SLOS412C − APRIL 2003 − REVISED MARCH 2004
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage, V
CC+
±18 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage (any input) ±15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Differential input voltage, V
ID
±30 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output current ±50 mA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Notes 1 and 2):D package 97°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . .
P package 85°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
PW package 149°C/W. . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−60°C to 125°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
2. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions
MIN MAX UNIT
V
CC+
2 16
V
CC−
Supply voltage
−2 −16
V
V
ICR
Input common-mode voltage range −13.5 13.5 V
T
A
Operating free-air temperature range −40 85 °C
electrical characteristics, V
CC±
= ±15 V, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
V
IO
Input offset voltage R
S
≤ 10 kΩ 0.5 3 mV
I
IO
Input offset current 5 200 nA
I
IB
Input bias current 100 500 nA
A
VD
Large-signal differential-voltage amplification R
L
≥ 2 kΩ, V
O
= ±10 V 90 110 dB
V
OM
Output voltage swing R
L
≥ 2 kΩ ±12 ±13.5 V
V
ICR
Common-mode input voltage range ±12 ±13.5 V
CMRR Common-mode rejection ratio R
S
≤ 10 kΩ 80 110 dB
k
SVR
‡
Supply-voltage rejection ratio R
S
≤ 10 kΩ 80 110 dB
I
CC
Supply current (all amplifiers) 6 9 mA
‡
Measured with V
CC±
varied simultaneously
operating characteristics, V
CC±
= ±15 V, T
A
= 25°C (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP UNIT
SR Slew rate at unity gain R
L
≥ 2 kΩ 5 V/µs
GBW Gain-bandwidth product f = 10 kHz 12 MHz
THD Total harmonic distortion V
O
= 5 V, R
L
= 2 kΩ, f = 1 kHz, A
VD
= 20 dB 0.0005%
V
n
Equivalent input noise voltage RIAA, R