpers required if no input filter is used.
Note 2: Provision for dual European style fusing.
Note 3: On/off switch present only with "S" suffix.
Note 4: When using a center-tapped transformer, the C-F winding should
be the low voltage (high current) winding and must be capable of
handling the full primary current in the 120V position.
Specifications
M
aximum leakage current,each line-to-ground
HM
FM XM/ZM
@
120 VAC 60 Hz: 2
µA
.25 mA .30 mA
@ 250 VAC 50 Hz: 5
µA .50 mA .50 mA
Hipot rating (one minute):
l
ine-to-ground: 1500 VAC
line-to-line 1450 VDC
line-to-load (switch off) Unfiltered only 2500 VAC
Operating frequency: 50/60 Hz
Rated voltage (max.): 250 VAC
Operating voltages: 100, 120, 220/ 240 VAC
Switch: Double-insulated, rated for
100,000 operations at full load
at 70 Amps inrush current.
Fuse (not included): Reversible fuseholder, accepts
one 1/4" x 1-1/4" fuse
or two 5 x 20 mm fuses
Terminals: .110 [2.79] terminals
Minimum insertion loss in dB:
Line-to-ground in 50 ohm circuit
Current Frequency-MHz
Rating .01 .05 .15 .5 1 5 10 30
HM
5A - - 14 18 19 22 22 17
FM
05A - - 14 21 26 40 45 40
XM
3A 2 13 23 40 46 44 44 44
ZM
3A 15 29 39 46 43 40 40 40
Line-to-line in 50 ohm circuit
Current
Frequency-MHz
Rating .02 .03 .05 .07 .15 .5 1 5 10 30
XM
0
3A -
- - 5 34 62 68 60 50 40
ZM
3A 5 13 28 37 55 75 75 62 54 44
123NEXT