Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

TL022CP

Part # TL022CP
Description DUAL LOW PWR OP AMPS/LINEAR -Rail/Tube
Category IC
Availability Out of Stock
Qty 0
Qty Price
1 + $0.32067



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

TL022C, TL022M
DUAL LOW-POWER OPERATIONAL AMPLIFIERS
SLOS076 – SEPTEMBER 1973 – REVISED SEPTEMBER 1990
1
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
Very Low Power Consumption
Power Dissipation With ±2-V Supplies
170 µW Typ
Low Input Bias and Offset Currents
Output Short-Circuit Protection
Low Input Offset Voltage
Internal Frequency Compensation
Latch-Up-Free Operation
Popular Dual Operational Amplifier Pinout
TL022M IS NOT RECOMMENDED FOR
NEW DESIGNS
description
The TL022 is a dual low-power operational
amplifier designed to replace higher power
devices in many applications without sacrificing
system performance. High input impedance, low
supply currents, and low equivalent input noise
voltage over a wide range of operating supply
voltages result in an extremely versatile
operational amplifier for use in a variety of analog
applications including battery-operated circuits.
Internal frequency compensation, absence of
latch-up, high slew rate, and output short-circuit
protection assure ease of use.
The TL022C is characterized for operation from 0°C to 70°C. The TL022M is characterized for operation over
the full military temperature range of –55°C to 125°C.
AVAILABLE OPTIONS
V
IO
max
PACKAGE
T
A
V
IO
max
AT 25
°
C
SMALL OUTLINE CERAMIC DIP PLASTIC DIP
CERAMIC FLAT PACK
AT
25 C
(D) (JG) (P)
CERAMIC
FLAT
PACK
(U)
0°C to 70°C 5 mV TL022CD TL022CP
–55°C to 125°C 5 mV TL022MJG TL022MU
The D package is available taped and reeled. Add the suffix R to the device type (i.e. TL022CDR).
Copyright 1990, Texas Instruments Incorporated
PRODUCTION DATA information is current as of publication date.
Products conform to specifications per the terms of Texas Instruments
standard warranty. Production processing does not necessarily include
testing of all parameters.
symbol (each amplifier)
1
2
3
4
8
7
6
5
1OUT
1IN
1IN+
GND
V
CC
2OUT
2IN
2IN+
TL022M ...JG PACKAGE
TL022C ...D OR P PACKAGE
(TOP VIEW)
1
2
3
4
5
10
9
8
7
6
NC
1OUT
1IN
1IN+
V
CC –
NC
V
CC+
2OUT
2IN
2IN+
TL022M ...U PACKAGE
(TOP VIEW)
+
IN+
OUT
IN
TL022C, TL022M
DUAL LOW-POWER OPERATIONAL AMPLIFIERS
SLOS076 – SEPTEMBER 1973 – REVISED SEPTEMBER 1990
2
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
schematic
Each Amplifier
Common to Both
Amplifiers
V
CC+
To Other
Amplifier
To Other Amplifier
V
CC
IN
IN+
OUT
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
TL022C TL022M UNIT
Supply voltage, V
CC+
(see Note 1) 18 22 V
Supply voltage, V
CC–
(see Note 1) –18 –22 V
Differential input voltage (see Note 2) ±30 ±30 V
Input voltage (any input, see Notes 1 and 3) ±15 ±15 V
Duration of output short circuit (see Note 4) unlimited unlimited
Continuous total dissipation See Dissipation Rating Table
Operating free-air temperature range 0 to 70 55 to 125 °C
Storage temperature range 65 to 150 65 to 150 °C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds JG or U package 300 °C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds D or P package 260 °C
NOTES: 1. All voltage values, unless otherwise noted, are with respect to the midpoint between V
CC+
and V
CC–
.
2. Differential voltages are at IN+ with respect to IN–.
3. The magnitude of the input voltage must never exceed the magnitude of the supply voltage or 15 V, whichever is less.
4. The output may be shorted to ground or either power supply. For the TL022M only, the unlimited duration of the short circuit applies
at (or below) 125°C case temperature or 75°C free-air temperature.
DISSIPATION RATING TABLE
PACKAGE
T
A
25°C
POWER RATING
DERATING
FACTOR
DERATE
ABOVE T
A
T
A
= 70°C
POWER RATING
T
A
= 125°C
POWER RATING
D 680 mW 5.8 mW/°C 33°C 464 mW
JG 680 mW 8.4 mW/°C69°C 672 mW 210 mW
P 680 mW 8.0 mW/°C65°C 640 mW
U 675 mW 5.4 mW/°C 25°C 432 mW 135 mW
TL022C, TL022M
DUAL LOW-POWER OPERATIONAL AMPLIFIERS
SLOS076 – SEPTEMBER 1973 – REVISED SEPTEMBER 1990
3
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
MIN MAX UNIT
Supply voltage, V
CC+
5 15 V
Supply voltage, V
CC
–5 –15 V
electrical characteristics at specified free-air temperature, V
CC±
= ±15 V (unless otherwise noted)
PARAMETER
TEST CONDITIONS
TL022C TL022M
UNIT
PARAMETER
TEST
CONDITIONS
MIN TYP MAX MIN TYP MAX
UNIT
V
IO
p
V
O
= 0,
25°C 1 5 1 5
mV
V
IO
u
v
O
,
R
S
= 50
Full range 7.5 6
mV
I
IO
p
V
O
=0
25°C 15 80 5 40
nA
I
IO
u
u
V
O
=
0
Full range 200 100
nA
I
IB
p
V
O
=0
25°C 100 250 50 100
nA
I
IB
u
u
V
O
=
0
Full range 400 250
nA
V
ICR
Common-mode input
25°C ±12 ±13 ±12 ±13
V
V
ICR
voltage range
Full range ±12 ±12
V
V
O(PP)
Maximum peak-to-peak
R
L
= 10 k 25°C 20 26 20 26
V
V
O(PP)
output voltage swing
R
L
10 k
Full range 20 20
V
A
VD
Large-signal differehtial R
L
10 kΩ,
25°C 60 80 72 86
dB
A
VD
voltage amplification
L
,
V
O
= ±10 V
Full range 60 66
dB
B
1
Unity-gain bandwidth 25°C 0.5 0.5 MHz
CMRR
Common-mode rejection V
IC
= V
ICR
min,
25°C 60 72 60 72
dB
CMRR
ratio
IC ICR
,
R
S
= 50
Full range 60 60
dB
k
SVS
Supply voltage sensitivity V
CC
= ± 9 V to ±15 V,
25°C 30 200 30 150
µV/V
k
SVS
(V
IO
/V
CC
)
CC
,
R
S
= 50
Full range 200 150
µ
V/V
A20dB
V
n
Equivalent input noise
A
VD
= 20 dB,
B=1Hz
f = 1 kHz
25°C
50 50 nV/Hz
B
=
1
Hz
,
I
OS
Short-circuit output current 25°C ± 6 ± 6 mA
I
CC
Supply current (both
V
O
=0
No load
25°C 130 250 130 250
µA
I
CC
amplifiers)
V
O
=
0
,
No
load
Full range 250 250
µ
A
P
D
Total dissipation
V
O
=0
No load
25°C 3.9 7.5 3.9 6
mW
P
D
(both amplifiers)
V
O
=
0
,
No
load
Full range 7.5 6
mW
All characteristics are measured under open-loop conditions with zero common-mode input voltage unless otherwise specified. Full range for
TL022C is 0°C to 70°C and for TL022M is –55°C to 125°C.
operating characteristics, V
CC±
= ±15 V, T
A
= 25°C
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
r
Rise time
V
I
=20mV
R
L
=10k
C
L
= 100
p
F
See Figure 1
0.3 µs
Overshoot factor
V
I
=
20
mV
,
R
L
=
10
k
,
C
L
=
100
pF
,
See
Fig
u
re
1
5%
SR Slew rate at unity gain V
I
= 10 V, R
L
= 10 kΩ, C
L
= 100 pF, See Figure 1 0.5 V/µs
12NEXT