Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

MS3100A24-10P

Part # MS3100A24-10P
Description CONN MIL-DTL-5015 CIRC PIN 7POS SLDR ST WALL MNT 7TERM -
Category CONNECTOR
Availability Out of Stock
Qty 0
Qty Price
1 + $49.50630



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

http://www.ddknet.co.jp
D/MS A/B Series
4
Specications and/or dimensions in this catalog are subject to change without notice.
 Your checking the latest specications with our drawings would be highly appreciated.
Insert Arrangement List
Front View of Pin Contact
Number of Contact
1 2
Insert
Arrangement
Insert Number 20-2 10SL-4 12S-3 14S-9 20-23 32-5
Contact Size 1-#0 2-#16 2-#16 2-#16 2-#8 2-#0
Service Rating
D A A A A D
Rated Current 150A 13A 13A 13A 46A 150A
Number of Contact
3
Insert
Arrangement
Insert Number 10SL-3 14S-1 14S-7 16S-5 16-10 18-5 18-21
Contact Size 3-#16 3-#16 3-#16 3-#16 3-#12 2-#12、1-#16 3-#12
Service Rating
A A A A A D A
Rated Current 13A 13A 13A 13A 23A
#12 : 23A
#16 : 13A
23A
Number of Contact
3
Insert
Arrangement
Insert Number 18-22 22-2 28-6 36-4
Contact Size 3-#16 3-#8 3-#4 3-#0
Service Rating
D D D
D(A)
A(BC)
Rated Current 13A 46A 80A 150A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
Contact Size Symbol
Service Rating INST A D E
Rated Voltage AC(r.m.s.) 200 500 900 1,250
Rated Voltage DC ・・・ 250 700 1,200 1,750
Contact Size ・・・・・・・・・・・ #16 #12 #8 #4 #0
MAX
Current
/Contact
13 23 46 80 150
#16 #12 #8 #4 #0
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
http://www.ddknet.co.jp
D/MS A/B Series
5
Specications and/or dimensions in this catalog are subject to change without notice.
 Your checking the latest specications with our drawings would be highly appreciated.
 Insert Arrangement List
Number of Contact
6
Insert
Arrangement
Insert Number 14S-6 18-12 20-17 20-22 36-3
Contact Size 6-#16 6-#16 5-#12, 1-#16 3-#8, 3-#16 3-#0, 3-#12
Service Rating
INST A A A D
Rated Current 13A 13A
#12 : 23A
#16 : 13A
# 8 : 46A
#16 : 13A
# 0 : 150A
#16 : 23A
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
Number of Contact
4
Insert
Arrangement
Insert Number 14S-2 18-4 18-10 20-4 22-10 22-22
Contact Size 4-#16 4-#16 4-#12 4-#12 4-#16 4-#8
Service Rating
INST D A D E A
Rated Current 13A 13A 23A 23A 13A 46A
Number of Contact
4
Insert
Arrangement
Insert Number 24-22 32-17 36-5
Contact Size 4-#8 4-#4 4-#0
Service Rating
D D A
Rated Current 46A 80A 150A
Number of Contact
5
Insert
Arrangement
Insert Number 14S-5 16S-8 18-11 18-20 32-1 32-2
Contact Size 5-#16 5-#16 5-#12 5-#16 2-#0、 3-#12 3-#4, 2-#16
Service Rating
INST A A A E(A), D E
Rated Current 13A 13A 23A 13A
# 0 : 150A
#12 : 23A
#4 : 80A
#16 : 13A
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
B
A
B
A
B
C
A
BC
A
B
C
D
A
B
C
D
D
C B
A
D A
BC
C B
D A
BC
A
AC
B
C B
A
Contact Size Symbol
Service Rating INST A D E
Rated Voltage AC(r.m.s.) 200 500 900 1,250
Rated Voltage DC ・・・ 250 700 1,200 1,750
Contact Size ・・・・・・・・・・・ #16 #12 #8 #4 #0
MAX
Current
/Contact
13 23 46 80 150
#16 #12 #8 #4 #0
http://www.ddknet.co.jp
D/MS A/B Series
6
Specications and/or dimensions in this catalog are subject to change without notice.
 Your checking the latest specications with our drawings would be highly appreciated.
Insert Arrangement List
Number of Contact
7
Insert
Arrangement
Insert Number 16S-1 20-15 22-28 24-2 24-10 28-10
Contact Size 7-#16 7-#12 7-#12 7-#12 7-#8 2-#4, 2-#8, 3-#12
Service Rating
A A A D A D(G), A
Rated Current 13A 23A 23A 23A 46A
#4 : 80A
#8 : 46A
#12 : 23A
Number of Contact
8 9
Insert
Arrangement
Insert Number 18-8 20-7 22-23 20-16 20-18 24-11
Contact Size 1-#12, 7-#16 8-#16 8-#12 2-#12, 7-#16 3-#12, 6-#16 3-#8, 6-#12
Service Rating
A
D(ABHG)
A(CDEF)
D(H) A A A A
Rated Current
#12 : 23A
#16 : 13A
13A 23A
#12 : 23A
#16 : 13A
#12 : 23A
#16 : 13A
#8 : 46A
#12 : 23A
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
Number of Contact
14
Insert
Arrangement
Insert Number 28-20 32-9
Contact Size 10-#12, 4-#16 2-#4, 12-#16
Service Rating
A D
Rated Current
#12 : 23A
#16 : 13A
#4 : 80A
#16 : 13A
Number of Contact
10 11 14
Insert
Arrangement
Insert Number 18-1 18-19 24-20 20-27 22-19
Contact Size 10-#16 10-#16 2-#12, 9-#16 14-#16 14-#16
Service Rating
A (BCFG)
INST
A D A A
Rated Current 13A 13A
#12 : 23A
#16 : 13A
13A 13A
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
B
D
E
A
C
D A
E
C B
F
B
D
A
E
F
E
A
B
D
C
BF
D
E C
C
B
D
E
F
G
B
D
E
F
G
C
A
B
C
D
E
F
G
H
I
H
J
A
K
C
D
E
P
L
B
J
H
N
G
F
M
EG
H
E
B
F G
KJ
NM
D
L
IH
C
A
C
C
Contact Size Symbol
Service Rating INST A D E
Rated Voltage AC(r.m.s.) 200 500 900 1,250
Rated Voltage DC ・・・ 250 700 1,200 1,750
Contact Size ・・・・・・・・・・・ #16 #12 #8 #4 #0
MAX
Current
/Contact
13 23 46 80 150
#16 #12 #8 #4 #0
PREVIOUS123456NEXT