13
bq2031
Impedance
Symbol Parameter Minimum Typical Maximum Unit Notes
R
BATZ
BAT pin input impedance 50 - - M
Ω
R
SNSZ
SNS pin input impedance 50 - - M
Ω
R
TSZ
TS pin input impedance 50 - - M
Ω
R
PROG1
Soft-programmed pull-up or pull-down
resistor value (for programming)
--10
k
Ω
DSEL, TSEL, and
QSEL
R
PROG2
Pull-up or pull-down resistor value - - 3 k
Ω
IGSEL
R
MTO
Charge timer resistor 20 - 480 k
Ω
Timing (T
A
= T
OPR
;V
CC
= 5V
±
10%)
Symbol Parameter Minimum Typical Maximum Unit Notes
t
MTO
Charge time-out range 1 - 24 hours See Figure 9
t
QT1
Pre-charge qual test 1 time-out period - 0.02t
MTO
--
t
QT2
Pre-charge qual test 2 time-out period - 0.16t
MTO
--
t
DV
∆
2
V termination sample frequency - 0.008t
MTO
--
t
H01
Pre-charge qual test 2 hold-off period - 0.002t
MTO
--
t
H02
Bulk charge hold-off period - 0.015t
MTO
--
F
PWM
PWM regulator frequency range - 100 kHz See Equation 9
Capacitance
Symbol Parameter Minimum Typical Maximum Unit
C
MTO
Charge timer capacitor - 0.1 0.1
µ
F
C
PWM
PWM R-C capacitance - 0.001 -
µ
F