CC10-4812SR-E

Part # CC10-4812SR-E
Description CONV DC/DC 10W SNGL 48V 12V SMD 7-PIN DIP
Category CONVERTER
Availability Out of Stock
Qty 0
Qty Price
1 + $34.53813



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.


1
CC3-0505SF-E
■ Features

 

󰮏

  






CC-E
■ Product Line up
InsulationtypeDC-DCconverter
■ Applications
Y
E
A
R
S
warranty
5
■ Model-naming method










   














  

  

  

  

 
 

 

 

 
 
 

 

 

 
 
 

 

 

 
 
 

 

 

 

 
  

      

  
 
  

      

  
 
  

      

  
 
  

      

  

 
 

       
 
 

       
 
 

       
 
 

       

 
 

       
 
 

 

 

 
 
 

 

 

 
 
 

 

 

 
  
 

 
  
 

 



UL60950-1/
CSAC22.2No.60950-1
LowVoltageDirective
Electrical Appliance
andMaterialSafetyLaw
(Input Voltage 100VAC)
DENAN
Builttomeet
EN60950-1
医 療 計 測 F A 半導体 その他
の他
ks
コンータ
通 信 F A 半導体
その他
ph
pf-a
hk-a
hws
alpha
dlp
fps
フォーマット
コンータ
通 信 F A 半導体
その他
ンピータ
通 信 医 療 計 測 F A 半導体
コンュー
通 信 医 療 計 測 F A 半導体
コンュー
通 信 医 療 計 測 F A 半導体
コンュー
通 信 医 療 計 測 F A 半導体
  
    
     


Conformity to RoHS Directive
UL60950-1/
CSAC22.2No.60950-1
LowVoltageDirective
Electrical Appliance
andMaterialSafetyLaw
(Input Voltage 100VAC)
DENAN
Builttomeet
EN60950-1
001-01/20080421/etl_cc_e

2
CC1R5-E Specifications
MODEL
ITEMS/UNITS
CC1R5-0503Sx-E CC1R5-0505Sx-E
CC1R5-0512Sx-E CC1R5-0512Dx-E
Input
Nominal Voltage V DC5.0
Voltage Range V DC4.5-9.0
Efficiency (typ) (*1) 71 77 80 79
Current (typ) (*1) A 0.372 0.390 0.375 0.380
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature40C to +50C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) 3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Temperature -40 to +85
Storage Temperature -40 to +85
Operating Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M󰮌 min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25C.
(*2) The maximum output power value is between -40C and +50C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC1R5-1203Sx-E CC1R5-1205Sx-E
CC1R5-1212Sx-E CC1R5-1212Dx-E
Input
Nominal Voltage V DC12
Voltage Range V DC9.0-18
Efficiency (typ) (*1) 73 78 82 81
Current (typ) (*1) A 0.151 0.160 0.152 0.154
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature40C to +50C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) 3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4 - 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Temperature -40 to +85
Storage Temperature -40 to +85
Operating Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M󰮌 min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25C.
(*2) The maximum output power value is between -40C and +50C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
CC1R5-E

3
MODEL
ITEMS/UNITS
CC1R5-2403Sx-E CC1R5-2405Sx-E
CC1R5-2412Sx-E CC1R5-2412Dx-E
Input
Nominal Voltage V DC24
Voltage Range V DC18-36
Efficiency (typ) (*1) 72 77 81 79
Current (typ) (*1) A 0.076 0.081 0.077 0.079
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature40C to +50C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) 3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Temperature -40 to +85
Storage Temperature -40 to +85
Operating Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M󰮌 min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25C.
(*2) The maximum output power value is between -40C and +50C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.
MODEL
ITEMS/UNITS
CC1R5-4803Sx-E CC1R5-4805Sx-E
CC1R5-4812Sx-E CC1R5-4812Dx-E
Input
Nominal Voltage V DC48
Voltage Range V DC36-76
Efficiency (typ) (*1) 70 76 80 79
Current (typ) (*1) A 0.039 0.041 0.039 0.040
Output
Nominal Voltage
VDC
3.3 5 12 15 12 15
Maximum Current A 0.400 0.300 0.125 0.100 0.060 0.050
Maximum Power (*2) W 1.32 1.5
Maximum Line Regulation (Within input voltage range)
mV 20 40 80
Maximum Load Regulation (0-100% load) (*3)
mV 40 100 600
Temperature Coefficient
(Ambient temperature40C to +50C)
80mV 200mV 300mV
Max Power Total Regulation (max) (*4) 3 5
Maximum Ripple & Noise (typ/max) (*5)
mVp-p
40/120 30/120
Voltage Adjustable Range
VDC
3.15-3.6 4.75-6.0 11.4-15.0 11.4- 15.0
Function
Over Current Protection (*6) Available
Over Voltage Protection Not available
Remote ON/OFF Control Available
Environment
Operating Temperature -40 to +85
Storage Temperature -40 to +85
Operating Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Storage Humidity
RH
5-95 (the conditions of maximum 38C in wet bulb temperature and non-condensation should be ensured.)
Vibration 10-55Hz, 15 minutes sweep and 1.52mm total amplitude, 3 directions, 2h for each
Shock 980m/s² (100G), 6ms, 6 directions, 3 times for each, in non-operation
Isolation
Withstand Voltage
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VAC (for 1 minute)
Isolation Resistance
Between input terminal and case, between input terminal and output terminal, and between output terminal and case: 500VDC, 50M󰮌 min
Standards
Safety Standards UL60950-1, CSA C22.2 No.60950-1 (C-UL), EN60950-1 (NEMKO)
Mechanical
Weight (typ) g 3.2
Size (W x H x D) mm DIP: 16.51 x 8.5 x 16.6 / SMD: 16.51 x 8.8 x 16.6
Note: "x" in model names is to be replaced by a symbol which represents the terminal configuration (F: DIP/R: SMD) for actual model names.
Note: With nominal input/output voltage, maximum output current, and Ta=25C, if not specified separately.
Note: For 12V/ 12V models, output power can be set to 15V/ 15V by connecting the output adjustment terminal TRM to -Vout.
Note: For 12V model, output voltage can be set to 24V or 30V single output by making the COM terminal open.
(*1) With nominal input voltage, maximum output current, and Ta=25C.
(*2) The maximum output power value is between -40C and +50C. For use in outside this temperature range, derating is needed.
(*3) In balanced load for dual outputs ( "balanced load" means a condition where the +output and -output of load current are equal).
(*4) Output voltage includes input change, load change (balanced load), and temperature change.
(*5) In 50MHz, Ta=25C.
(*6) Output current restriction method. Automatically resumes when the causes are removed. Never operate the unit under output-shorted or overload conditions for over 30
seconds.