Freelance Electronics Components Distributor
Closed Dec 25th-26th
800-300-1968
We Stock Hard to Find Parts

142-0701-201

Part # 142-0701-201
Description SMA COAXIAL CONNECTOR
Category CONNECTOR
Availability In Stock
Qty 3
Qty Price
1 + $1.47023
Manufacturer Available Qty
Military Spec
  • Shipping Freelance Stock: 2
    Ships Immediately
Military Spec
  • Shipping Freelance Stock: 1
    Ships Immediately



Technical Document


DISCLAIMER: The information provided herein is solely for informational purposes. Customers must be aware of the suitability of this product for their application, and consider that variable factors such as Manufacturer, Product Category, Date Codes, Pictures and Descriptions may differ from available inventory.

EEG Specific Features
www.ti.com
Figure 46. Scope Tab for Impedance Measurement at fDR/4 (DR = 4ksps)
7.3 External Calibration/Test Signals
ADS1299 generates a square wave test signal that can be used to check the functionality of the signal
chain (Refer to the datasheet for details). It also gives the user an option to provide external test signals
for calibration. For evaluation purposes with the EVM, the test signals can be provided directly to the
jumpers of the corresponding signals. SRB1 (pin2 of JP8), SRB2 (pin3 of JP7), BIASIN (Pin3 of JP6),
BIASREF (does not appear at a jumper, needs to be soldered to one side of R5).
7.3.1 Channel Inputs Disconnected
It may sometimes be required to provide a calibration or test signal to ADS1299 channel without the signal
being routed to the channel input pins (or electrodes). This can be accomplished by applying the positive
test signal to BIASIN pin and the negative test signal to BIASREF pin. The channel multiplexer must be
set as 010, BIASREF_INT bit in Config 3 register must be set to 0 to choose external BIASREF and
BIAS_MEAS bit in Config 3 must be set to 1. These multiplexer settings are illustrated in Figure 47.
40
EEG Front-End Performance Demonstration Kit SLAU443May 2012
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
www.ti.com
EEG Specific Features
Figure 47. Multiplexer Setting for Calibration with Electrode Disconnected
7.3.2 Channel Inputs Connected
It may sometimes be required to provide a calibration or test signal to ADS1299 device with the positive
input connected to the pin or electrode. This can be accomplished by connecting the positive test signal to
SRB2 pin and the negative test signal to SRB1 pin. The channel input multiplexer must be set for Normal
Electrode (000), SRB2 switch must be closed and SRB1 switch must be closed. This multiplexer setting is
illustrated in Figure 48.
41
SLAU443May 2012 EEG Front-End Performance Demonstration Kit
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
EEG Specific Features
www.ti.com
Figure 48. Multiplexer Setting with Positive Electrode Connected to Test Signal
If it is desired to have both the input pins connected during calibration or test, the following connections
must be made. The positive test signal must be tied to SRB2 pin and the negative test signal must tie to
BIASIN pin. The channel multiplexer must be set for 111 and the SRB2 switch must be closed. This
multiplexer setting is illustrated in Figure 49.
Figure 49. Multiplexer Setting with Both Electrodes Connected to Test Signal
42
EEG Front-End Performance Demonstration Kit SLAU443May 2012
Submit Documentation Feedback
Copyright © 2012, Texas Instruments Incorporated
PREVIOUS7891011121314151617181920NEXT