Functional Description
The AC/ACT163 counts in modulo-16 binary sequence.
From state 15 (HHHH) it increments to state 0 (LLLL). The
clock inputs of all flip-flops are driven in parallel through a
clock buffer. Thus all changes of the Q outputs occur as a
result of, and synchronous with, the LOW-to-HIGH transi-
tion of the CP input signal. The circuits have four funda-
mental modes of operation, in order of precedence:
synchronous reset, parallel load, count-up and hold. Four
control inputs—Synchronous Reset (SR
), Parallel Enable
(PE
), Count Enable Parallel (CEP) and Count Enable
Trickle (CET)—determine the mode of operation, as shown
in the Mode Select Table. A LOW signal on SR
overrides
counting and parallel loading and allows all outputs to go
LOW on the next rising edge of CP. A LOW signal on PE
overrides counting and allows information on the Parallel
Data (P
n
) inputs to be loaded into the flip-flops on the next
rising edge of CP. With PE
and SR HIGH, CEP and CET
permit counting when both are HIGH. Conversely, a LOW
signal on either CEP or CET inhibits counting.
The AC/ACT163 uses D-type edge-triggered flip-flops and
changing the SR
, PE, CEP and CET inputs when the CP is
in either state does not cause errors, provided that the rec-
ommended setup and hold times, with respect to the rising
edge of CP, are observed.
The Terminal Count (TC) output is HIGH when CET is
HIGH and counter is in state 15. To implement synchro-
nous multistage counters, the TC outputs can be used with
the CEP and CET inputs in two different ways.
Figure 1 shows the connections for simple ripple carry, in
which the clock period must be longer than the CP to TC
delay of the first stage, plus the cumulative CET to TC
delays of the intermediate stages, plus the CET to CP
setup time of the last stage. This total delay plus setup time
sets the upper limit on clock frequency. For faster clock
rates, the carry lookahead connections shown in Figure 2
are recommended. In this scheme the ripple delay through
the intermediate stages commences with the same clock
that causes the first stage to tick over from max to min in
the Up mode, or min to max in the Down mode, to start its
final cycle. Since this final cycle takes 16 clocks to com-
plete, there is plenty of time for the ripple to progress
through the intermediate stages. The critical timing that lim-
its the clock period is the CP to TC
delay of the first stage
plus the CEP
to CP setup time of the last stage. The TC
output is subject to decoding spikes due to internal race
conditions and is therefore not recommended for use as a
clock or asynchronous reset for flip-flops, registers or
counters.
Logic Equations: Count Enable = CEP • CET • PE
TC = Q
0
• Q
1
• Q
2
• Q
3
• CET
SR
PE CET CEP Action on the Rising
Clock Edge (
)
L X X X Reset (Clear)
H L X X Load (P
n
→ Q
n
)
H H H H Count (Increment)
H H L X No Change (Hold)
H H X L No Change (Hold)