OP470
Very low noise, quad, operational amplifier
ASD0013059 Rev. B 25-Sep-07 Page 3 of 5
Table I - Electrical Characteristics (continued)
Parameter Symbol
Conditions
1/
Sub-
groups
Limit
Min
Limit
Max
Units
Output Voltage Swing 4/ V
OP
R
L
= 2Kohm 4, 5, 6, ±12 V
No Load 1, 2, 3 11
Supply Current 2/ I
SY
M, D, L, R 1 11
mA
Input Voltage Range 4/ IVR 1, 2, 3 ±11 V
Slew Rate 4/ SR
A
VLC
= +21, R
L
= 10kΩ
7 1.4
V/μV
1 110
Common Mode Rejection 4/ CMR V
CM
= IVR 3/
2, 3 100
dB
1 1.8
Power Supply Rejection
Ratio 4/
PSRR V
S
= ±4.5V to ±18V
2, 3 5.6
μV/V
Table I Notes:
1/ V
S
= ±15V, R
S
= 50Ω, unless otherwise specified.
2/ I
SY
limit equals the total of all four amplifiers.
3/ IVR is defined as the V
CM
range used for the CMR test.
4/ Not tested Post Irradiation.
4.1 Electrical Test Requirements:
Table II
Test Requirements
Subgroups (in accordance with
MIL-PRF-38535, Table III)
Interim Electrical Parameters 1
Final Electrical Parameters 1, 2, 3, 4, 5, 6 1/ 2/
Group A Test Requirements 1, 2, 3, 4, 5, 6, 7
Group C end-point electrical parameters 1, 2, 3 2/
Group D end-point electrical parameters 1
Group E end-point electrical parameters 1
1/ PDA applies to Subgroup 1 only. Delta's excluded from PDA.
2/
See Table III for delta parameters. See table I for conditions.
4.2 Life Test and Burn-In Delta Limits:
Table III
TEST BURN-IN LIFETEST DELTA
TITLE ENDPOINT ENDPOINT LIMIT UNITS
V
IO
±0.4 ±0.5 ±0.1 mV
I
IB
±25 ±30 ±5 nA
I
IO
±10 ±15 ±5 nA