XC2C64A CoolRunner-II CPLD
16 www.xilinx.com DS311 (v2.3) November 19, 2008
Product Specification
Additional Information
Additional information is available for the following
CoolRunner-II CPLD topics at
www.xilinx.com/support/documentation/coolrunner-ii.htm:
• Device pinouts in the density specific data sheets
• Termination, power sequencing, voltage thresholds,
and slew rate data in the CPLD IO User Guide
• Reliability data in the Device Reliability Report
• Packaging thermal and electrical data in the Device
Package User Guide
Package drawings and dimensions are available at:
www.xilinx.com/support/documentation/package_specifications.htm
Revision History
The following table shows the revision history for this document.
Date Version Revision
5/15/04 1.0 Initial Xilinx release.
8/30/04 1.1 Pb-free documentation
10/01/04 1.2 Add Asynchronous Preset/Reset Pulse Width specification to AC Electrical Characteristics.
11/08/04 1.3 Product Release. No change to documentation.
11/29/04 1.4 Change to QFG package drawing (Figure 8). Pin 29 relabelled.
12/14/04 1.5 Changes to Figure 4, Typical I/O Output Curves; Changes to t
OUT25
and t
OUT33
, Internal
Timing Parameters, page 8.
01/18/05 1.6 Changes to I
CCSB
, f
TOGGLE
, t
PSU1
, t
PSU2
, t
PHD
, t
CW
, t
SLEW25
, and t
SLEW33
03/07/05 1.7 Format change to specifications I
IL
and I
IH
, page 3. Improvement to pin-to-pin logic delay,
page 1. Modifications to Table 1, IOSTANDARDs.
06/28/05 1.8 Move to Product Specification. Change to T
IN25
, T
OUT25
, T
IN33
, and T
OUT33
.
01/30/06 1.9 Modified footnote 1 from AC Specifications Table to remove incorrect equation.
03/20/06 2.0 Add Warranty Disclaimer. Add note to Pin Descriptions that
GCK, GSR, and GTS pins can also
be used for general purpose I/O.
02/15/07 2.1 Change to V
IH
specification for 2.5V and 1.8V LVCMOS. Change T
F
specification on -7
speed grade from 2.0 to 3.0 ns.
03/08/07 2.2 Fixed typo in note for V
IL
for LVCMOS18; removed note for V
IL
for LVCMOS33.
11/19/08 2.3 Added note to Pin Description tables to indicate the PC44 packages are obsolete. Removed
part numbers for devices in PC44 packages the Features section and from the ordering
information. See Product Discontinuation Notice