TLC556, TLC556Y
DUAL LinCMOS TIMERS
SLFS047B – FEBRUARY 1984 – REVISED SEPTEMBER 1997
6
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
electrical characteristics at specified free-air temperature, V
DD
= 5 V
TEST
TLC556C TLC556I TLC556M
CONDITIONS
A
MIN TYP MAX MIN TYP MAX MIN TYP MAX
Input threshold
25°C 2.8 3.3 3.8 2.8 3.3 3.8 2.8 3.3 3.8
IT
voltage
Full range 2.7 3.9 2.7 3.9 2.7 3.9
25°C 10 10 10
res
o
curren
MAX 75 150 5000
p
25°C 1.36 1.66 1.96 1.36 1.66 1.96 1.36 1.66 1.96
(trigger)
r
gger vo
age
Full range 1.26 2.06 1.26 2.06 1.26 2.06
25°C 10 10 10
(trigger)
r
gger curren
MAX 75 150 5000
p
25°C 0.4 1.1 1.5 0.4 1.1 1.5 0.4 1.1 1.5
(reset)
ese
vo
age
Full range 0.3 1.8 0.3 1.8 0.3 1.8
25°C 10 10 10
(reset)
ese
curren
MAX 75 150 5000
p
Control voltage (open
circuit) as a
percentage of supply
voltage
MAX 66.7% 66.7% 66.7%
Discharge switch
25°C 0.15 0.5 0.15 0.5 0.15 0.5
on-state voltage
OL
=
m
Full range 0.6 0.6 0.6
Discharge switch
25°C 0.1 0.1 0.1
off-state current
MAX 0.5 2 120
n
High-level output
25°C 4.1 4.8 4.1 4.8 4.1 4.8
OH
voltage
OH
= –
m
Full range 4.1 4.1 4.1
25°C 0.21 0.4 0.21 0.4 0.21 0.4
OL
=
m
Full range 0.5 0.5 0.6
Low-level output
25°C 0.13 0.3 0.13 0.3 0.13 0.3
OL
voltage
OL
=
m
Full range 0.4 0.4 0.45
25°C 0.08 0.3 0.08 0.3 0.08 0.3
OL
=
.
m
Full range 0.35 0.35 0.4
pp
25°C 340 700 340 700 340 700
DD
Full range 1000 1200 1400
†
Full range is 0
°C to 70°C for TLC556C, –40°C to 85°C for TLC556I, and –55°C to 125°C for TLC556M.
NOTE 2: These values apply for the expected operating configurations in which THRES is connected directly to DISCH or to TRIG.