Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

031-9174-004

Part # 031-9174-004
Description Contact SKT Crimp ST Cable Mount - Bulk (Alt: 031-9174-004
Category CONTACT
Availability In Stock
Qty 14
Qty Price
1 - 2 $6.29387
3 - 5 $5.00648
6 - 8 $4.72040
9 - 11 $4.38663
12 + $3.90983
Manufacturer Available Qty
ITT CANNON
Date Code: 1042
  • Shipping Freelance Stock: 7
    Ships Immediately
ITT CANNON
Date Code: 1042
  • Shipping Freelance Stock: 7
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

ARINC 404 DPX*MA Crimp
Coaxial Cable Assembly Recommendations
64
www.ittcannon.com
Dimensions shown in inch (mm)
Specifications and dimensions subject to change
LITTLE CAESAR Contact Assembly Data
For Codes G, H and R
For Codes F, S and T
1
. Strip and trim cable as shown on page 60.
2
. Solder inner conductor to coaxial contact with crimp ring over braid and rear insulator over inner
conductor.
3
. Insert cable into coaxial with shell under braid. Crimp ring with Cannon crimp tool CA58073.
1
. Strip and trim cable as shown on page 60.
2
. Solder inner connector to coaxial contact with crimp ring pushed back on cable.
3
. Insert cable into coaxial and pull ring forward over braid. Crimp ring with Cannon crimp tool
CA58073-0001 or CCT-408M. After crimping, crimp ring must not exceed .252 (6.40) diameter.
1. Strip and trim cable as shown on page 60.
2. Slide crimp ring over braid and jacket of cable.
3. Unbraid exposed portion of braid and fold braid wires backward over outside of crimp ring.
4. Insert prepared wire into right angle fitting of shell assembly. Conductor should be aligned in slot of the
center contact. Crimp with Cannon tool CCT/C10.
5
. Solder center conductor of cable to contact. Insert cap and solder in place.
1
. Slip ferrule over cable jacket. Trim outer jacket. Comb out braid as shown. Retrim braid.
2. Bend up combed out braid at right angles to cable. Slide ferrule up to bend and fold braid back against
ferrule.
3. Slide rear insulator over dielectric as shown. Press insulator firmly against folded back braid and trim
dielectric flush with insulator. Then cut inner conductor to length shown.
4. Place contact over conductor. Press contact and insulator firmly against braid and solder contact to
conductor.
5. Push cable assembly into shell, pressing against rear of ferrule and crimp area shown with T. & B.
#WT-400 Crimp Tool while making sure parts do not move out of place.
1 . Trim jacket to .680 (17.27)/.660 (16.76) dimension. Then slide ferrule over braid until it stops
against jacket, and comb out exposed portion of braid.
2. Fold combed braid over ferrule as shown. Then trim dielectric to .070 (1.78)/.060 (1.52) dimension
and slide rear insulator over dielectric until it presses against braid.
3. Press insulator against braid and trim inner conductor to .247 (6.27)/.237 (6.02) dimension. Then place
contact over conductor and crimp with MS3191-3 (do not use MS3191-1). Press parts firmly
against locator during crimping operation.
4. Place front insulator over contact. Push parts into coaxia! shell. While holding parts firmly against stop
shoulder in coaxial shell, place jaw of crimp tool at back end of shell and crimp. Use Buchanan crimp
tool #612991 (.343 [8.71) across hex].
FERRULE
CRIMP AREA
S
HELL
C
ONTACT
REAR INSULATOR
JACKET
FERRULE
DIELECTRIC
JACKET
COAXIAL SHELL
REAR INSULATOR
CONTACT
FRONT
INSULATOR
.400 APPROX.
(10-16)
.680 (17.27)
.660 (16.76)
.198 (5.03)
.034 DIA.
(0.86)
.156 (3.96)
.136 (3.45)
.
250 (6.35)
.230 (5.84)
.070 (1.78)
.060 (1.52)
.247 (6.27)
.237 (6.02)
.070 (1.78) MAX.
For Codes U
For Codes AA
For Codes AC
ARINC 404 DPX*MA Crimp
Coaxial Cable Assembly Recommendations (Continued)
65
www.ittcannon.com
Dimensions shown in inch (mm)
Specifications and dimensions subject to change
For Code V
1. Trim cable to dimensions shown below.
A. Push ferrule under braid as far as it will go and press braid down tightly around ferrule.
B. Solder ends of braid to ferrule by applying a small amount of solder. Avoid excess solder as it would
cause braid to swell up.
C. Remove any solder exceeding the .349 (8.86) max. diameter.
D. Check the .075 (1.90) max. dielectric extension, retrim if necessary.
3
. A. Place rear insulator over dielectric and conductor into contact.
B. Solder contact to conductor through access hole.
C. Remove excess solder from outside of contact.
4. A. Place front insulator over contact.
B. Push parts into coaxial shell.
C. While holding parts firmly against stop shoulder in coaxial shell, place jaw of crimp tool at back end
of shell and crimp, use Buchanan crimp tool #612991 [.343 (8.71) across hex].
F
or Codes AB, AD, AE, AF and AG
S
etp 1 - Trim cable as shown.
S
tep 2 - Flare out ends of braid to permit entry of ferrule.
S
tep 3 - Complete termination per instructions as shown below.
a
. Push ferrule under braid as far as it will go. Trim off braid extending beyond shoulder of ferrul, if
necessary.
b. While holding ferrule in place pull crimp sleeve forward over braid until it is tight against shoulder on
ferrule. Push firmly against face of ferrule to make sure it is up tight.
c. Trim dielectric to the .035 (0.89)/ .030 (0.76) dimension.
d. Carefully push inner conductor through rear insulator.
e. While holding rear insulator firmly against ferrule, trim conductor to .156 (3.96)/.146 (3.71)
dimension.
f. Place contact over conductor and solder.
g. Place front insulator over contact and then push assembly into coaxial shell.
h. Place parts in jaw of crimp tool. Locate jaws at start of chamfer on crimp sleeve. Press
Sleeve firmly into coaxial shell and crimp. Use Daniels crimp tool HX4-210.
Code
Letter
A
B, C, D & P
E
F
G
H & R
J
K
L
S
U
V
T
AA, AC
AB, AD, AE, AF, AG
.420/.400
.420/.400
.420/.400
.785/.745
.490/.470
.581/.561
.326/.306
.410/.390
.385/.365
.678/.658
.940/.920
.550/.540
.598/.578
.432/.415
.460/.440
.480/.460
.275/.255
.275/.255
.345/.325
.250/.230
.290/.270
.244/.224
.275/.255
.760/.740
.415/.405
.300/.280
.330/.310
.330/.310
.330/.310
.228/.208
.156/.136
.156/.136
.088/.068
.088/.068
.074/.064
.156/.136
.080/.060
.250/.240
.228/.208
See page 60 for dimensions
See page 60 for dimensions
.10.67/10.16
10.67/10.16
10.67/10.16
19.94/18.92
12.45/11.94
14.76/14.25
8.28/7.77
10.41/9.91
9.78/9.27
17.22/16.71
23.88/23.37
13.97/13.72
15.19/14.68
11.05/10.54
11.68/11.18
12.19/11.68
6.98/6.48
6.98/6.48
8.76/8.26
6.35/5.84
7.37/6.86
6.20/5.69
6.98/6.48
19.30/18.80
10.54/10.29
7.62/7.11
8.38/7.87
8.38/7.87
8.38/7.87
5.79/5.28
3.96/3.45
3.96/3.45
2.24/1.73
2.24/1.73
1.88/1.63
3.96/3.45
2.03/1.52
6.35/6.10
5.79/5.28
INNER CONDUCTOR
CRIMP AREA
REAR INSULATOR
C
ONTACT
C
rimp Sleeve
.
400 APPROX.
(
10.16)
FRONT INSULATOR
0.75 MAX.
(1.90)
.349 DIA. MAX
(
8.86)
SOLDER ALL AROUND
F
ERRULE
FERRULE
.
156 (3.96)
.146 (3.71)
.
035 (0.89)
.030 (0.76)
.260 (6.60)
.
250 (6.35)
.610 (15.49)
.590 (14.99)
FRONT INSULATOR
C
OAXIAL SHELL
.350 APPROX
(
8.89)
DIELECTRIC
BRAID
JACKET
C
A
B
Inches Millimeters
AB C AB C
Cable T
rim Dimensions
DPXA Modifications Codes
- 4. Mounting holes .120 (3.05) dia. c'sink 100˚ to .225 (5.72) dia.
-
5. 4-40 clinch nuts.
- 6. Removable insert retainer plate.
- 7. Mounting holes .120 (3.05) dia. c'sink 82 to .230 (5.84) dia.
-
12. Mounting holes .132 (3.35)/.125 (3.18).
-
16. A106 insert with separator.
-
17. With grommet and mounting holes .120 (3.05) dia. countersunk 100˚ to .225 (5.72) dia.
-
70. Standard mounting with (LIF) contacts.
-
77. Same as -7 except with low insertion force (LIF) contacts (for LIF contact data).
DPXB and DPX2/3/4 Modification Codes
Some of the modification numbers used in the DPX only certain types. The following chart gives the type in which they may be used (-33 is for plug
lines apply to all types and some are applicable for modification number, the description, and the shell shells, -34 is for receptacle shells).
DPX2-33 and 34
DPX2-33A
DPX2-33F and 34F
DPX2-33M and 34M
DPX2-34A
DPX2-33B
DPXB-33
DPX3-33
DPX4-33
DPX2-34B
DPXB-34
DPX3-34
DPX4-34
DPX2-33 and 34
DPX2-33A
DPX2-34A
DPX2-33F and 34F
DPX2-33M-34M
DPX2-34B/33B
DPXB-34
DPX3-34
DPX4-34
DPX2-33 and 34
DPX2-33A
DPX2-34A
DPX2-33F and 34F
DPX2-33M and 34M
DPX2-33B and 34B
DPXB-33 and 34
DPX3-33 and 34
DPX4-33 and 34
DPXBME-33 and 34
DPX2ME-33 and 34
DPX3ME-33 and 34
DPX4ME-33 and 34
DPX2-33 and 34
DPX2-33A
DPX2-33F and 34F
DPX2-33M and 34M
DPXB-33 and 34
DPX3-33 and 34
DPX4-33 and 34
Standard construction, mounting holes .120 (3.05) dia.
and with tabs for junction shells.
Standard construction - six floating eyelets
and tabs for junction shells,
Standard construction, mounting holes .120 (3.05) dia.
countersunk 82˚ to .230 (5.84) dia. - no tabs.
Standard construction, mounting holes 120 (3.05) dia. - no tabs.
Standard construction and with standard junction shells.
With four #4-40 clinch nuts in mounting holes.
With six #4-40 clinch nuts in mounting holes.
With ten #440 clinch nuts in mounting holes.
Standard construction and with 9junction shells.
Standard construction and with tabs for attaching junction shells.
Standard construction and with tabs for attaching junction shells.
Mounting holes .120 (3.05) dia. countersunk 100˚ to .230(5.84) dia.
- 00**
- 00
- 00
- 00
- 01
- 01
- 01
- 01
- 02
- 02
- 02
- 03
Modification
DESCRIBES STANDARD
CONNECTOR HOUSING
#
4-40 CLINCH NUTS
#4-40 THREAD
(2 TABS PER
RETAINING
PLATE)
Applicable for all MA, ME, NA & NE Series Connectors.
Applicable to NE Series also.
MODIFICATION 00
MODIFICATION 01
MODIFICATION 02
ATTACHING TABS
MODIFICATION 03
ALTERNATE STYLE
Applicable Series Definition
1
1
1
1
1
2
1
1
1
MOUNTING HOLES
.120 (3.05) DIA.
C'SUNK 100 TO
.230 (5.84) DIA.
ARINC 404 DPX
Modifications Codes
66
www.ittcannon.com
Dimensions shown in inch (mm)
Specifications and dimensions subject to change
PREVIOUS1516171819202122232425262728NEXT