Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

74HC74AP

Part # 74HC74AP
Description
Category IC
Availability In Stock
Qty 19
Qty Price
1 + $0.09450
Manufacturer Available Qty
TOSHIBA
Date Code: 9229
  • Shipping Freelance Stock: 19
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

TC74HC74AP/AF/AFN
2007-10-01
4
Electrical Characteristics
DC Characteristics
Test Condition Ta = 25°C Ta = 40~85°C
Characteristics Symbol
V
CC
(V)
Min Typ. Max Min Max
Unit
High-level input
voltage
V
IH
2.0
4.5
6.0
1.50
3.15
4.20
1.50
3.15
4.20
V
Low-level input
voltage
V
IL
2.0
4.5
6.0
0.50
1.35
1.80
0.50
1.35
1.80
V
I
OH
= 20 μA
2.0
4.5
6.0
1.9
4.4
5.9
2.0
4.5
6.0
1.9
4.4
5.9
High-level output
voltage
V
OH
V
IN
= V
IH
or
V
IL
I
OH
= 4 mA
I
OH
= 5.2 mA
4.5
6.0
4.18
5.68
4.31
5.80
4.13
5.63
V
I
OL
= 20 μA
2.0
4.5
6.0
0.0
0.0
0.0
0.1
0.1
0.1
0.1
0.1
0.1
Low-level output
voltage
V
OL
V
IN
= V
IH
or
V
IL
I
OL
= 4 mA
I
OL
= 5.2 mA
4.5
6.0
0.17
0.18
0.26
0.26
0.33
0.33
V
Input leakage
current
I
IN
V
IN
= V
CC
or GND 6.0 ±0.1 ±1.0 μA
Quiescent supply
current
I
CC
V
IN
= V
CC
or GND 6.0 2.0 20.0 μA
TC74HC74AP/AF/AFN
2007-10-01
5
Timing Requirements
(input: t
r
= t
f
= 6 ns)
Test Condition Ta = 25°C
Ta
=
40
~85°C
Characteristics Symbol
V
CC
(V) Typ. Limit Limit
Unit
Minimum pulse width
(CK)
t
W (L)
t
W (H)
2.0
4.5
6.0
75
15
13
95
19
16
ns
Minimum pulse width
(
CLR
, PR )
t
W (L)
2.0
4.5
6.0
75
15
13
95
19
16
ns
Minimum set-up time t
s
2.0
4.5
6.0
75
15
13
95
19
16
ns
Minimum hold time t
h
2.0
4.5
6.0
0
0
0
0
0
0
ns
Minimum removal time
(
CLR
, PR )
t
rem
2.0
4.5
6.0
25
5
4
30
6
5
ns
Clock frequency f
2.0
4.5
6.0
6
31
36
5
25
29
MHz
AC Characteristics
(C
L
= 15 pF, V
CC
= 5 V, Ta = 25°C, input: t
r
= t
f
= 6 ns)
Characteristics Symbol Test Condition Min Typ. Max Unit
Output transition time
t
TLH
t
THL
6 12 ns
Propagation delay time
(CK-Q,
Q
)
t
pLH
t
pHL
13 26 ns
Propagation delay time
(
CLR
, PR -Q,
Q
)
t
pLH
t
pHL
14 26 ns
Maximum clock frequency f
max
36 77 MHz
TC74HC74AP/AF/AFN
2007-10-01
6
AC Characteristics
(C
L
= 50 pF, input: t
r
= t
f
= 6 ns)
Test Condition Ta = 25°C Ta = 40~85°C
Characteristics Symbol
V
CC
(V)
Min Typ. Max Min Max
Unit
Output transition time
t
TLH
t
THL
2.0
4.5
6.0
30
8
7
75
15
13
95
19
16
ns
Propagation delay
time
(CK-Q,
Q
)
t
pLH
t
pHL
2.0
4.5
6.0
48
16
13
150
30
26
190
38
32
ns
Propagation delay
time
(
CLR
, PR -Q,
Q
)
t
pLH
t
pHL
2.0
4.5
6.0
51
17
15
150
30
26
190
38
32
ns
Maximum clock
frequency
f
max
2.0
4.5
6.0
6
31
36
21
63
67
5
25
29
MHz
Input capacitance C
IN
5 10 10 pF
Power dissipation
capacitance
C
PD
(Note) 34 pF
Note: C
PD
is defined as the value of the internal equivalent capacitance which is calculated from the operating
current consumption without load.
Average operating current can be obtained by the equation:
I
CC
(opr) = C
PD
V
CC
f
IN
+ I
CC
/2 (per F/F)
PREVIOUS1234NEXT