![](//files.rcfreelance.com/pdf//lm139awrqmlv/bg7.png)
LM139AQML, LM139QML
www.ti.com
SNOSAH8G –FEBRUARY 2005–REVISED MARCH 2013
LM139A 883, QMLV & RH, SMD 5962–9673801 Electrical Characteristics DC
Parameters
(1)(2)
(continued)
The following conditions apply, unless otherwise specified. +V = 5V, V
CM
= 0V
Symbol Parameters Conditions Sub-
Notes Min Max Unit
groups
V
CM
Common Mode Voltage Range +V = 30V See
(4)
V
+
-
0 V 1
See
(5)
(1.5)
See
(4)
V
+
-
0 V 2, 3
See
(5)
(2.0)
V
Diff
Differential Input Voltage +V = 30V, -V =0V, +V
I
= 36V, -V
I
=
(6)
500 nA 1, 2, 3
0V
+V = 30V, -V = 0V, +V
I
= 0V, -V
I
=
(6)
500 nA 1, 2, 3
36V
(4) The input common-mode voltage or either input signal voltage should not be allowed to go negative by more than 0.3V. The upper end
of the common-mode voltage range is V
+
−1.5V for Subgroup 1, or V
+
−2.0V for Subgroup 2 & 3. Either or both inputs can go to +30
V
DC
without damage, independent of the magnitude of V
+
.
(5) Parameter ensured by V
IO
tests
(6) The value for V
Diff
is not data logged during Read and Record.
LM139A 883, QMLV & RH, SMD 5962–9673801 Electrical Characteristics AC Parameters
(1)(2)
The following conditions apply, unless otherwise specified. +V = 5V
Symbol Parameters Conditions Sub-
Notes Min Max Unit
groups
t
RLH
Response Time V
OD
= 5mV 5.0 µS 4
V
OD
= 50mV 0.8 µS 4
t
RHL
Response Time V
OD
= 5mV 2.5 µS 4
V
OD
= 50mV 0.8 µS 4
(1) Pre and post irradiation limits are identical to those listed under AC and DC electrical characteristics except as listed in the “Post
Radiation Limits” table. These parts may be dose rate sensitive in a space environment and demonstrate enhanced low dose rate effect.
Radiation end point limits for the noted parameters are ensured only for the conditions as specified in Mil-Std-883, Method 1019,
Condition A.
(2) Low dose rate testing has been performed on a wafer-by-wafer basis, per test method 1019, condition D, MIL-STD-883, with no
enhanced low dose rate sensitivity (ELDRS) effect. Pre and post irradiation limits are identical to those listed under AC and DC electrical
characteristics, except as listed in the “Post Radiation Limits” table. Radiation end point limits for the noted parameters are ensured for
only the conditions as specified in MIL-STD-883, Method 1019, condition D.
LM139A 883, QMLV & RH, SMD 5962–9673801 Electrical Characteristics DC Parameters Delta
Values
The following conditions apply, unless otherwise specified. +V = 5V, V
CM
= 0V
Deltas required for S-Level, MLS (as specified on Internal Processing instructions (IPI)), and QMLV product at Group B,
Subgroup 5.
Symbol Parameters Conditions Sub-
Notes Min Max Unit
groups
V
IO
Input Offset Voltage -1.0 1.0 mV 1
± I
Bias
Input Bias Current V
O
= 1.5V See
(1)
-15 15 nA 1
I
IO
Input Offset Current V
O
= 1.5V -10 +10 nA 1
(1) The direction of the input current is out of the IC due to the PNP input stage. This current is essentially constant, independent of the
state of the output so no loading change exists on the reference or input lines.
Copyright © 2005–2013, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: LM139AQML LM139QML