MC100EPT22
http://onsemi.com
3
Table 3. MAXIMUM RATINGS
Symbol Parameter Condition 1 Condition 2 Rating Unit
V
CC
Power Supply GND = 0 V 6 V
V
I
Input Voltage GND = 0 V V
I
v V
CC
6 to 0 V
I
out
Output Current Continuous
Surge
50
100
mA
mA
T
A
Operating Temperature Range −40 to +85 °C
T
stg
Storage Temperature Range −65 to +150 °C
q
JA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
SOIC−8
SOIC−8
190
130
°C/W
°C/W
q
JC
Thermal Resistance (Junction−to−Case) Standard Board SOIC−8 41 to 44 °C/W
q
JA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
TSSOP−8
TSSOP−8
185
140
°C/W
°C/W
q
JC
Thermal Resistance (Junction−to−Case) Standard Board TSSOP−8 41 to 44 °C/W
q
JA
Thermal Resistance (Junction−to−Ambient) 0 lfpm
500 lfpm
DFN8
DFN8
129
84
°C/W
°C/W
T
sol
Wave Solder Pb
Pb−Free
265
265
°C
Stresses exceeding Maximum Ratings may damage the device. Maximum Ratings are stress ratings only. Functional operation above the
Recommended Operating Conditions is not implied. Extended exposure to stresses above the Recommended Operating Conditions may affect
device reliability.
Table 4. TTL INPUT DC CHARACTERISTICS V
CC
= 3.3 V, GND = 0 V, T
A
= −40°C to 85°C
Symbol
Characteristic Condition Min Typ Max Unit
I
IH
Input HIGH Current V
IN
= 2.7 V 20
mA
I
IHH
Input HIGH Current MAX V
IN
= V
CC
100
mA
I
IL
Input LOW Current V
IN
= 0.5 V −0.6 mA
V
IK
Input Clamp Voltage I
IN
= −18 mA −1.0 V
V
IH
Input HIGH Voltage 2.0 V
V
IL
Input LOW Voltage 0.8 V
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
Table 5. PECL OUTPUT DC CHARACTERISTICS V
CC
= 3.3 V, GND = 0.0 V (Note 2)
Symbol
Characteristic
−40°C 25°C 85°C
Unit
Min Typ Max Min Typ Max Min Typ Max
I
CC
Power Supply Current 32 43 55 35 45 60 37 46 62 mA
V
OH
Output HIGH Voltage (Note 3) 2155 2280 2405 2155 2280 2405 2155 2280 2405 mV
V
OL
Output LOW Voltage (Note 3) 1355 1480 1605 1355 1480 1605 1355 1480 1605 mV
NOTE: Device will meet the specifications after thermal equilibrium has been established when mounted in a test socket or printed circuit
board with maintained transverse airflow greater than 500 lfpm. Electrical parameters are guaranteed only over the declared
operating temperature range. Functional operation of the device exceeding these conditions is not implied. Device specification limit
values are applied individually under normal operating conditions and not valid simultaneously.
2. Output parameters vary 1:1 with V
CC
.
3. All loading with 50 W to V
CC
− 2.0 V.