5
Switching Specifications C
L
= 50pF, Input t
r
, t
f
= 6ns
PARAMETER SYMBOL
TEST
CONDI-
TIONS
V
CC
(V)
25
o
C -40
o
C TO 85
o
C -55
o
C TO 125
o
C
UNITSMIN TYP MAX MIN TYP MAX MIN TYP MAX
HC TYPES
Propagation Delay t
PLH
, t
PHL
C
L
= 50pF
Data to Outputs
HC240
2 - - 100 - - 125 - - 150 ns
4.5 - - 20 - - 25 - - 30 ns
C
L
= 15pF 5 - 8 - - - ----ns
C
L
= 50pF 6 - - 17 - - 21 - - 26 ns
Data to Outputs
HC241
t
PLH
, t
PHL
C
L
= 50pF 2 - - 110 - - 140 - - 165 ns
4.5 - - 22 - - 28 - - 33 ns
C
L
= 15pF 5 - 9 - - - ----ns
C
L
= 50pF 6 - - 19 - - 24 - - 28 ns
Data to Outputs
HC244
t
PLH
, t
PHL
C
L
= 50pF 2 - - 110 - - 140 - - 165 ns
4.5 - - 22 - - 28 - - 33 ns
C
L
= 15pF 5 - 9 - - - ----ns
C
L
= 50pF 6 - - 19 - - 24 - - 28 ns
Output Enable and Disable
Time
t
THL
, t
TLH
C
L
= 50pF 2 - - 150 - - 190 - - 225 ns
4.5 - - 30 - - 38 - - 45 ns
5-12-------ns
6 - -26- -33- -38ns
Output Transition Time t
TLH
, t
THL
C
L
= 50pF 2 - - 60 - - 75 - - 90 ns
4.5 - - 12 - - 15 - - 18 ns
6 - -10- -13- -15ns
Input Capacitance C
I
C
L
= 50pF - 10 - 10 - - 10 - - 10 pF
Three-State Output
Capacitance
C
O
C
L
= 50pF - - - 20 - - 20 - - 20 pF
Power Dissipation Capacitance
(Notes 3, 4)
C
PD
C
L
= 15pF
HC240 5 - 38 - - - ----pF
HC241 5 - 34 - - - ----pF
HC244 5 - 46 - - - ----pF
HCT TYPES
Propagation Delay
Data to Outputs
HCT240
t
PHL,
t
PLH
C
L
= 50pF 4.5 - - 22 - - 28 - - 33 ns
C
L
= 15pF 5 - 9 - - - ----ns
Data to Outputs
HCT241
t
PHL,
t
PLH
C
L
= 50pF 4.5 - - 25 - - 31 - - 38 ns
C
L
= 15pF 5 - 10 - - - ----ns
Data to Outputs
HCT244
t
PHL,
t
PLH
C
L
= 50pF 4.5 - - 25 - - 31 - - 38 ns
C
L
= 15pF 5 - 10 - - - ----ns
CD54/74HC240, CD54/74HCT240, CD74HC241, CD54/74HCT241, CD54/74HC244, CD54/74HCT244