DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

ProASIC3 DC and Switching Characteristics
2-2 v1.3
Table 2-2 • Recommended Operating Conditions
1
Symbol Parameter Commercial Industrial Units
T
A
Ambient temperature 0 to +70
4,6
–40 to +85
5,6
°C
V
CC
1.5 V DC core supply voltage 1.425 to 1.575 1.425 to 1.575 V
V
JTAG
JTAG DC voltage 1.4 to 3.6 1.4 to 3.6 V
V
PUMP
Programming voltage Programming Mode 3.15 to 3.45 3.15 to 3.45 V
Operation
3
0 to 3.6 0 to 3.6 V
V
CCPLL
Analog power supply (PLL) 1.4 to 1.6 1.4 to 1.6 V
V
CCI
and VMV
2
1.5 V DC supply voltage 1.425 to 1.575 1.425 to 1.575 V
1.8 V DC supply voltage 1.7 to 1.9 1.7 to 1.9 V
2.5 V DC supply voltage 2.3 to 2.7 2.3 to 2.7 V
3.3 V DC supply voltage 3.0 to 3.6 3.0 to 3.6 V
LVDS/B-LVDS/M-LVDS differential I/O 2.375 to 2.625 2.375 to 2.625 V
LVPECL differential I/O 3.0 to 3.6 3.0 to 3.6 V
Notes:
1. All parameters representing voltages are measured with respect to GND unless otherwise specified.
2. The ranges given here are for power supplies only. The recommended input voltage ranges specific to each
I/O standard are given in Table 2-18 on page 2-19. VMV and V
CCI
should be at the same voltage within a
given I/O bank.
3. V
PUMP
can be left floating during operation (not programming mode).
4. Maximum T
J
= 85°C.
5. Maximum T
J
= 100°C.
6. To ensure targeted reliability standards are met across ambient and junction operating temperatures, Actel
recommends that the user follow best design practices using Actel’s timing and power simulation tools.
Table 2-3 • Flash Programming Limits – Retention, Storage and Operating Temperature
1
Product Grade
Programming
Cycles
Program Retention
(biased/unbiased)
Maximum Storage
Temperature T
STG
(°C)
2
Maximum Operating
Junction Temperature T
J
(°C)
2
Commercial 500 20 years 110 100
Industrial 500 20 years 110 100
Notes:
1. This is a stress rating only; functional operation at any condition other than those indicated is not implied.
2. These limits apply for program/data retention only. Refer to Table 2-1 on page 2-1 and Table 2-2 for device
operating conditions and absolute limits.
ProASIC3 DC and Switching Characteristics
v1.3 2-3
I/O Power-Up and Supply Voltage Thresholds for Power-On Reset
(Commercial and Industrial)
Sophisticated power-up management circuitry is designed into every ProASIC
®
3 device. These
circuits ensure easy transition from the powered-off state to the powered-up state of the device.
The many different supplies can power up in any sequence with minimized current spikes or surges.
In addition, the I/O will be in a known state through the power-up sequence. The basic principle is
shown in Figure 2-1 on page 2-4.
There are five regions to consider during power-up.
ProASIC3 I/Os are activated only if ALL of the following three conditions are met:
1. V
CC
and V
CCI
are above the minimum specified trip points (Figure 2-1 on page 2-4).
2. V
CCI
> V
CC
– 0.75 V (typical)
3. Chip is in the operating mode.
V
CCI
Trip Point:
Ramping up: 0.6 V < trip_point_up < 1.2 V
Ramping down: 0.5 V < trip_point_down < 1.1 V
V
CC
Trip Point:
Ramping up: 0.6 V < trip_point_up < 1.1 V
Ramping down: 0.5 V < trip_point_down < 1 V
V
CC
and V
CCI
ramp-up trip points are about 100 mV higher than ramp-down trip points. This
specifically built-in hysteresis prevents undesirable power-up oscillations and current surges. Note
the following:
During programming, I/Os become tristated and weakly pulled up to V
CCI
.
JTAG supply, PLL power supplies, and charge pump V
PUMP
supply have no influence on I/O
behavior.
PLL Behavior at Brownout Condition
Actel recommends using monotonic power supplies or voltage regulators to ensure proper power-
up behavior. Power ramp-up should be monotonic at least until V
CC
and V
CCPLLX
exceed brownout
activation levels. The V
CC
activation level is specified as 1.1 V worst-case (see Figure 2-1 on page 2-4
for more details).
When PLL power supply voltage and/or V
CC
levels drop below the V
CC
brownout levels (0.75 V ±
0.25 V), the PLL output lock signal goes low and/or the output clock is lost. Refer to the
Table 2-4 • Overshoot and Undershoot Limits
1
V
CCI
and VMV
Average V
CCI
–GND Overshoot or Undershoot
Duration as a Percentage of Clock Cycle
2
Maximum Overshoot/
Undershoot
2
2.7 V or less 10% 1.4 V
5% 1.49 V
3 V 10% 1.1 V
5% 1.19 V
3.3 V 10% 0.79 V
5% 0.88 V
3.6 V 10% 0.45 V
5% 0.54 V
Notes:
1. Based on reliability requirements at 85°C.
2. The duration is allowed at one out of six clock cycles. If the overshoot/undershoot occurs at one out of two
cycles, the maximum overshoot/undershoot has to be reduced by 0.15 V.
3. This table does not provide PCI overshoot/undershoot limits.
ProASIC3 DC and Switching Characteristics
2-4 v1.3
Power-Up/-Down Behavior of Low-Power Flash Devices chapter of the handbook for information
on clock and lock recovery.
Internal Power-Up Activation Sequence
1. Core
2. Input buffers
Output buffers, after 200 ns delay from input buffer activation
Figure 2-1 • I/O State as a Function of V
CCI
and V
CC
Voltage Levels
Region 1: I/O buffers are OFF
Region 2: I/O buffers are ON.
I/Os are functional (except differential inputs)
but slower because V
CCI
/V
CC
are below
specification. For the same reason, input
buffers do not meet V
IH
/V
IL
levels, and
output buffers do not meet V
OH
/V
OL
levels.
Min V
CCI
datasheet specification
voltage at a selected I/O
standard; i.e., 1.425 V or 1.7 V
or 2.3 V or 3.0 V
V
CC
V
CC
= 1.425 V
Region 1: I/O Buffers are OFF
Activation trip point:
V
a
= 0.85 V ± 0.25 V
Deactivation trip point:
V
d
= 0.75 V ± 0.25 V
Activation trip point:
V
a
= 0.9 V ± 0.3 V
Deactivation trip point:
V
d
= 0.8 V ± 0.3 V
V
CC
= 1.575 V
Region 5: I/O buffers are ON
and power supplies are within
specification.
I/Os meet the entire datasheet
and timer specifications for
speed, V
IH
/V
IL
, V
OH
/V
OL
, etc.
Region 4: I/O
buffers are ON.
I/Os are functional
(except differential
but slower because V
CCI
is
below specification. For the
same reason, input buffers do not
meet V
IH
/V
IL
levels, and output
buffers do not meet V
OH
/V
OL
levels.
Region 4: I/O
buffers are ON.
I/Os are functional
(except differential inputs)
where VT can be from 0.58 V to 0.9 V (typically 0.75 V)
V
CCI
Region 3: I/O buffers are ON.
I/Os are functional; I/O DC
specifications are met,
but I/Os are slower because
the V
CC
is below specification.
V
CC
= V
CCI
+ VT