2 Tyco Electronics Corp.
Data Sheet
July 2000
18 Vdc to 36 Vdc Input, 3.3 Vdc Output; 165 W
FC250F1 Power Module: dc-dc Converter;
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow fuse with a maximum rating of 25 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
Parameter Symbol Min Max Unit
Input Voltage (continuous) V
I
— 50 Vdc
I/O Isolation Voltage (for 1 minute) — — 1500 Vdc
Operating Case Temperature
(See Thermal Considerations section and
Figure 18.)
T
C
–40 100 °C
Storage Temperature T
stg
–55 125 °C
Parameter Symbol Min Typ Max Unit
Operating Input Voltage V
I
18 28 36 Vdc
Maximum Input Current (V
I
= 0 V to 36 V) I
I, max
— — 15 A
Inrush Transient i
2
t — — 4.0 A
2
s
Input Reflected-ripple Current, Peak-to-peak
(5 Hz to 20 MHz, 12 µH source impedance;
see Figure 8.)
I
I
— 10 — mAp-p
Input Ripple Rejection (120 Hz) — — 60 — dB