Part # V300A12T400BL
Description CONVERTER MOD DC/DC 12V 400W
Category CONVERTER
Availability In Stock
Qty 1
Qty Price
1 + $343.71721
Manufacturer Available Qty
Vicor Corporation
  • Shipping Freelance Stock: 1
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 300V Maxi Family Rev. 8.7 Page 7 of 13
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Unit Notes
Efficiency 87 88.4 % Nominal input; full load; 25°C
Ripple and noise 240 300 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 17.1 19 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 13.9 Amps
Current limit 14.1 16 18.8 Amps Output voltage 95% of nominal
Short circuit current 9.73 16 18.8 Amps Output voltage <250 mV
36 Vout, 500 W (e.g. V300A36C500BL)
Parameter Min Typ Max Unit Notes
Efficiency 87 88.2 % Nominal input; full load; 25°C
Ripple and noise 135 169 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 40.4 41.9 43.4 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 11.3 13.2 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 11.1 Amps
Current limit 11.3 12.8 15 Amps Output voltage 95% of nominal
Short circuit current 7.77 12.8 15 Amps Output voltage <250 mV
36 Vout, 400 W (e.g.V300A36C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 87.5 89 % Nominal input; full load; 25°C
Ripple and noise 100 125 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 53.7 55.7 57.7 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 12.6 13.3 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 10.4 Amps
Current limit 10.7 12.1 14.1 Amps Output voltage 95% of nominal
Short circuit current 7.35 12.1 15.1 Amps Output voltage <250 mV
48 Vout, 500 W (e.g. V300A48C500BL)
Parameter Min Typ Max Unit Notes
Efficiency 87 88.3 % Nominal input; full load; 25°C
Ripple and noise 280 350 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 53.7 55.7 57.7 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 15.4 16.4 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 8.3 Amps
Current limit 8.49 9.58 11.3 Amps Output voltage 95% of nominal
Short circuit current 5.83 9.58 11.3 Amps Output voltage <250 mV
48 Vout, 400 W (e.g. V300A48C400BL)
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 300V Maxi Family Rev. 8.7 Page 8 of 13
Set your site on VICOR at vicorpower.com
Module Enable/Disable
The module may be disabled by pulling PC below 2.3 V with
respect to the –Input. This may be done with an open collector
transistor, relay, or optocoupler. Multiple converters may be
disabled with a single transistor or relay either directly or via
“OR’ing” diodes. See Figure 1.
Primary Auxiliary Supply
At 5.7 V, PC can source up to 1.5 mA. In the example shown
in Figure 3, PC powers a module enabled LED.
Module Alarm
The module contains “watchdog” circuitry which monitors
input voltage, operating temperature and internal operating
parameters. In the event that any of these parameters are
outside of their allowable operating range, the module will
shut down and PC will go low. PC will periodically go high
and the module will check to see if the fault (as an example,
overtemperature) has cleared. If the fault has not been cleared,
PC will go low again and the cycle will restart. The SC pin
will go low in the event of a fault and return to its normal
state after the fault has been cleared. See Figures 2 and 4.
+IN
PC
PR
–IN
Disable
Disable = PC <2.3 V
Figure 1 Module enable/disable.
Figure 3 LED on-state indicator.
+IN
PC
PR
–IN
4 kΩ
"Module
Enabled"
+IN
PC
PR
–IN
Optocoupler
4 kΩ
Alarm
1.00V
+OUT
+S
SC
–S
–OUT
Comparator
+OUT
+S
SC
–S
– OUT
+IN
PC
PR
–IN
Input Undervoltage
2-20 ms typ.
f (V
IN
)
Auto
Restart
5.7 Vdc
(0-3 mA)
50 Ω
SW2
SW3
1.23
Vdc
6 K
1 K
SW1
SW1, 2, & 3
shown in
"Fault" position
Input Overvoltage (See Note 1)
Overtemperature
Module Faults
1
Not applicable for 300 Vdc input family
1 M
Figure 2 PC/SC module alarm logic.
Figure 5 Isolated on-state indicator.
2–20 ms typical
Fault
SC
PC
1.23 V
5.7 V
40 μs typ.
Figure 4 PC/SC module alarm timing.
Figure 6 Secondary side on-state indicator.
CONTROL FUNCTIONS - PC PIN
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 300V Maxi Family Rev. 8.7 Page 9 of 13
Set your site on VICOR at vicorpower.com
Output Voltage Programming
The output voltage of the converter can be adjusted or
programmed via fixed resistors, potentiometers or voltage
DACs. See Figures 7 and 8.
Figure 8 Output voltage trim up circuit.Figure 7 Output voltage trim down circuit.
+OUT
+S
SC
–S
–OUT
R
U
Trim Up
Load
Error
Amp
1 kΩ
1.23 V
0.033 μF
1,000 (Vout –1.23) Vnom
1.23 (Vout – Vnom)
R
U
(ohms) =
– 1,000
Load
+OUT
+S
SC
–S
–OUT
R
D
Trim Down
Error
Amp
1 kΩ
1.23 V
0.033 μF
1,000 Vout
Vnom Vout
R
D
(ohms) =
Trim Down
1. This converter is not a constant power device – it has a
constant current limit. Hence, available output power is
reduced by the same percentage that output voltage is
trimmed down. Do not exceed maximum rated output current.
2. The trim down resistor must be connected to the –Sense pin.
CONTROL FUNCTIONS - SC PIN
Trim Up
1. The converter is rated for a maximum delivered power. To
ensure that maximum rated power is not exceeded, reduce
maximum output current by the same percentage increase in
output voltage.
2. The trim up resistor must be connected to the +Sense pin.
3. Do not trim the converter above maximum trim range
(typically +10%) or the output over voltage protection
circuitry may be activated.
Trim resistor values calculated automatically:
On-line calculators for trim resistor values are available
on the vicor website at:
vicorpower.com/tools.
Resistor values can be calculated for fixed trim up,
fixed trim down and for variable trim up or down.
In addition to trimming information, the web site and
the Applications Manual also include design tips,
applications circuits, EMC suggestions, thermal design
guidelines and PDF data sheets for all available Vicor
products.