HAMAMATSU PHOTONICS K.K., Solid State Division
1126-1 Ichino-cho, Higashi-ku, Hamamatsu City, 435-8558 Japan, Telephone: (81) 53-434-3311, Fax: (81) 53-434-5184, www.hamamatsu.com
U.S.A.: Hamamatsu Corporation: 360 Foothill Road, P.O.Box 6910, Bridgewater, N.J. 08807-0910, U.S.A., Telephone: (1) 908-231-0960, Fax: (1) 908-231-1218
Germany: Hamamatsu Photonics Deutschland GmbH: Arzbergerstr. 10, D-82211 Herrsching am Ammersee, Germany, Telephone: (49) 08152-3750, Fax: (49) 08152-2658
France: Hamamatsu Photonics France S.A.R.L.: 19, Rue du Saule Trapu, Parc du Moulin de Massy, 91882 Massy Cedex, France, Telephone: 33-(1) 69 53 71 00, Fax: 33-(1) 69 53 71 10
United Kingdom: Hamamatsu Photonics UK Limited: 2 Howard Court, 10 Tewin Road, Welwyn Garden City, Hertfordshire AL7 1BW, United Kingdom, Telephone: (44) 1707-294888, Fax: (44) 1707-325777
North Europe: Hamamatsu Photonics Norden AB: Smidesvägen 12, SE-171 41 Solna, Sweden, Telephone: (46) 8-509-031-00, Fax: (46) 8-509-031-01
Italy: Hamamatsu Photonics Italia S.R.L.: Strada della Moia, 1/E, 20020 Arese, (Milano), Italy, Telephone: (39) 02-935-81-733, Fax: (39) 02-935-81-741
Information furnished by HAMAMATSU is believed to be reliable. However, no responsibility is assumed for possible inaccuracies or omissions.
Specifications are subject to change without notice. No patent rights are granted to any of the circuits described herein. ©2006 Hamamatsu Photonics K.K.
Cat. No. KMPD1085E02
Sept. 2006 DN
CCD area image sensor
S8984, S8985-02
7
■
Pin connections
Pin No. Symbol Description Remark
1GND
Ground
2 Vcc
+5 V power supply
3SG
Summing gate Same timing as P2H
4 Trigger B
Trigger B output
5RG
Reset gate
6 NC
7
Should be opened
8 NC
9RD
Reset drain
10 NC
11 OD
Output transistor drain
12 NC
13 OUT
Sensor output
14 NC
15 GND
Ground
16 NC
17 P1V
CCD vertical register clock-1
18 Reserve
Should be opened
19
Reserve
Should be opened
20 P2H CCD horizontal register clock-2
21
NC
22 P1H CCD horizontal register clock-1
23
NC
24 GND Ground
25
NC
26 RD Reset drain
27
NC
28 OD Output transistor drain
29
NC
30 GND Ground
31
NC
32 OUT Sensor output
33
NC
34 P2V CCD vertical register clock-2
35
NC
36 TG Transfer gate Same timing as P2V
■ Precautions for use (Electrostatic countermeasures)
*Handle these sensors with bare hands or wearing cotton gloves. In addition, wear anti-static clothing or use a wrist band with
an earth ring, in order to prevent electrostatic damage due to electrical charges from friction.
*Avoid directly placing these sensors on a work-desk or work-bench that may carry an electrostatic charge.
*Provide ground lines or ground connection with the work-floor, work-desk and work-bench to allow static electricity to dis-
charge.
*Ground the tools used to handle these sensors, such as tweezers and soldering irons.
It is not always necessary to provide all the electrostatic measures stated above. Implement these measures according to
the amount of damage that occurs.