Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

030-2097-002

Part # 030-2097-002
Description CONN CONT PIN 1 POS CRMP ST 1TERM - Bulk
Category CONTACT
Availability Out of Stock
Qty 0
Qty Price
1 + $1.70768



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

29
www.ittcannon.com
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
Cannon KJL/KJ/KJA/KJB
MIL-DTL-38999 Series I, II, III Connectors
Tools - Crimp
Tools - Plastic
Tools - Metal (MS)
C
ontact
Size
C
rimp Tool
Part Number
L
ocator or Turret
Part Number
C
rimp Tool
Part Number
L
ocator or Turret
Part Number
C
rimp Tool
Part Number
L
ocator or Turret
Part Number
P
in Contact
Series I/II/III
S
ocket Contact
Series II
S
ocket Contact
Series I & III
M
22520/1-01 CBT-530 M22520/2-01 CBT-565
22D or 22M*
22*
2
0
1
6
1
2
M22520/2-01
M22520/2-01
M
22520/1-01
M
22520/1-01
M
22520/1-01
M22520/2-01
M22520/2-01
M
22520/1-01
M
22520/1-01
M
22520/1-01
M22520/2-09
M22520/2-09
M
22520/1-04 OR TH 187
M
22520/1-04 OR TH 187
M
22520/1-04
M22520/2-01
M22520/2-01
M
22520/1-01
M
22520/1-01
M
22520/1-01
M22520/2-06
M22520/2-06
M
22520/1-04
M
22520/1-04
M
22520/1-04
M22520/2-07
M22520/2-07
M
22520/1-04
M
22520/1-04
M
22520/1-04
I
nner Conductor Crimp Tool Crimp Tool Locator
RG180 M22520/2-01 995-0002-268
RG 174, 179, 316 M22520/2-01 995-0002-268
R
G 142 M22520/2-01 995-0002-268
O
uter Conductor Crimp Tool Crimp Tool Locator
RG180 M22520/5-01 M22520/5-39B
RG 174, 179, 316 M22520/5-01 M22520/5-37B
R
G 142 M22520/5-01 M22520/5-19B
* For reference only
8 Coax
Inner Conductor Crimp Tool Crimp Tool Locator
R
G174, 179, 316 M22520/2-01 M22520/2-34
12 Coax
O
uter Conductor Crimp Tool Crimp Tool Locator
RG174, 179, 316 M22520/31-01 M22520/31-02
Crimp Tool Crimp Tool Locator
Center Contact M22520/2-01 K709
Intermediate Contact M22520/5-01 Y631 Die Closure B
Outer Contact M22520/5-01 Y631 Die Closure A
8 Twinax
Contact
Size
Cannon
Description
Cannon
Part Number
M81969
Part Number
Insertion
Color Tip
Extraction
Color Tip
Superseded
Military
Part Number
22D
22M*
20
16
12
8 Coax/Twinax
12 Coax
CIET-22D-01
CIET-22D-01
CIET-20-10
CIET-16-03
CIET-12-04
CET8-T
CIET-12-04
274-7048-000
274-7048-000
274-7001-000
274-7002-000
274-7003-000
323-7004-001
274-7003-000
M81969/14-01
M81969/14-01
M81969/14-10
M81969/14-03
M81969/14-04
M81969/14-04
MS27534-22D
MS27534-22D
MS27534-20
MS27534-16
MS27534-12
M527534-12
Green
Green
Red
Blue
Yellow
Yellow
White
White
Orange
White
White
White
Insertion tool not required for size 8
Insertion
Insertion
Extraction
Extraction
No.1 No.2
Contact
Size
MS27495
Part Number
ITT CANNON
Part Number
Color
Band
MS27495
Part Number
ITT CANNON
Part Number
Color Band
22D OR 22M*
22*
20
16
Band No. 1 indicates tool size.
Band No. 2 indicates removal tool.
For reference only*
MS27495 A22M
MS27495 A22
MS27495 A20
MS27495 A16
995-0001-718
995-0001-720
995-0001-716
995-0001-732
995-0001-719
995-0001-721
995-0001-717
995-0001-731
Black
Brown
Red
Blue
White
White
White
White
MS27495 R22M
MS27495 R22
MS27495 R20
MS27495 R16
Black
Brown
Red
Blue
Insertion/Extraction
30
www.ittcannon.com
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
C
annon KJL/KJ/KJA/KJB
MIL-DTL-38999 Series I, II, III Connectors
Wire Stripping
Wire Size A
2
2D or 22M*
2
0
16
12
*
For reference only
A
.
125 (3.18)
.
188 (4.77)
.188 (4.77)
.188 (4.77)
S
trip insulation from end of wire to be crimped.
(See table for proper stripping dimensions.) Do not
cut or damage wire strands.
VISUAL INSPECTION HOLE
1. Insert stripped wire into contact crimp pot.
Wire must be visible thru inspection hole.
3
. Release crimped contact and wire from tool. Be
certain the wire is visible thru inspection hole in
contact.
2. Using correct crimp tool and locator, cycle the tool once to be sure the indentors are open. Insert
contact and wire into locator. Squeeze tool handles firmly and completely to insure a proper crimp. The
tool will not release unless the crimp indentors in the tool head have been fully actuated.
Contact Insertion
Contact Extraction
3. Press tool against contact shoulder and, with
firm and even pressure, insert wired contact and
t
ool tip into center contact cavity. A slight click may
be heard as metal retaining tines snap into place
behind contact shoulder.
2. Using proper plastic or metal insertion tool for
corresponding contact, position wire in tip of the tool
s
o that the tool tip butts up against the contact
shoulder.
1. Remove hardware from plug or receptacle and
s
lip over wire bundle in proper order for
reassembly.
1. Remove hardware from plug or receptacle
and slide hardware back along wire bundle.
2. Using plastic or metal extraction tool with proper
color code corresponding to contact size, place wire in
tool.
3. Insert tool into contact cavity until tool tip
bottoms against the contact shoulder, expanding
clip retaining tines.
6. Reassemble plug or receptacle.5. Fill any empty wire cavities with wire sealing plugs, and4. Hold wire firmly in tool and extract wired
contact and tool. Repeat operation for all
contacts to be extracted.
5. After all contacts are inserted, fill any empty
cavities with wire sealing plugs, Ressemble plug
or receptacle hardware.
4. Remove tool and pull back lightly on wire to make
sure contact is properly seated. Repeat operation with
remainder of contacts to be inserted, beginning with
the center cavity and working outward in alternating
rows.
Assembly Instructions
Contact Crimping
31
www.ittcannon.com
Dimensions shown in inches (mm)
Specifications and dimensions subject to change
Cannon KJL/KJ/KJA/KJB
MIL-DTL-38999 Series I, II, III Connectors
MIL-DTL-38999 Specifications
A
fter preloading to 3 pounds maximum, the force shall be applied at a rate of approximately 1 pound per second and maintained at full load for 5-10 sec-
o
nds. No damage to contacts or insert shall result nor shall the contacts be dislocated from their normal position in the connector more than 0.012 inch
under the given load. Failure to meet these requirements shall be cause for rejection.
The following excerpts are some of the parameter requirements of the MIL-DTL-3899 Specification.
F
or qualification testing, mating halves shall be coupled and uncoupled, measuring the torques necessary.The torques required to couple and uncouple
mating connector halves shall fall within the limits specifications as follows:
C
onnector halves shall be mated and unmated 250 times for Series II with ground fingers and 500 times for Series I and III at a rate not exceeding 300 cycles
p
er hour. The test may be performed by hand or by mechanical means, but the coupling ring shall be operated as in normal service. Failure to complete this
t
est because of mechanical malfunction shall be cause for rejection.
A
n insulation resistance test shall be performed on unmated connectors in accordance with MIL-STD-202, Method 302, Test condition B. Measurement shall
b
e made between three pairs of adjacent contacts and the shell. Failure to meet the minimum requirement of 50,000 megohms for Classes E, P, F, R, and T
shall be cause for rejection.
W
ired, mated connectors shall be subjected to the vibration test of MIL-STD-202, Method 214, Test Condition II, except that the duration shall be one hour
in each plane. Receptacles shall be mounted on the vibration fixture by normal means. All contacts shall be wired in a series circuit and 100-500 millamperes
of current shall be allowed to flow through the series circuit during vibration. Suitable means shall be employed to monitor the current flow and to indicate
any discontinuity of more than 1 microsecond. The wire bundle shall be damped to the nonvibrating points at least 8 inches from the rear of the connector.
C
urrent discontinuity of 1 microsecond or more, disengagement of the mated connectors, evidence of cracking, breaking, or loosening of parts shall be
cause for rejection.
W
ired mated connectors shall be subjected to one shock in each direction in each of three mutually perpendicular axes. The pulse shall be approximate half
sine wave of 300g ± 15% magnitude with a duration of 3 ± 1 milliseconds. Receptacles shall be mounted on a shock fixture by normal means. All contacts
shall be wired in a series circuit and 100-150 ma. of current shall flow through the series circuit during shock. Suitable means shall be employed to monitor
t
he current flow and to indicate any discontinuity of more than 1 microsecond. The wire bundle shall be clamped to fixed points at feast 8 inches from the
rear of the connector, Current discontinuity of 1 microsecond or more, disengagement of the mated connectors, evidence of cracking, breaking, or loosen-
ing of parts shall be cause for rejection.
Mated connectors shall be placed in a container of water at approximately 20ºC and placed in an altitude chamber. All wire ends shall be located within the
chamber and exposed to the chamber atmosphere, but not submerged. The exposed wire ends shall not be sealed. A quantity of salt, 5 percent by weight,
shall be added to make the water conductive. The chamber pressure shall then be reduced to approximately one inch of mercury and maintained for thirty
minutes. The chamber pressure shall then be slowly returned to atmospheric. This shall be considered one cycle. Two additional cycles shall be performed.
At the end of the last cycle, while the mated connectors are still submerged, the Insulation Resistance Test (room temperature), and the High Potential Test
(sea level voltages) shall be performed upon the same circuits. Failure to meet an insulation resistance minimum of 2,000 megohms or any evidence of dielec-
tric breakdown or -flashover shall be cause for rejection.
Unmated connectors shall be immersed fully in the applicable fluid specified below for 20 hours. After removal from the fluid, each connector shall
remain for one hour in free air at room temperature.
a.) Jet fuel JP-4 to MIL-J-5624 b.) Aircraft lubricating oil to MIL-L-9236
Unmated connectors and individual contact samples shall be subjected to the soft spray of MIL-STD-202, Method 101, Test Condition 8 (tin plated, Class Y
receptacles-24 hours). Immediately after exposure, the surfaces of the specimens shall be thoroughly washed in tap water and dried in a circulatory oven at
a temperature of 38 ±3ºC (100ºF) for a period of approximately 12 hours. Any exposure of basis metal as a result of this test, shall be cause for rejection.
(Series I and 11, finish B; Series III, class W). The wired assembled plugs and receptacles shall be mated and unmated 50 cycles at a rate of 300 cycles per
hour maximum. The mating and unmating shall be accomplished so that the plug and receptacle are completely separated during each cycle. The connec-
tors shall then be subjected to the salt spray test in accordance with method 1001 of MIL-STD- 1344. The connectors shall be tested for 452 hours mated
followed by 48 hours unmated. After the salt spray exposure the remaining number of durability cycles specified in 4.7.7 shall be completed.
Unmated receptacles shall be subjected to 10 cycles of thermal shock in the following manner:
The receptacle shall be suspended for 10 + 1 - 0 minutes in the center of a cold water both with a volume of approximately one cubic foot. No
d
imension of the bath shall be less than 10 inches. The water temperature shall not exceed 4ºC (39.20ºF)
The receptacle shall be suspended for 10 1 - 0 minutes in the center of a hot water bath with a volume of approximately one cubic foot. No
dimension of the bath shall be less than 10 inches. The water temperature shall be not less than 94ºC (201ºF).
The time of transfer from one bath to the other shall not exceed 5 seconds. At the end of the tenth cycle, the receptacle shall have the excess moisture shak-
en off and shall then be dried in a forced air oven at 66±5˚C for 15 ±1 minutes. Any evidence of damage resulting from this test shall be cause for rejection.
Contact Retention 4 5 19
Test
Description
Paragraph
Reference
R
equirements
C
oupling Torque 4 5 6
Durability 4 5 7
Insulation Resistance 4 5 9
Vibration 4 5 22
Shock 4 5 23
Thermal Shock 4 5 4
Altitude Immersion 4 5 8
Solvent Immersion 4 5 29
Corrosion 4 5 12
Dynamic Salt Spray 4 5 12 2
Temperature Durability 4 5 33
Step a
Step b
C
ontact Size 22M* 22D 22* 20 18
L
oads in Pounds ± 10% 10 10 10 15 25
T
orque
Shell Size Max. Min.
8
/9 82
1
0/11 12 2
1
2 16 2
1
3 16 2
Torque
S
hell Size Max. Min.
14 20 4
15 20 3
16 24 4
17 24 3
Torque
S
hell Size Max. Min.
18 28 5
19 28 3
20 32 6
21 32 5
Torque
S
hell Size Max. Min.
22 36 7
23 36 5
24 36 7
25 40 5
Wired rated connectors shall be subjected to the indicated anbient temperature for a period of 1,000 hours
Series I and II (finish A) 150 (302º F) Series I and II (finish B) 175 (347º F)
Series III (class W) 175 (347º F) All other finishes 200 (392º F)
+3º
-0ºC
+3º
-0ºC
+3º
-0ºC
+3º
-0ºC
* For reference only
PREVIOUS456789101112NEXT