Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

640252-1

Part # 640252-1
Description 045 POST CONT
Category CONTACT
Availability In Stock
Qty 174
Qty Price
1 + $0.02517
Manufacturer Available Qty
AMP
  • Shipping Freelance Stock: 174
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

MTA, CST-100 II, SL-156 and
AMP Economy Power
(EP) Connectors
NOT the LATEST
REVISION
2
© 1977, 1978, 1979, 1980, 1983, 1986,
1988, 1992, 1993, 1994, 1995, 1999,
2000, 2001, 2002, 2003 and 2005 by
Tyco Electronics Corporation.
All International Rights Reserved.
AMP, AMP-O-LECTRIC, AMP-O-MATIC,
AMPOMATOR, CERTI-CRIMP,
PRO-CRIMPER, MADISON CABLE and
TYCO are trademarks.
TEFLON is a trademark of E.I. DuPont
De Nemours and Company.
Other products, logos, and company
names mentioned herein may be
trademarks of their respective owners.
Introduction and Table of Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2, 3
Connector Selection Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3
.050 [1.27] Centerline Connectors
MTA-50 IDC Connectors and Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-10
Introduction and Wire-to-Board Mateability Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
IDC Connector Kits (Feed-Thru and Closed End)
Ribbon Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5, 6
Discrete Wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7, 8
Through-Hole Header Assemblies
Vertical and Right-Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Surface Mount Header Assemblies
Vertical and Right-Angle . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
.100 [2.54] Centerline Connectors
MTA-100 IDC Connectors and Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11-31
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Wire-to-Board Mateability Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12, 13
Connectors UL94V-2 and UL94V-0
Closed End with and without Polarizing Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 15
Feed-Thru with and without Polarizing Tab . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14, 15
LED Closed End and Feed-Thru UL94V-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 15
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16, 17
Posted Connectors Mateability Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18, 19
MTA-100 Posted Connectors (Wire-to-Wire) UL94V-2
Closed End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Feed-Thru . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20
Headers UL94V-0
Flat Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Narrow Flat Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Polarized Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Friction Lock Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24
Headers with Retention Peg Straight Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
High Profile Headers Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Polarized High Temperature, Straight and Right-Angle Posts . . . . . . . . . . . . . . . . .27
Friction Lock High Temperature, Straight and Right-Angle Posts . . . . . . . . . . . . . .28
Polarized Surface Mount, Straight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Friction Lock Surface Mount, Straight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .29
Shrouded Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
CST-100 II Crimp Contacts, Housings and Shrouded Headers . . . . . . . . . . . . . . . . . . . . . . . . .31, 32
.156 [3.96] Centerline Connectors
MTA-156 IDC Connectors and Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33-57
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33
Wire-to-Board Mateability Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34, 35
Connectors UL94V-2 and UL94V-0
Closed End with Locking Ramp, with and without Polarizing Tabs . . . . . . . . . . .36, 37
Closed End without Locking Ramp, with and without Polarizing Tabs . . . . . . . . .36, 37
Feed-Thru with Locking Ramp, with and without Polarizing Tabs . . . . . . . . . . . . .38, 39
Feed-Thru without Locking Ramp, with and without Polarizing Tabs . . . . . . . . . . .38, 39
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40-42
Posted Connectors Mateability Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43, 44
MTA-156 Posted Connectors (Wire-to-Wire) UL94V-2
Closed End . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
Feed-Thru . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .45
MTA-156 Headers UL94V-0
Flat Straight Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46
Flat Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .47
Friction Lock Straight Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .48
Friction Lock Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Polarized Lock Straight Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Polarized Lock Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .51
Friction Lock High Temperature, Straight Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . .52
Shrouded Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
MTA-156 Quad Connectors UL94V-0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54, 55
Closed End with Locking Ramp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Feed-Thru with Locking Ramp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .55
Introduction
This catalog has been designed
to assist you, our customer, iden-
tify products to satisfy your con-
nector needs for printed circuit
board headers, mass termination
connectors preloaded with con-
tacts, crimp-snap contacts and
housings, and card edge con-
nectors with preloaded contacts.
The list at right identifies by
centerline the types of product
available and is meant to be of
assistance to you in the product
selection process.
IDC
MTA-50
IDC
MTA-100
Crimp
CST-100 II
IDC
MTA-156
Catalog 82056 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 6-08 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 52-55-1106-0800 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 57-1-254-4444 UK: 44-208-420-8341
MTA, CST-100 II, SL-156 and
AMP Economy Power (EP) Connectors
Table of Contents
3
MTA-156 Card Edge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56, 57
Connectors UL94V-0
Closed End with and without Mounting Ears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Feed-Thru with and without Mounting Ears . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56
Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .57
SL-156 Crimp Connectors and Headers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58-62
Wire-to-Board Mateability Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58
Wire-to-Board Crimp Contacts and Keying Plugs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .59
Wire-to-Board Housings UL94V-0 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60
Housings with Through Board Latch UL94V-2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61
Housings and Contacts for Large Insulation Diameter (LID) Wire . . . . . . . . . . . . . . . . . .62
AMP Economy Power (EP) Connector System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63-69
.156 [3.96] Centerline Connectors
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .63
Crimp Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Plug Housings, Low-Profile . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64
Low-Profile Headers Straight and Right-Angle Posts . . . . . . . . . . . . . . . . . . . . . . . . . .65
Low-Profile Headers, High Temp. Straight and Right-Angle Posts . . . . . . . . . . . . . . .66
.200 [5.08] Centerline Connectors
Plug Housings and Straight and Right-Angle Post Headers . . . . . . . . . . . . . . . . . . . . . .67
.312 [7.92] Centerline Connectors
Low-Profile Headers Straight Posts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68
Single Connectors
1-Position Plug Housing and High-Profile Header Straight Post . . . . . . . . . . . . . . . . .69
MTA Wire Selection and Ribbon Cable Preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .70
IDC Ribbon Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71-74
MTA Wire Termination Flowchart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75
MTA Application Tooling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .76-79
Part Number Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80-82
Global Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .83
Center-
Contact Wire-to-
No. of
Wire Wire Current Voltage Operating
UL
Replace-
Product Name
line
Termin- Wire
Positions
Size Insulation Rating Rating Temp.
Flammability
ment Approvals
ation Option (AWG) Dia. Max. (A)** Max. (VAC) Range (°C) Contacts
.050" Centerline
MTA-50 IDC Connector .050
IDC Planned 2–28 30–26
.039*
1 30 –55 to +105 V-0 & V-2 No
Kits and Headers 1.27 0.99
.100" Centerline
MTA-100 Connectors .100
IDC Yes 2–28 28–22
.060*
5 250 –55 to +105 V-0 & V-2 Yes
and Headers 2.54 1.52
CST-100 II Contacts .100
Crimp Planned 2–28 26–22
.065
4 250 –55 to +105 V-0 Yes
and Housings 2.54 1.65
.156" Centerline
MTA-156 Connectors .156
IDC Yes 2–24 26–18
.095*
7 600 –55 to +105 V-0 & V-2 Yes
and Headers 3.96 2.41
Quad Connectors
.156
IDC No 2–12 22–18
.095*
12.5 600 –55 to +105 V-0 Yes
3.96 2.41
SL-156 Contacts .156
1–24; 2–10
.105
and Housings 3.96
Crimp No w/ through 24–18
2.67
10 250 –25 to +105 V-0 Yes
board latch
SL-156 Large Ins. Dia. (LID) .156
Crimp No 2–24 24–16
.112
10 250 –25 to +105 V-0 Yes
Contacts and Housings 3.96 2.84
.156", .200" and .312" Centerlines
.156
Crimp No 1–12 22–18
.118 8 (1 pos.)
250 –25 to +105 V-0 Yes
3.96 3.00 7.5 (2–12 Pos.)
AMP Economy Power .200
Crimp No 2–12 22–18
.118
250 –25 to +105 V-0 Yes
(EP) Connector System 5.08 3.00
7.5 (2–12 Pos.)
.312
Crimp No 2–5 22–18
.118
250 –25 to +105 V-0 Yes
7.92 3.00
7.5 (2–5 Pos.)
** When terminated one position at a time.
** Current Rating is application dependent.
Need more information?
Call Technical Support at the
numbers listed below.
Technical Support is staffed
with specialists well versed
in Tyco Electronics products.
They can provide you with:
Technical support
Catalogs
Technical Documents
Product Samples
Authorized Distributor
Locations
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
Connector Selection Guide
Crimp
SL-156
Crimp
AMP EP Connectors
Catalog 82056 Dimensions are in inches and Dimensions are shown for USA: 1-800-522-6752 South America: 55-11-2103-6000
Revised 6-08 millimeters unless otherwise reference purposes only. Canada: 1-905-470-4425 Hong Kong: 852-2735-1628
specified. Values in brackets Specifications subject Mexico: 52-55-1106-0800 Japan: 81-44-844-8013
www.tycoelectronics.com are metric equivalents. to change. C. America: 57-1-254-4444 UK: 44-208-420-8341
MTA, CST-100 II, SL-156 and
AMP Economy Power (EP) Connectors
Table of Contents (Continued)
1234567NEXT