SLCS115E − DECEMBER 1986 − REVISED JULY 2003
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
POST OFFICE BOX 1443
• HOUSTON, TEXAS 77251−1443
recommended operating conditions
TLC393Q
MIN NOM MAX
UNIT
Supply voltage, V
DD
4 5 16 V
Common-mode input voltage, V
IC
0 V
DD
− 1.5 V
Low-level output current, I
OL
20 mA
Operating free-air temperature, T
A
−40 125 °C
electrical characteristics at specified operating free-air temperature, V
DD
= 5 V (unless otherwise
noted)
TLC393Q
PARAMETER
TEST CONDITIONS
†
T
A
MIN TYP MAX
UNIT
V
IC
= V
ICR
min,
25°C 1.4 5
V
IO
Input offset voltage
V
DD
= 5 V to 10 V,
See Note 4
−40°C to 125°C 10
mV
25°C 1 pA
I
IO
Input offset current V
IC
= 2.5 V
125°C 15 nA
25°C 5 pA
I
IB
Input bias current V
IC
= 2.5 V
125°C 30 nA
Common mode inp t oltage range
25°C 0 to V
DD
− 1
V
ICR
Common-mode input voltage range
−40°C to 125°C 0 to V
DD
− 1.5
V
25°C 84
CMMR Common-mode rejection ratio V
IC
= V
ICR
min
125°C 84
dB
−40°C 84
25°C 85
k
SVR
Supply-voltage rejection ratio V
DD
= 5 V to 10 V
125°C 84
dB
−40°C 84
25°C 300 400
V
OL
Low-level output voltage V
ID
= −1 V, I
OL
= 6 mA
125°C 800
mV
High le el o tp t c rrent
25°C 0.8 40 nA
I
OH
High-level output current V
ID
= 1 V, V
O
= 5 V
125°C 1 µA
pp
p
p
25°C 22 40
I
DD
Supply current (both comparators) Outputs low, No load
−40°C to 125°C 90
µA
†
All characteristics are measured with zero common-mode voltage unless otherwise noted.
NOTE 4: The offset voltage limits given are the maximum values required to drive the output up to 4.5 V or down to 0.3 V (with a 2.5-kΩ load to
V
DD
).