Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

FC250F1

Part # FC250F1
Description DC/DC Power Supply Single-OUT3.3V 50A 165W
Category CONVERTER
Availability In Stock
Qty 1
Qty Price
1 + $4.08183
Manufacturer Available Qty
Tyco Electronics
  • Shipping Freelance Stock: 1
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

Data Sheet
July 2000
FC250F1 Power Module: dc-dc Converter;
18 Vdc to 36 Vdc Input, 3.3 Vdc Output; 165 W
The FC250F1 Power Module uses advanced, surface-mount
technology and delivers high-quality, compact, dc-dc
conversion at an economical price.
Applications
Redundant and distributed power architectures
Computer equipment
Communications equipment
Options
Heat sinks available for extended operation
Features
Size: 61.0 mm x 116.8 mm x 13.5 mm
(2.40 in. x 4.60 in. x 0.53 in.)
Wide input voltage range
High efficiency: 78% typical
Parallel operation with load sharing
Adjustable output voltage
Overtemperature protection
Output voltage set-point adjustment (trim)
Synchronization
Power good signal
Output current monitor
Output overvoltage and overcurrent protection
Remote sense
Remote on/off
Constant frequency
Case ground pin
Input-to-output isolation
ISO
* 9001 Certified manufacturing facilities
UL
1950
Recognized,
CSA
C22.2 No. 950-95
Certified, and
VDE
§
0805 (EN60950, IEC950)
Licensed
Description
The FC250F1 Power Module is a dc-dc converter that operates over an input voltage range of 18 Vdc to 36 Vdc
and provides a precisely regulated dc output. The outputs are fully isolated from the inputs, allowing versatile
polarity configurations and grounding connections. The module has a maximum power rating of 165 W at a typ-
ical full-load efficiency of 78%.
Two or more modules may be paralleled with forced load sharing for redundant or enhanced power applications.
The package, which mounts on a printed-circuit board, accommodates a heat sink for high-temperature
applications.
*
ISO
is a registered trademark of the International Organization of Standardization.
UL
is a registered trademark of Underwriters Laboratories, Inc.
CSA
is a registered trademark of Canadian Standards Association.
§VDE is a trademark of Verband Deutscher Elektrotechniker e.V.
2 Tyco Electronics Corp.
Data Sheet
July 2000
18 Vdc to 36 Vdc Input, 3.3 Vdc Output; 165 W
FC250F1 Power Module: dc-dc Converter;
Absolute Maximum Ratings
Stresses in excess of the absolute maximum ratings can cause permanent damage to the device. These are abso-
lute stress ratings only. Functional operation of the device is not implied at these or any other conditions in excess
of those given in the operations sections of the data sheet. Exposure to absolute maximum ratings for extended
periods can adversely affect device reliability.
Electrical Specifications
Unless otherwise indicated, specifications apply over all operating input voltage, resistive load, and temperature
conditions.
Table 1. Input Specifications
Fusing Considerations
CAUTION: This power module is not internally fused. An input line fuse must always be used.
This encapsulated power module can be used in a wide variety of applications, ranging from simple stand-alone
operation to an integrated part of a sophisticated power architecture. To preserve maximum flexibility, internal fus-
ing is not included; however, to achieve maximum safety and system protection, always use an input line fuse. The
safety agencies require a normal-blow fuse with a maximum rating of 25 A (see Safety Considerations section).
Based on the information provided in this data sheet on inrush energy and maximum dc input current, the same
type of fuse with a lower rating can be used. Refer to the fuse manufacturer’s data for further information.
Parameter Symbol Min Max Unit
Input Voltage (continuous) V
I
50 Vdc
I/O Isolation Voltage (for 1 minute) 1500 Vdc
Operating Case Temperature
(See Thermal Considerations section and
Figure 18.)
T
C
–40 100 °C
Storage Temperature T
stg
–55 125 °C
Parameter Symbol Min Typ Max Unit
Operating Input Voltage V
I
18 28 36 Vdc
Maximum Input Current (V
I
= 0 V to 36 V) I
I, max
15 A
Inrush Transient i
2
t 4.0 A
2
s
Input Reflected-ripple Current, Peak-to-peak
(5 Hz to 20 MHz, 12 µH source impedance;
see Figure 8.)
I
I
10 mAp-p
Input Ripple Rejection (120 Hz) 60 dB
Tyco Electronics Corp. 3
Data Sheet
July 2000
18 Vdc to 36 Vdc Input, 3.3 Vdc Output; 165 W
FC250F1 Power Module: dc-dc Converter;
Electrical Specifications
(continued)
Table 2. Output Specifications
* Consult your sales representative or the factory.
These are manufacturing test limits. In some situations, results may differ.
Parameter Symbol Min Typ Max Unit
Output Voltage Set Point
(V
I
= 28 V; I
O
= I
O, max
; T
C
= 25 °C)
V
O, set
3.25 3.3 3.35 Vdc
Output Voltage
(Over all operating input voltage, resistive load,
and temperature conditions until end of life; see
Figure 10 and Feature Descriptions.)
V
O
3.20 3.40 Vdc
Output Regulation:
Line (V
I
= 18 V to 36 V)
Load (I
O
= I
O, min
to I
O, max
)
Temperature (T
C
= –40 °C to +100 °C)
0.01
0.05
15
0.1
0.2
50
%V
O
%V
O
mV
Output Ripple and Noise Voltage
(See Figures 4 and 9.):
RMS
Peak-to-peak (5 Hz to 20 MHz)
40
150
mVrms
mVp-p
External Load Capacitance 0 * µF
Output Current
(At I
O
< I
O, min
, the modules may exceed output
ripple specifications.)
I
O
0.5 50 A
Output Current-limit Inception
(V
O
= 90% of V
O, set
; see Feature Descriptions.)
I
O, cli
51.5 57.5 65
%I
O, max
Output Short-circuit Current
(V
O
= 1.0 V; indefinite duration, no hiccup mode;
see Figure 2.)
150 %I
O, max
Efficiency
(V
I
= 28 V; I
O
= I
O, max
; T
C
= 25 °C;
see Figures 3 and 10.)
η
—78—%
Switching Frequency 500 kHz
Dynamic Response
(
I
O
/
t = 1 A/10 µs, V
I
= 28 V, T
C
= 25 °C; tested
with a 10 µF aluminum and a 1.0 µF ceramic
capacitor across the load; see Figures 5 and 6.):
Load Change from I
O
= 50% to 75% of I
O, max
:
Peak Deviation
Settling Time (V
O
< 10% of peak deviation)
Load Change from I
O
= 50% to 25% of I
O, max
:
Peak Deviation
Settling Time (V
O
< 10% of peak deviation)
50
200
50
200
mV
µs
mV
µs
1234567NEXT