Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

V300A12T400BL

Part # V300A12T400BL
Description CONVERTER MOD DC/DC 12V 400W
Category CONVERTER
Availability In Stock
Qty 1
Qty Price
1 + $343.71721
Manufacturer Available Qty
Vicor Corporation
  • Shipping Freelance Stock: 1
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 300V Maxi Family Rev. 8.7 Page 4 of 13
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Unit Notes
Efficiency 72.5 74 % Nominal input; full load; 25°C
Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 2.7 2.8 2.9 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 7.9 8.1 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 80 Amps
Current limit 81.6 92 112 Amps Output voltage 95% of nominal
Short circuit current 56 92 112 Amps Output voltage <250 mV
MODULE SPECIFIC OPERATING SPECIFICATIONS
2 Vout, 160 W (e.g. V300A2C160BL)
Parameter Min Typ Max Unit Notes
Efficiency 79 81 % Nominal input; full load; 25°C
Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 4.14 4.3 4.46 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 8.1 9.4 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 80 Amps
Current limit 81.6 92 112 Amps Output voltage 95% of nominal
Short circuit current 56 92 112 Amps Output voltage <250 mV
3.3 Vout, 264 W (e.g. V300A3V3C264BL)
Parameter Min Typ Max Unit Notes
Efficiency 78.1 79.6 % Nominal input; full load; 25°C
Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 4.14 4.3 4.46 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 6.2 12 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 60.6 Amps
Current limit 61.8 69.7 81.9 Amps Output voltage 95% of nominal
Short circuit current 42.4 69.7 81.9 Amps Output voltage <250 mV
3.3 Vout, 200 W (e.g. V300A3V3C200BL)
Parameter Min Typ Max Unit Notes
Efficiency 81.5 83 % Nominal input; full load; 25°C
Ripple and noise 100 125 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 6.03 6.25 6.47 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 6.2 9.3 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 80 Amps
Current limit 81.6 92 112 Amps Output voltage 95% of nominal
Short circuit current 56 92 112 Amps Output voltage <250 mV
5 Vout, 400 W (e.g. V300A5C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 83.2 84.2 % Nominal input; full load; 25°C
Ripple and noise 150 188 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 6.03 6.25 6.47 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 8.1 8.5 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 60 Amps
Current limit 61.2 69 81 Amps Output voltage 95% of nominal
Short circuit current 42 69 81 Amps Output voltage <250 mV
5 Vout, 300 W (e.g. V300A5C300BL)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 300V Maxi Family Rev. 8.7 Page 5 of 13
Set your site on VICOR at vicorpower.com
MODULE SPECIFIC OPERATING SPECIFICATIONS (CONT.)
Parameter Min Typ Max Unit Notes
Efficiency 85 86 % Nominal input; full load; 25°C
Ripple and noise 280 350 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 13.7 14.3 14.9 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 8 12 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 41.6 Amps
Current limit 42.5 48 60.5 Amps Output voltage 95% of nominal
Short circuit current 29.1 48 60.5 Amps Output voltage <250 mV
12 Vout, 500 W (e.g. V300A12C500BL)
Parameter Min Typ Max Unit Notes
Efficiency 82 83 % Nominal input; full load; 25°C
Ripple and noise 320 400 mV p-p; Nominal input; full load; 20MHz bandwith
Output OVP setpoint 9.36 9.7 10.1 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 14.6 16 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 50 Amps
Current limit 51 57.5 67.5 Amps Output voltage 95% of nominal
Short circuit current 35 57.5 67.5 Amps Output voltage <250 mV
8 Vout, 400 W (e.g. V300A8C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 82 84.8 % Nominal input; full load; 25°C
Ripple and noise 250 313 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 9.36 9.7 10.1 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 8.9 10 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Output Current 0 37.5 Amps
Current limit 38.2 43.1 50.7 Amps Output voltage 95% of nominal
Short circuit current 26.2 43.1 50.7 Amps Output voltage <250 mV
8 Vout, 300 W (e.g. V300A8C300BL)
Parameter Min Typ Max Unit Notes
Efficiency 84.5 85.8 % Nominal input; full load; 25°C
Ripple and noise 220 275 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 13.7 14.3 14.9 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 12.7 14.1 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 33.3 Amps
Current limit 33.9 38.3 45 Amps Output voltage 95% of nominal
Short circuit current 23.3 38.3 45 Amps Output voltage <250 mV
12 Vout, 400 W (e.g. V300A12C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 84 86 % Nominal input; full load; 25°C
Ripple and noise 200 250 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 8 12 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 33.3 Amps
Current limit 34 38.4 43.5 Amps Output voltage 95% of nominal
Short circuit current 23.3 38.4 43.5 Amps Output voltage <250 mV
15 Vout, 500 W (e.g. V300A15C500BL)
Vicor Corp. Tel: 800-735-6200, 978-470-2900 Fax: 978-475-6715 300V Maxi Family Rev. 8.7 Page 6 of 13
Set your site on VICOR at vicorpower.com
Parameter Min Typ Max Unit Notes
Efficiency 87 88 % Nominal input; full load; 25°C
Ripple and noise 80 100 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 10.1 10.5 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 17.8 Amps
Current limit 18.2 20.6 24.2 Amps Output voltage 95% of nominal
Short circuit current 12.5 20.6 24.2 Amps Output voltage <250 mV
28 Vout, 500 W (e.g. V300A28C500BL)
Parameter Min Typ Max Unit Notes
Efficiency 85.5 87 % Nominal input; full load; 25°C
Ripple and noise 160 200 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 31.5 32.7 33.9 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 14.8 16.8 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 14.3 Amps
Current limit 14.5 16.4 19.4 Amps Output voltage 95% of nominal
Short circuit current 10 16.4 19.4 Amps Output voltage <250 mV
28 Vout, 400 W (e.g. V300A28C400BL)
Parameter Min Typ Max Unit Notes
Efficiency 84.8 86.3 % Nominal input; full load; 25°C
Ripple and noise 150 188 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 10.9 17.5 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 16.6 Amps
Current limit 17 19.2 22.6 Amps Output voltage 95% of nominal
Short circuit current 11.6 19.2 22.6 Amps Output voltage <250 mV
24 Vout, 400 W (e.g. V300A24C400BL)
MODULE SPECIFIC OPERATING SPECIFICATIONS
Parameter Min Typ Max Unit Notes
Efficiency 87 89 % Nominal input; full load; 25°C
Ripple and noise 100 125 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 27.1 28.1 29.1 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 9.8 13 Watts No load
Load regulation ±0.02 ±0.3 % No load to full load; nominal input
Load current 0 20.8 Amps
Current limit 21.3 24 27.2 Amps Output voltage 95% of nominal
Short circuit current 14.6 24 27.2 Amps Output voltage <250 mV
24 Vout, 500 W (e.g. V300A24C500BL)
Parameter Min Typ Max Unit Notes
Efficiency 81.4 83.4 % Nominal input; full load; 25°C
Ripple and noise 320 400 mV p-p; Nominal input; full load; 20 MHz bandwith
Output OVP setpoint 17.1 17.8 18.5 Volts 25°C; recycle input voltage to restart (>100 ms off)
Dissipation, standby 11.3 18.1 Watts No load
Load regulation ±0.02 ±0.2 % No load to full load; nominal input
Load current 0 26.6 Amps
Current limit 27.2 30.7 36.1 Amps Output voltage 95% of nominal
Short circuit current 18.6 30.7 36.1 Amps Output voltage <250 mV
15 Vout, 400 W (e.g. V300A15C400BL)
PREVIOUS12345NEXT