Absolute Maximum Ratings
(1)
Package Thermal Data
(1)
Recommended Operating Conditions
TL750L, TL751L SERIES
LOW-DROPOUT VOLTAGE REGULATORS
SLVS017S – SEPTEMBER 1987 – REVISED AUGUST 2005
over operating junction temperature range (unless otherwise noted)
MIN MAX UNIT
Continuous input voltage 26 V
Transient input voltage
(2)
T
A
= 25 ° C 60 V
Continuous reverse input voltage –15 V
Transient reverse input voltage t ≤ 100 ms –50 V
T
J
Operating virtual junction temperature 150 ° C
Lead temperature 1,6 mm (1/16 in) for 10 s 260 ° C
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) The transient input voltage rating applies to the waveform shown in Figure 1.
PACKAGE BOARD θ
JC
θ
JA
PDIP (P) High K, JESD 51-7 57 ° C/W 85 ° C/W
PowerFLEX™ (KTE) High K, JESD 51-5 3 ° C/W 23 ° C/W
SOIC (D) High K, JESD 51-7 39 ° C/W 97 ° C/W
TO-226/TO-92 (LP) High K, JESD 51-7 55 ° C/W 140 ° C/W
TO-220 (KC) High K, JESD 51-5 3 ° C/W 19 ° C/W
(1) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
over recommended operating junction temperature range (unless otherwise noted)
MIN MAX UNIT
TL75xL05 6 26
TL75xL08 9 26
V
I
Input voltage V
TL75xL10 11 26
TL75xL12 13 26
V
IH
High-level ENABLE input voltage TL75xLxx 2 15 V
T
J
= 25 ° C TL75xLxx –0.3 0.8
V
IL
(1)
Low-level ENABLE input voltage V
T
J
= 0 ° C to 125 ° C TL75xLxx –0.15 0.8
I
O
Output current TL75xLxx 0 150 mA
T
J
Operating virtual junction temperature TL75xLxxC 0 125 ° C
(1) The algebraic convention, in which the least positive (most negative) value is designated minimum, is used in this data sheet for
ENABLE voltage levels and temperature only.
3