Freelance Electronics Components Distributor
Question?
800-300-1968
We Stock Hard to Find Parts

A-1001B

Part # A-1001B
Description
Category IC
Availability Out of Stock
Qty 0



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

P1 Relay
The Best Relaytion
ISO
9001
108-98009
Rev. C
EC-JM00-0009-03
ECOC: JM10
1. Aug. 04
1 pole telecom and signal relay, polarized,
Through Hole Type (THT) or
Surface Mount Technology (SMT),
Relay types: non-latching with 1 coil
latching with 2 coils
latching with 1 coil
Features
Directly triggerable with TTL standard modules such
as ALS, HCT and ACT
Slim line 13.5 x 7.85 mm, 0.531 x 0.309 inch
Switching current 1 A
1 changeover contact (1 form C / SPDT)
Bifurcated contacts
Immersion cleanable
High sensitivity results in low nominal power consumption
65 to 130 mW for non-latching
30 to 150 mW for latching
Surge voltage resistance between contact and coil:
- 2.5 kV (2 / 10 µsec) meets the Bellcore Requirement GR-1089
- 1.5 kV (10 / 160 µsec) meets FCC Part 68
Typical applications
Automotive equipment
CAN bus, imobilizer
Office equipment
Measurement and control equipment
Medical equipment
Safety equipment
Options
FCC version on request. Testing of open contacts with surge
voltage in accordance with FCC 68.302 (1.5 kV, 10/160 µsec)
P1 Relay V23026
Basic insulation coil/contacts according to IEC/EN 60950
Clearance > 0.75 mm
Creepage distance > 0.75 mm
UL File No. E 111441
Page 2 (10) 108-98009 Rev. C
European Directive conformance:
P1 relay product conformance according to:
- Directive 2000/53/EC: ELV (End of Life of Vehicles)
- Directive 2002/95/EC: ROHS (Restrictions of the
use of certain hazardous substances in electrical and
electronic equipment)
Compliance is evidenced by written declaration from all raw
material suppliers.
Tyco Electronics AXICOM only has responsibility for the proper
processing of these materials.
Confirmation is valid for date codes ≥ 0429
Dimensions
V23026-x1xxx-B201
THT SMT
mm inch mm inch
L 13.0 ± 0.1 0.512 ± 0.004 13.4 ± 0.1 0.528 ± 0.004
W 7.6 ± 0.1 0.299 ± 0.004 7.75 ± 0.1 0.305 ± 0.004
H 6.9 - 0.2 0.272 - 0.008 8.0 - 0.2 0.315 - 0.008
T 3.5 - 0.2 0.138 -0.008 N/A N/A
T1 N/A N/A 10.9 - 0.5 0.429 - 0.020
T2 5.08 ± 0.15 0.200 ± 0.006 5.08 ± 0.15 0.200 ± 0.006
S 0.3 ± 0.1 0.012 ±0.004 N/A N/A
S1 N/A N/A 0.85 ± 0.1 0.033 ±0.004
S2 N/A N/A 0.2 - 0.15 0.008 ±0.006
P1 Relay V23026
Terminal assignment
Relay - top view
Mounting hole layout
View onto the component side of the PCB
Solder pad layout
View onto the component side of the PCB
Contact release or reset condition, coil polarity to set the relay
THT Version
SMT Version
Latching type, 2 coils
reset condition
Non-latching type,
not energized condition
Latching type, 1 coil
reset condition
Page 3 (10) 108-98009 Rev. C
Contacts are shown in reset
condition. Both coils can be
used either as set or reset coil.
1234NEXT