Part # TE28F800C3BA90
Description NOR, Flash 512K x 16 48PinTSSOP
Category IC
Availability In Stock
Qty 375
Qty Price
1 - 78 $0.87249
79 - 157 $0.69403
158 - 236 $0.65437
237 - 315 $0.60810
316 + $0.54200
Manufacturer Available Qty
INTEL
Date Code: 0015
  • Shipping Freelance Stock: 190
    Ships Immediately
INTEL
Date Code: 0309
  • Shipping Freelance Stock: 16
    Ships Immediately
INTEL
Date Code: 0013
  • Shipping Freelance Stock: 167
    Ships Immediately
INTEL
Date Code: 0312
  • Shipping Freelance Stock: 2
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

Intel
£
Advanced+ Boot Block Flash Memory (C3)
28 Datasheet
5.1.1 Locking Operation
The locking status of each block can be set to Locked, Unlocked, or Lock-Down, each of which
will be described in the following sections. See Figure 5, “Block Locking State Diagram” on
page 27 and Figure 17, “Locking Operations Flowchart” on page 56.
The following concisely summarizes the locking functionality.
5.1.1.1 Locked State
The default state of all blocks upon power-up or reset is locked (states [001] or [101]). Locked
blocks are fully protected from alteration. Any Program or Erase operations attempted on a locked
block will return an error on bit SR[1] of the Status Register. The state of a locked block can be
changed to Unlocked or Lock Down using the appropriate software commands. An Unlocked
block can be locked by writing the Lock command sequence, 0x60 followed by 0x01.
5.1.1.2 Unlocked State
Unlocked blocks (states [000], [100], [110]) can be programmed or erased. All unlocked blocks
return to the Locked state when the device is reset or powered down. The status of an unlocked
block can be changed to Locked or Locked Down using the appropriate software commands. A
Locked block can be unlocked by writing the Unlock command sequence, 0x60 followed by 0xD0.
5.1.1.3 Lock-Down State
Blocks that are Locked-Down (state [011]) are protected from Program and Erase operations (just
like Locked blocks), but their protection status cannot be changed using software commands alone.
A Locked or Unlocked block can be Locked Down by writing the Lock-Down command sequence,
0x60 followed by 0x2F. Locked-Down blocks revert to the Locked state when the device is reset or
powered down.
The Lock-Down function depends on the WP# input pin. When WP# = 0, blocks in Lock Down
[011] are protected from program, erase, and lock status changes. When WP# = 1, the Lock-Down
function is disabled ([111]) and Locked-Down blocks can be individually unlocked by software
command to the [110] state, where they can be erased and programmed. These blocks can then be
relocked [111] and unlocked [110] as required while WP# remains high. When WP# goes low,
blocks that were previously Locked Down return to the Lock-Down state [011], regardless of any
changes made while WP# was high. Device reset or power-down resets all blocks, including those
in Lock-Down, to Locked state.
5.2 Reading Block-Lock Status
The Lock status of each block can be read in read-identifier mode of the device by issuing the read-
identifier command (0x90). Subsequent reads at Block Address + 0x00002 will output the Lock
status of that block. The Lock status is represented by DQ0 and DQ1. DQ0 indicates the Block
Lock/Unlock status and is set by the Lock command and cleared by the Unlock command. It is also
automatically set when entering Lock Down. DQ1 indicates Lock-Down status, and is set by the
Lock-Down command. It cannot be cleared by software—only by device reset or power-down. See
Table 6, “Device Identification Codes” on page 20 for block-status information.
Intel
£
Advanced+ Boot Block Flash Memory (C3)
Datasheet 29
5.3 Locking Operations during Erase Suspend
Changes to block-lock status can be performed during an erase-suspend by using the standard
locking command sequences to Unlock, Lock, or Lock Down a block. This is useful in the case
when another block needs to be updated while an Erase operation is in progress.
To change block locking during an Erase operation, first issue the Erase Suspend command (0xB0),
then check the status register until it indicates that the Erase operation has been suspended. Next,
write the preferred Lock command sequence to a block and the Lock status will be changed. After
completing any preferred Lock, Read, or Program operations, resume the Erase operation with the
Erase Resume command (0xD0).
If a block is Locked or Locked Down during a Suspended Erase of the same block, the locking
status bits will be changed immediately. But when the Erase is resumed, the Erase operation will
complete.
Locking operations cannot be performed during a Program Suspend. Refer to Appendix A, “Write
State Machine States” on page 50 for detailed information on which commands are valid during
Erase Suspend.
5.4 Status Register Error Checking
Using nested-locking or program-command sequences during Erase Suspend can introduce
ambiguity into status register results.
Since locking changes are performed using a two-cycle command sequence, e.g., 0x60 followed by
0x01 to lock a block, following the Block Lock, Block Unlock, or Block Lock-Down Setup
command (0x60) with an invalid command will produce a Lock-Command error (SR[4] and SR[5]
will be set to 1) in the Status Register. If a Lock-Command error occurs during an Erase Suspend,
SR[4] and SR[5] will be set to 1 and will remain at 1 after the Erase is resumed. When Erase is
complete, any possible error during the Erase cannot be detected via the status register because of
the previous Lock-Command error.
A similar situation happens if an error occurs during a Program-Operation error nested within an
Erase Suspend.
5.5 128-Bit Protection Register
The C3 device architecture includes a 128-bit protection register than can be used to increase the
security of a system design. For example, the number contained in the protection register can be
used to “match” the flash component with other system components, such as the CPU or ASIC,
preventing device substitution. The Intel application note,
AP-657 Designing with the Advanced+
Boot Block Flash Memory Architecture,
contains additional application information.
The 128 bits of the protection register are divided into two 64-bit segments. One of the segments is
programmed at the Intel factory with a unique 64-bit number, which is unchangeable. The other
segment is left blank for customer designs to program, as preferred. Once the customer segment is
programmed, it can be locked to prevent further programming.
Intel
£
Advanced+ Boot Block Flash Memory (C3)
30 Datasheet
5.5.1 Reading the Protection Register
The protection register is read in the read-identifier mode. The device is switched to this mode by
issuing the Read Identifier command (0x90). Once in this mode, read cycles from addresses shown
in Figure 6, “Protection Register Mapping” retrieve the specified information. To return to read-
array mode, issue the Read Array command (0xFF).
5.5.2 Programming the Protection Register
The protection register bits are programmed using the two-cycle Protection Program command.
The 64-bit number is programmed 16 bits at a time. First, issue the Protection Program Setup
command, 0xC0. The next write to the device will latch in address and data, and program the
specified location. The allowable addresses are shown in Table 6, “Device Identification Codes” on
page 20.SeeFigure 18, “Protection Register Programming Flowchart” on page 57. Attempts to
address Protection Program commands outside the defined protection register address space should
not be attempted. Attempting to program to a previously locked protection register segment will
result in a Status Register error (Program Error bit SR[4] and Lock Error bit SR[1] will be set to 1).
5.5.3 Locking the Protection Register
The user-programmable segment of the protection register is lockable by programming bit 1 of the
PR-LOCK location to 0. See Figure 6, “Protection Register Mapping” on page 30.Bit0ofthis
location is programmed to 0 at the Intel factory to protect the unique device number. This bit is set
using the Protection Program command to program 0xFFFD to the PR-LOCK location. After these
bits have been programmed, no further changes can be made to the values stored in the protection
register. Protection Program commands to a locked section will result in a Status Register error
(Program Error bit SR[4] and Lock Error bit SR[1] will be set to 1). Protection register lockout
state is not reversible.
5.6 V
PP
Program and Erase Voltages
The C3 device provides in-system programming and erase in the 1.65 V–3.6 V range. For fast
production programming, 12 V programming can be used. Refer to Figure 7, “Example Power
Supply Configurations” on page 31.
Figure 6. Protection Register Mapping
0x88
0x85
64-bit Segment
(User-Programmable)
0x84
0x81
0x80
PR Lock Register 0
64-bit Segment
(Intel Factory-Programmed)
15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0
128-Bit Protection Register 0