Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

DFC10U24D12

Part # DFC10U24D12
Description DC/DC PS DUAL-OUT 12V/-12V 0.4A/-0.4A 10W 5PIN - Bulk
Category CONVERTER
Availability Out of Stock
Qty 0
Qty Price
1 + $71.68517



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

1
DFC10 SERIES
DUAL OUTPUT
DESCRIPTION
The dual output DFC10 Series provides power solutions to meet
commercial and industrial requirements. With power densities
above 11 watts per cubic inch (0.67 watts per cm
3
), overcurrent
protection, and five sided shielded case, the DFC10 meets rigorous
needs in an industry standard case size. The 120KHz operating
frequency of the DFC10 Series allows an increased power density
while including adequate heat sinking and input/output filtering.
This eliminates the need for external components in most
applications. Full overload protection is provided by pulse-by-pulse
current limiting on models with 48V input.
FEATURES
High Power Density, up to 11 Watts per Cubic Inch
Efficiencies to 79%
Fully Isolated, Fully Filtered Design
Greater than 700V Isolation
Overcurrent Protection
Five-Side Shielded Copper Case
Ultra Wide Range Input (4:1)
NOTES
(1) All parameters measured at Tc = 25°C, nominal input voltage and full rated load unless otherwise noted.
Refer to the Technical Reference Section for the definition of terms, measurement circuits and other
information.
(2) Case is tied to the COMMON output pin.
(3) The functional temperature range is intended to give an additional data point for use in evaluating this
power supply. At the low functional temperature the power supply will function with no side effects,
however, sustained operation at the high functional temperature will reduce expected operational life.
The data sheet specifications are not guaranteed beyond the case operating range.
(4) The case thermal impedance is specified as the case temperature rise over ambient per package watt
dissipated.
1
BOTTOM VIEW SIDE VIEW
3
4
5
2
0.800
0.61
0.000
0.42
0.000
0.3
0.300
0.100
0.000
0.200
0.500
0.61
1.02
2.02
(20.32)
(15.5)
(2.54)
(15.5)
(5.08)
(7.62)
(12.70)
(51.31)
(25.91)
(10.67)
(7.62)
0.040 (1.02)
DIA TYP
Mechanical tolerances unless otherwise noted:
X.XX dimensions: ±0.03 inches
X.XXX dimensions: ±0.005 inches
Rev. 04/2000
NUCLEAR AND MEDICAL APPLICATIONS Power-One products are not authorized for use as critical components in life support systems, equipment used in hazardous environments,
or nuclear control systems without the express written consent of the President of Power-One, Inc.
TECHNICAL REVISIONS The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are
subject to change without notice.
2
NOTES
(1) All parameters measured at Tc = 25°C, nominal input voltage and full rated load unless otherwise
noted. Refer to the Technical Reference Section for the definition of terms, measurement circuits
and other information.
(2) Noise is measured per Technical Reference Section. Measurement bandwidth is 0-20 MHz. RMS
noise is measured over a 0.01-1 MHz bandwidth. To simulate standard PCB decoupling practices,
output noise is measured with a 10µf tantalum and 0.01µF ceramic capacitor located 1 inch away
from the converter.
(3) The converter may be safely operated at any load from zero to the full rating. Dynamic response of
the converter may degrade if the converter is operated with less than 25% output load.
(4) Load regulation is defined for loading/unloading both outputs simultaneously. Load range is 25 to
100%.
(5) Cross regulation is defined for loading/unloading one output while the other output is kept at
full load. Load range is 25 to 100%.
(6) Short term stability is specified after a 30 minute warmup at full load, constant line and
recording the drift over a 24 hour period.
DFC10 SERIES APPLICATION NOTES:
External Capacitance Requirements
No external capacitance is required for operation of the DFC10
Series. If a capacitive input source is farther than 1” from the
converter, an additional capacitor may be required at the input
pins for proper operation. This input capacitor should have an
ESR greater than 0.25 ohms. Input capacitors with an ESR less
than 0.25 ohms may cause peaking of the input filter and actually
degrade circuit performance.
External output capacitance is not required for operation,
however it is recommended that 1F to 10F of tantalum and
0.001 to 0.1F ceramic capacitance be selected for reduced system
noise. Additional output capacitance may be added for increased
filtering, but should not exceed 400F.
DFC10 SERIES – DUAL OUTPUT
3
2.5
2.0
1.0
1.5
0.5
0.0
020
1510
100% LOAD
50% LOAD
5253035 40
INPUT CURRENT Vs. INPUT VOLTAGE
LINE INPUT (VOLTS)
INPUT CURRENT (AMPS)
85
80
70
60
75
65
55
040
3020
LINE = 36VDC
LINE = 9VDC
LINE = 24VDC
10 50 60 70 80 90 100
EFFICIENCY Vs. LOAD
LOAD (%)
EFFICIENCY (%)
24 Volt Input
Typical Performance:
(Tc=25°C, Vin=Nom VDC,
Rated Load)
48 Volt Input
Typical Performance:
(Tc=25°C, Vin=Nom VDC,
Rated Load)
90
80
85
75
70
65
60
824
28 322016
100% FULL LOAD
50% FULL LOAD
12 36
EFFICIENCY Vs. LINE INPUT VOLTAGE
LINE INPUT (VOLTS)
EFFICIENCY (%)
1.0
0.8
0.4
0.6
0.2
0.0
824
28 322016
100% LOAD
75% LOAD
50% LOAD
12 36
RMS INPUT CURRENT Vs. LINE INPUT
LINE INPUT (VDC)
RMS INPUT CURRENT (AMPS)
90
85
80
75
70
040
3020
LINE = 72VDC
LINE = 18VDC
LINE = 48VDC
10 50 60 70 80 90 100
EFFICIENCY Vs. LOAD
LOAD (%)
EFFICIENCY (%)
0.8
0.4
0.6
0.2
0.0
15 55
654535
100% LOAD
75% LOAD
50% LOAD
25 75
RMS INPUT CURRENT Vs. LINE INPUT
LINE INPUT (VOLTS)
RMS INPUT CURRENT (AMPS)
DFC10 SERIES – DUAL OUTPUT
50
6
8
10
60 70 80 90 100
OUTPUT POWER DERATING
AMBIENT TEMPERATURE
POWER OUTPUT
1.0
0.8
0.4
0.6
0.2
0.0
040
3020
100% LOAD
50% LOAD
10 50 60 70 80
INPUT CURRENT Vs. INPUT VOLTAGE
LINE INPUT (VOLTS)
INPUT CURRENT (AMPS)
90
85
80
75
70
15 55
654535
100% FULL LOAD
50% FULL LOAD
25 75
EFFICIENCY Vs. LINE INPUT VOLTAGE
LINE INPUT (VOLTS)
EFFICIENCY (%)